RCM 700 Sureclose Actuators

The Failsafe Electro/HydraulicActuator consists of a singleacting spring return actuator forfail safe operation, mountedelectric motor, hydraulic pumpand reservoir. The actuator ismodified for hydraulic servicewhich includes a bleeder topurge air from the system. Thepump is driven by a totallyenclosed fan cooled single phasemotor. In the event of a powerloss, the valve will automaticallygo to the fail position (counter-clockwise or clockwise) by meansof the springs in the actuator. TECHNICAL DATA SHEETELECTRICRCM 700 Sureclose Actuators Increased or reduced speeds M-1 handwheel manual overrides Explosion proof motors, switches and solenoid valves Wash down motors Heater and thermostats Single phase 120 VAC, 220 VAC, 3-phase voltages 4-20MA DC 0 10 VDC, or 1-5 VDC for modulation 4-20MA DC feedback Other voltages available on requestOPTIONSNOTE:We prefer to quote actuator to valve mounting hardware in all casessince the power unit reservoir and actuator are provided as a Control Inc.

ab c rci 230sr 11.51 7.7 --rci 240sr 11.51 7.7 7.7 rci 250sr 13.36 11.2 --rci 260sr 13.36 11.2 11.2 rci 270sr 17.02 20.1 --rci 230, 250, 270 rci 240, 260

Tags:

  Rcm 700 sureclose, Sureclose

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of RCM 700 Sureclose Actuators

1 The Failsafe Electro/HydraulicActuator consists of a singleacting spring return actuator forfail safe operation, mountedelectric motor, hydraulic pumpand reservoir. The actuator ismodified for hydraulic servicewhich includes a bleeder topurge air from the system. Thepump is driven by a totallyenclosed fan cooled single phasemotor. In the event of a powerloss, the valve will automaticallygo to the fail position (counter-clockwise or clockwise) by meansof the springs in the actuator. TECHNICAL DATA SHEETELECTRICRCM 700 Sureclose Actuators Increased or reduced speeds M-1 handwheel manual overrides Explosion proof motors, switches and solenoid valves Wash down motors Heater and thermostats Single phase 120 VAC, 220 VAC, 3-phase voltages 4-20MA DC 0 10 VDC, or 1-5 VDC for modulation 4-20MA DC feedback Other voltages available on requestOPTIONSNOTE:We prefer to quote actuator to valve mounting hardware in all casessince the power unit reservoir and actuator are provided as a Control Inc.

2 Box 355 North Kingstown, RI 02852 Phone 401-294-1400 Fax401-294-3388 Email FEATURES Springs equal to 100 PSI torque output Limit switch to shut down pump when valve reaches open/closed position Two additional switches for open/close indication Painted carbon steel mounting brackets unless specified otherwise 4-20MA positioners in either weather or explosion proof verisionsTORQUE OUTPUT*Larger torques available on request POAHYDRAULIC PRESSURESPRINGTypeOpens CCW RotationCloses CW Rotation0 60 90 90 30 0 RCI 230 SRH-100/M404830310400635309460 RCI 240 SRH-100/M40416656658401330620930 RCI 250 SRH-100/M4042745975124019909301415 RCI 260 SRH-100/M404553021252655407019903010 RCI 265 SRH-100/M404714927823767633731354375 RCI 270 SRH-100/M4041115442905310841039805105 RCI 280 SRH-100/M4042212588501106017170832012480 RCI 88

3 SRH-100/M4044425017700221253429516595248 70 RCI 90 SRH-100/M4044425017257212403363015930243 37 RCI 100 SRH-100/M4048850035400442506858733187497 37 Pump: Gear-Type pump, capacity gallons/minute M404 Model. Opening and closing stroke times at +70 F ambient 230 SRH-100/M404 ..3 5 secondsRCI 240 SRH-100/M404 ..5 10 secondsRCI 250 SRH-100/M404 ..10 15 secondsRCI 260 SRH-100/M404 ..15 20 secondsRCI 265RH-100 35 secondsRCI 270 SRH-100/M404 ..35 50 secondsRCI 280 SRH-100/M404 ..75 100 secondsRCI 88 SRH-100/M404 ..250 300 secondsRCI 90 SRH-100/M404 ..150 200 secondsRCI 100 SRH-100/M404 ..250 300 secondsNOTE: Failure and power stroke times can be altered through variations of the standard DATA SHEETRCM 700 SurecloseTECHNICAL DATAPump PressureFactory set between 100 and 140 PSIM otor1/2 HP, 3450 RPM, 115/230/60, singlephaseOperating Temperature Range-5 F to 130 FOil TypeMobil DTE 24 or equivalentAB CRCI 230, 250, 270 RCI 240, 260 RCI 280 TECHNICAL DATA SHEETRCM 700 SurecloseRemote Control Inc.

4 Box 355 North Kingstown, RI 02852 Phone 401-294-1400 Fax401-294-3388 Email RCI 88-SRRCI 100-SR


Related search queries