Example: stock market

DUR-O-WAL TRUSS - Construction Midwest, Inc.

DUR-O-WAL TrussProduct Information/Submittal SheetDUR-O-WAL TRUSSP roduct Description DUR-O-WAL TRUSS is a prefabricated reinforcement especiallydesigned for embedment in the horizontal mortar joints ofmasonry. It is manufactured in 10 ft. lengths. DUR-O-WALtruss consists of two or more parallel longitudinal deformedrods weld-connected to a continuous diagonally orientedcross rod which forms a TRUSS at least one longi-tudinal side rod for each bed spacing ofthe side rods is approximately 2 inches less than the nominalthickness of the wall or wythe in which the reinforcement isplaced. DUR-O-WAL TRUSS is manufactured in accordance withUniform Building Code Standard UBC 21-10 andACI530/ASCE6/TMS402 Building Code Requirements forMasonry Uses DUR-O-WAL TRUSS reinforcment is used in a number of applica-tions to improve the performance of masonry walls.

®DUR-O-WAL TRUSS Warranty Seller makes no warranty of any kind, express or implied, except that

Tags:

  Rust, Dur o wal truss

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of DUR-O-WAL TRUSS - Construction Midwest, Inc.

1 DUR-O-WAL TrussProduct Information/Submittal SheetDUR-O-WAL TRUSSP roduct Description DUR-O-WAL TRUSS is a prefabricated reinforcement especiallydesigned for embedment in the horizontal mortar joints ofmasonry. It is manufactured in 10 ft. lengths. DUR-O-WALtruss consists of two or more parallel longitudinal deformedrods weld-connected to a continuous diagonally orientedcross rod which forms a TRUSS at least one longi-tudinal side rod for each bed spacing ofthe side rods is approximately 2 inches less than the nominalthickness of the wall or wythe in which the reinforcement isplaced. DUR-O-WAL TRUSS is manufactured in accordance withUniform Building Code Standard UBC 21-10 andACI530/ASCE6/TMS402 Building Code Requirements forMasonry Uses DUR-O-WAL TRUSS reinforcment is used in a number of applica-tions to improve the performance of masonry walls.

2 Some are: To control shrinkage cracking To provide principal horizontal reinforcement in engineered masonry walls To bond masonry wythes together in composite and cavity walls.* To reinforce stack bond masonry. To bond intersecting walls.* Tri-Rod or Double Side Rod TRUSS should not be used with insulated cavity DUR-O-WAL recommends mill galvanized (.10 oz. psf) for interior applications. DUR-O-WAL recommends hot dipped galvanized ( ) for exterior applications. Also available in Class 1, Class 3 or stainless steel. Check local building code for specification.* Interior application where high moisture content is involved (locker rooms, food centers), hot dip galvanized Tests show that continuous reinforcement improves the perfor-mance of walls by providing: Crack Control Greater elasticity Butt welded single plane Construction Higher ductility High bond with deformed side wires Better resistance to rain penetrationSpecifications All DUR-O-WAL wire products are made with wire conform-ing to the ASTM STANDARD SPECIFICATION for COLDDRAWN STEEL for CONCRETE REINFORCEMENT,ASTM A82 and ASTM STAINLESS STEEL material conforms toASTM STANDARD SPECIFICATIONS A580, TYPE and Placement Place joint reinforcement directly on masonry and placemortar over wire to form bed joint.

3 * Minimum ounces of zinc coating per square foot of uncoated wire surface1 BOCA and SBCC Codes allow this finish for interior Basic wire acquires rust in warehousing, transit, and job site storage. Therefore, DUR-O-WAL does not assume any responsibility for rusted material.** Specify and insist on DUR-O-WAL ! DUR-O-WAL will certify on request that its hot dip galvanized (ASTM A153) product will have a minimum of oz. of zinc per square foot-33% more corrosion protection than minimum standard does not recommend using epoxy coating forjoint reinforcement, anchors or TRUSS Increased horizontal flexual strength More Construction economy Lower life cycle costsReference SpecificationsFinishCoating*ASTM A82 (for cold drawn steel wire)Brite Basic2uncoatedRegular Mill Galvanized ASTM A 641 1 Mill Galvanized ounce zinc coatingASTM A641-Class 1 Mill Galvanized ounce zinc coatingASTM A641-Class 3 Mill Galvanized ounce zinc coatingASTM A153-Class B-2**Hot ounce zinc coatingCustomer Service Aurora, IL (800) 323-0090 Folcroft, PA (800) 368-2035 Birmingham, AL (800) 821-9296 Phoenix, AZ (800)

4 235-0024 Technical Service Email: Fax-On-Demand: (800) 254-8958 DUR-O-WAL TRUSSW arranty Seller makes no warranty of any kind, express or implied, except thatthe goods sold under this agreement shall be of the standardquality of seller, and buyer assumes all risk and liability resulting fromthe use of the goods, whether used singly or in combination withother goods. Seller neither assumes nor authorizes any person toassume for seller any other liability in connection with the sale or useof the goods sold, and there is no oral agreement or warrantycollateral to or affecting this The information contained in this publication does not constitute anyprofessional opinion or judgement and should not be used as asubstitute for competent professional determinations.

5 Each constructionproject is unique and the appropriate use of this product is theresponsibility of the engineers, architects and other professionalswho are familiar with the specific requirements of the Corners and tees A complete line of prefabricated corner and tee sections areavailable in all design types and finishes. It is necessary todesignate corners as inside or outside when using Trirod orDouble design Method To determine the amount of steel supplied by DUR-O-WALT russ use the following formula:As= A Piecex 12 SpacingExample:The area supplied by No. 8 Std. TRUSS at 16 in. x 12 = is less than that required taken from table above( ).No. 8 std. TRUSS at 8 in. would x 12= .072 exceeds the minimum cavities are insulated check for effect or differential movement.*Effective area of DUR-O-WAL TRUSS , Trirod and Double includes side rods plus on allowance for the tensile resistance of diagonal crossrods which is equal to the diagonal cross rod area times the cosine of the angle between the diagonal cross rod and side 7/03 DUR-O-WAL TRUSSMINIMUM AREA OF HORIZONTAL STEEL REQUIRED TO SATISFY CODE REQUIREMENTSN ominal Wall Thickness (in)4 6 8 10 12 14 16 18 20 22 24 Gross Area in2 area of steel in2 x Gross AreaHorizontal ,198 Required in2/ft*Compare area of steel required with area supplied by DUR-O-WAL TRUSS .

6 Use calculation method given TABLED esign TypesWeight ClassificationsWall WidthsEffective Areas (in2)*/pieceand wire sizesSingleComposite orWytheCavityCompositeSingle ClassSideCrossOverallOverall (for 3 (for 4 (for6 (for 8 (for 10 (for 12 (for 13 (for 14 (for 16 (for 18 (for 20 WidthWidthWidthwall)wall)wall)wall)wall) wall)wall)wall)wall)wall)wall) ,4, TRUSSW ,10,12 Extra3/16 ,14, or 20 StandardNo. ,10,123,4,6 Not made ,14,168,103 ,4 ,6 wallsDUR-O-WAL TRUSS TrirodExtra3/16 ,20,22or 12 Not made ,4 ,6 ,12,13, 3,4,6,Not made for, ,16,18, 8,10,3 ,4 ,6 ,8 wallsDUR-O-WAL TRUSS DoubleExtra3/16 ,22,or 12 Not made ,4 ,6 ,8 wallsSales and Services Centers 625 Crane StreetAurora, IL 60505(800) 323-0090 Fax: (630) 898-13783 Horne DriveFolcroft, PA 19032(800) 368-2035 Fax: (610) 534-72061401 Meadowcraft RoadBirmingham, AL 35215(800) 821-9296 Fax: (205) 856-09654810 South 40th Street, Suite 3 Phoenix, Arizona 85040(800) 235-0024 Fax: 602-431-9667