Transcription of EPC-D-F-ATS Spec Sheet - UL 924 Inverters and …
1 LVS, Inc. 2555 Nicholson Street, San Leandro, CA 94577-4216 Phone: 510-352-9600 1-800-982-4587 Fax: :Model No.:Comments:The Model EPC-D-F-ATS is a single zone, silent emergency transfer control with universal dimming capability. It can be used with 2 and 3-wire line voltage dimming systems, as well as 0-10V, DALI, and Lutron EcoSystem. The EPC-D-F-ATS allows emergency lighting to be dimmed with normal lighting during normal times. In the event of a utility power interruption, the EPC-D-F-ATS will automatically transfer designat-ed emergency fixtures from the dimming control to the emergency power source and bring them to full brightness, regardless of whether the dimming system is in operation or turned of the EPC-D-F-ATS include designat-ed dimmable emergency luminaires in public places such as auditoriums, restaurants, conference rooms, theaters.
2 And Surge ProtectionIncludes field-selectable Automatic Testing & Fire Alarm Interface optionsTriple Interlock (electrical, mechanical, and time delay) maximizes safety and reliability of EPC-D-F-ATS , by eliminating arcing and the potential for phase to phase shorts between separate power sources during & Emergency Power Indicator LED sSlim, attractive universal mount enclosure allows flush, surface, panel, and box front mounted test switchOversized 50A rated relay contacts allow high inrush loads to be used safely and reliably.
3 Tested at over 5000 with both inverter and generator systems, normally-on and normally-off Voltage Dimming5 YEARWARRANTY0-10V DimmingUL UL1008 LISTEDCUSLED COMPATIBILEEPC-D-F-ATSB ranch Circuit Emergency Lighting Transfer Switch for 2, 3, and 4-Wire Dimmable LoadsSPECIFICATIONSORDERING INFORMATIONADDITIONAL RESOURCES LVS, Inc. 2555 Nicholson Street, San Leandro, CA 94577-4216 Phone: 510-352-9600 1-800-982-4587 Fax: LINE DRAWINGWIRING DIAGRAMEPC-D-F-ATSI nstallation InstructionsTheory of Operation & FAQA lternative Wiring Diagrams Terms & Conditions/Warranty InformationEMERGENCY HOT#2 NORMAL PANELEMERGENCYPOWERTESTSWITCHUTILITYPOWE R20A#10 Normal Light (optional)EMERGENCY PANEL OR INVERTER20 ANORMAL HOTNORMAL NEUTRALEMERGENCY NEUTRAL#4#3 Emergency LightNote.
4 Emergency Light is also called N/E Light or Normal/Emergency Light by many specifiers#12#13#11#1#7#9#5#6#8 DESIGNATEDEMERGENCYLIGHTSNORMAL ROOM LIGHTSUL 1008 Transfer SwitchOr EquivalentNormal Utility PowerEmergency Power Source(Neutral Not Shown)EPC-D-F-ATSNORMAL PANELN ormal Utility PowerEMERGENCYPANEL OR INVERTER$EPC-D-F-ATSDNote: dimmer may be a stand-alone dimmer, multi-zone dimmer (such as Grafik Eye), or central dimming panel. One EPC-D-F-ATS is required per dimming zone with emergency : Typical 2-Wire Dimming shown.
5 Please see Installation Instructions for 3-wire and 0-10V Wiring INPUTLOAD RATINGBALLAST LOAD RATINGINCANDESCENT LOADWARRANTYEPC-D-F-ATS120V-277V120V - 277V (16A)16A Magnetic/16A Electronic1920W (120V) / 4432W (277V)5 Year Replacement WarrantyELECTRICALMOUNTINGRATINGSHIPPING WEIGHT/ COLORTEMPERATUREFLUSH MOUNTED SIZEBODY SIZE4-11/16 Back-up Box, no plaster ring requiredUL94V-018 oz. / White32 F - 140 F (0 C - 60 C)6 x 6 x 4 x 4 x MECHANICALFire Alarm Tie- Fire Alarm Jumper (see additional resources)