Example: barber

L7315:P4131:P44 (52.6) ACO Building Drainage

UniclassL7315:P4131:P44CI/SfB( )ACO Building DrainageDrainage systemsProduct catalogueSelecta Advanced Floor Drainage SystemsOur built environment is becoming ever morecomplex. Applications are becoming moresophisticated and the increasing pressure ofregulations and standards make achieving design,performance and financial goals ever tougher. ACO Building Drainage is a new concept within theACO Group. Our mission: to eliminate design risk,to reduce installed and life cost and to deliverexceptional finish and performance in everyproduct achieve this through three factors: High performance materials Design experience and project support Global manufacturing capacityOur global resources and fabrication capacity makeit possible for us to deliver best value, both with ourstandard products and with our bespoke is f

6 ACO Selecta - Floor Drainage ADVANCED FLOOR DRAINAGE SYSTEMS The role of the gully in preventative fire protection There is now a wealth of material to consider

Tags:

  Protection

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of L7315:P4131:P44 (52.6) ACO Building Drainage

1 UniclassL7315:P4131:P44CI/SfB( )ACO Building DrainageDrainage systemsProduct catalogueSelecta Advanced Floor Drainage SystemsOur built environment is becoming ever morecomplex. Applications are becoming moresophisticated and the increasing pressure ofregulations and standards make achieving design,performance and financial goals ever tougher. ACO Building Drainage is a new concept within theACO Group. Our mission: to eliminate design risk,to reduce installed and life cost and to deliverexceptional finish and performance in everyproduct achieve this through three factors: High performance materials Design experience and project support Global manufacturing capacityOur global resources and fabrication capacity makeit possible for us to deliver best value, both with ourstandard products and with our bespoke is further assured with quality systemsthat are in accordance with ISO Building Drainage s extensive portfolioincludes.

2 Stainless steel Modular Channel system Stainless steel EuroGully gully system Stainless steel and polymer composite access covers Biological Grease Management system Gravity Grease Separator system Anti-flood protection valves Stainless steel socketed pipe system Rainwater outlets for flat roofsACO Building Drainage is a division of ACOT echnologies plc and part of the worldwide ACO Group. The Group has sales in excess of 400million worldwide with production facilities in theUK, Germany, France, Switzerland, Denmark,Spain, Poland, Czech Republic, Australia and theUSA.

3 In total more than 3000 people are employedin 30 countries throughout the :01462 816666 Fax:01462 851490e-mail Building Drainage3 ACO SelectaACO SELECTA ADVANCED FLOOR Drainage SYSTEMSA dvanced Floor Drainage SystemsAdvanced floor gully introduction & key technologies4 The role of the gully in preventative fire protection6 Declaration of fire resistance performance7 Grating material choice8 Conservation of fuel and power9 Load class9 Application GuideThe application guide10 Features and BenefitsSelecta two-part gully12 Direct-couple gullies and rodding eyes13 ComponentsGratings and solid covers14 Gully body tops - 2 part system16

4 Gully bodies - 2 part system18 Accessory options - fire protection18 Gullies - direct couple19 Installation OverviewVertical gully with wet room gully top in ground floor wetroom with tiles22 Vertical gully with resin finish using two-part screed gully top in ground floor23 Vertical gully with sheet vinyl using two-part flexible floor clamp in ground floor24 Horizontal gully with resin finish using two-part screed gully top in ground floor 25with optional back inlet inflowVertical firestop gully in wetroom with tiles using two-part wetroom gully top 26in raised concrete floorVertical firestop gully with sheet vinyl using two-part flexible floor clamp 27in raised acoustic concrete floorHorizontal gully with resin finish using two-part screed gully top in raised floor28 Direct connection gully with sheet vinyl using direct-couple flexible floor gully top in ground floor29 Direct connection rodding access with resin finish using direct-couple screed gully top 30in ground floorVertical gully with tiles in raised concrete floor31 Operation and MaintenanceCleaning methods32 Standard

5 Specification ClausesStandard specification clauses34 Contents4 Advanced floor gully introduction & key technologiesACO Selecta - Floor DrainageADVANCED FLOOR Drainage SYSTEMSFire protection in a gully!ACO Building Drainage introduces the Selectarange of floor gullies. A range that has evolved ashave changes in the construction and functional performance combinewith modern aesthetics and sustainable to these features are patented systemsdesigned to augment other measures that reducerisk and aid compliance with the RegulatoryReform (Fire Safety) resistance performance: EI 120-U/UHigh performance stainless steel or copper alloy gratingsSelecta provides choice: from high performance stainless steel designs through traditional copper alloy to lowcost economy options.

6 Our sophisticated manufacturing techniques enable off-the-shelf options without bodyAccessories such as sealed rodding eyes can beused in stand alone or with the gully as waterproofing systemsIdeal for concrete, tile and natural stone,Selecta also integrates with flexible sheetflooring as well as the most recent tankingmaterials for wetrooms. Advanced floor gully introduction & key technologiesACO Selecta - Floor DrainageADVANCED FLOOR Drainage SYSTEMS5 Fire protection and cost reductionTime and cost of installation can be enhanced through use ofthe ACO Fit-In sleeve system - ideal for slab penetrations, Fit-Inremoves the need for mortar and reduces build time, as wellas providing extra fire fire cartridgeTested in accordance with BS EN 1366.

7 The morestringent replacement for BS476 ensures performanceeven in the most severe fire situations, reducingsubstantially smoke transfer to other Building floorlevels as well as reducing oxygen paths that feed and manufactured to BS EN 1253 Remarkably few systems available on themarket meet the requirements of thisstandard; specify confidently as factorsranging from self cleaning ability thoughadequate dpm flange membrane clampingarea are Selecta - Floor DrainageADVANCED FLOOR Drainage SYSTEMSThe role of the gully in preventative fire protectionThere is now a wealth of material to considerregarding fire safety.

8 The Regulatory Reform (FireSafety Order) 20051aims to reduce both hazardand risk, where risk is the likelihood andconsequence of Building Regulations2incorporate designguidance where, given certain Building types,compartmentation is used to reduce firepropagation. The efficacy of such schemes isdependent on both integrity and insulation. In the case of fire, Integrity prevents the passage offlame and hot gas from the exposed to unexposedside, whereas insulation restricts temperature risebelow specified levels3. Preserving the integrity andinsulation performance of a separating element isproblematic if gullies are used for other thanground floor Drainage .

9 In effect, they present an'open ended' pipe penetration when the water trapis depleted and connecting pipework has beendestroyed. This worst case scenario is assumed inthe test protocol followed by devices, such as gullies, are tested inaccordance with BS EN 13664, and classified inaccordance with BS EN 135015(see references on page 7).With a Drainage gully, the underside is consideredmore critical as fire spread is more likely from lowerfloors. Attention must therefore be paid to thedesign of the gully body and its installation. Whilst measurements are taken at the grating viathermocouples, these upper parts of the system do not determine system performance.

10 The gully body is cast iron and is sited within athermally insulating pre-formed concrete jacket toprovide effective fire containment and limitthermal transmittance. protection is augmented byan intumescent cartridge that sits in the outletspigot. This material expands at approximately150 C, closing off the system in combination, water trap depletion isdramatically reduced and integrity and insulationmaintained. An additional, though unmeasuredbenefit, is the reduced passage of smoke. 7 ACO Selecta - Floor DrainageADVANCED FLOOR Drainage SYSTEMSRisk proportionatemeasuresThe Publicly Available Specification - PAS 796comments on 'risk-proportionate' fire this context unnecessary expenditure isprecluded, but where appropriate, furtherprotection can be included if ACO Selecta system is designed to offeranother tool for the specifier to incorporate intotheir design where appropriate.


Related search queries