Example: dental hygienist

AC AMMETERS & AC VOLTMETERS - beimeter.com

ANALOG PANEL METER SELECTION GUIDE. AC AMMETERS & AC VOLTMETERS . Please find values for each squares below from 1 to 9 (7, 8 & 9 are optional). ER. ON. TU. PE. LA. TI. TY. E. NC. SI. AL. E. E. NG. YL. NG. PO. ME. ZE. NT. GN. RA. ST. NO. SI. RA. NS. ME. R. SI. TE. ER. ER. E. E. IO. T. T. VE. AL. AL. IN. PU. PU. T. T. T. MO. ME. ME. PO. OP. SC. SC. IN. IN. X X X X X X X X- X. 1 2 3 4 5 6 7 8 9. 1. Meter Style 7. Scale Nomenclature P: Panel Board UAA: AC Micro-Amperes S: Surface MAA: AC Milli-Amperes Fill 7 & 8. W: Window AAA: AC Amperes if scale is KAA: AC Kilo-Amperes different from input signal. 2. Meter Size VVA: AC Volts 2: KVA: AC Kilo-Volts Skip otherwise. 3: CYL: Cycles 4: RPM: RPM. PFM: Power Factor 3. Movement Type WAT: Watts I: Iron Vane VAR: Vars 4.

Brighton Electronics, Inc. www.beimeter.com Ph. 503-624-7116 16732 SW 72nd Ave. Portland, OR 97224 sales@beimeter.com Fax 503-624-0207 …

Tags:

  Voltmeter, Ammeter, Ac ammeters amp ac voltmeters

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of AC AMMETERS & AC VOLTMETERS - beimeter.com

1 ANALOG PANEL METER SELECTION GUIDE. AC AMMETERS & AC VOLTMETERS . Please find values for each squares below from 1 to 9 (7, 8 & 9 are optional). ER. ON. TU. PE. LA. TI. TY. E. NC. SI. AL. E. E. NG. YL. NG. PO. ME. ZE. NT. GN. RA. ST. NO. SI. RA. NS. ME. R. SI. TE. ER. ER. E. E. IO. T. T. VE. AL. AL. IN. PU. PU. T. T. T. MO. ME. ME. PO. OP. SC. SC. IN. IN. X X X X X X X X- X. 1 2 3 4 5 6 7 8 9. 1. Meter Style 7. Scale Nomenclature P: Panel Board UAA: AC Micro-Amperes S: Surface MAA: AC Milli-Amperes Fill 7 & 8. W: Window AAA: AC Amperes if scale is KAA: AC Kilo-Amperes different from input signal. 2. Meter Size VVA: AC Volts 2: KVA: AC Kilo-Volts Skip otherwise. 3: CYL: Cycles 4: RPM: RPM. PFM: Power Factor 3. Movement Type WAT: Watts I: Iron Vane VAR: Vars 4.

2 Pointer Position L: Zero Left 8. Scale Range C: Zero Center A: 1 G: 15 OG: 120 W: 750 ZP: 3000. R: Zero Right B: 2 H: 20 P: 150 X: 800 ZQ: 4000. C: 3 I: 25 Q: 200 Z: 1000 ZR: 5000. CC: 4 J: 30 QC: 208 ZC: 1200 ZS: 5250. 5. Input Signal D: 5 K: 40 QL: 240 ZF: 1400 ZT: 6000. AAA: AC Amperes DG: 6 L: 50 R: 250 ZH: 1500 ZU: 7500. VVA: AC Volts DL: 7 LT: 60 S: 300 ZL: 1600 ZV: 8000. E: 8 M: 75 T: 400 ZM: 1800 ZZ: 10000. 6. Input Range EY: 9 N: 80 U: 500 ZN: 2000. * ammeter Ranges F: 10 O: 100 V: 600 ZO: 2500. A: 1 F: 10 J: 30. B: 2 G: 15 K: 40. C: 3 H: 20 L: 50 9. Options D: 5 I: 25 (Skip if none selected). * voltmeter Ranges BD: Blank Dial L: 50 OG: 120 S: 300 MD: Mirror Dial LT: 60 P: 150 T: 400 SB: Semi-Blank Dial M: 75 Q: 200 U: 500 SD: Silicon Damping N: 80 QL: 240 V: 600 HD: Heavy Damping O: 100 R: 250 MT: Special Mounting R: RoHS.

3 Brighton Electronics, Inc. Ph. 503-624-7116. 16732 SW 72nd Ave. Portland, OR 97224 Fax 503-624-0207. Copyright 2012 Brighton Electronics, Inc. ANALOG PANEL METER SELECTION GUIDE. DC AMMETERS & DC VOLTMETERS . Please find values for each squares below from 1 to 9 (7, 8 & 9 are optional). RE. ON. TU. To find Part Number, PE. LA. TI. TY. E. NC. SI. AL. E. E. NG. fill each X's (1 through 9): YL. NG. PO. ME. ZE. NT. GN. RA. ST. NO. SI. RA. NS. ME. R. SI. TE. ER. ER. E. E. IO. T. T. VE. AL. AL. IN. PU. PU. T. T. T. MO. ME. ME. PO. OP. SC. SC. IN. IN. X X X X X X X X- X. 1 2 3 4 5 6 7 8 9. 1. Meter Style 7. Scale Nomenclature P: Panel Board UAA: AC Micro-Amperes MAA: AC Milli-Amperes S: Surface AAA: AC Amperes Fill 7 & 8. W: Window KAA: AC Kilo-Amperes if scale is VVA: AC Volts different 2.

4 Meter Size KVA: AC Kilo-Volts from input signal. UAD: DC Microamperes 1: MAD: DC Milliamperes Skip otherwise. 2: AAD: DC Amperes 3: MVD: DC Millivolts VVD: DC Volts 4: ETM: Hours 5: (Surface & Window Only) HTZ: Hertz CYL: Cycles 3. Movement Type RPM: RPM. PFM: Power Factor P: Pivot & Jewel WAT: Watts T: Taut Band 8. Scale Range 4. Pointer Position Select the value from 6. Input Range . L: Zero Left C: Zero Center 9. Options R: Zero Right (Skip if none selected). BD: Blank Dial 5. Input Signal MD: Mirror Dial UAD: DC Microamperes SB: Semi-Blank Dial MAD: DC Milliamperes SD: Silicon Damping AAD: DC Amperes HD: Heavy Damping MVD: DC Millivolts MT: Special Mounting VVD: DC Volts R: RoHS. 6. Input Range * ammeter Ranges (50 A ~50A DC). * voltmeter Ranges (15mV~600V DC).

5 AA: C: 3 EY: 9 I: 25 LL: 55-65 QC: 208 W: 750 ZO: 2500. A: 1 CC: 4 F: 10 J: 30 LP: 58-62 QL: 240 X: 800 ZP: 3000. AC: CX: 4-20 FD: 10-50 JX: 32-48 LT: 60 R: 250 Z: 1000 ZQ: 4000. AF: D: 5 FN: 12 K: 40 M: 75 S: 300 ZC: 1200 ZR: 5000. AH: DG: 6 FX: 12-14 KD: 45-55 N: 80 SL: 350-450 ZF: 1400 ZS: 5250. AM: DL: 7 G: 15 KL: 45-65 O: 100 SP: 380-420 ZH: 1500 ZT: 6000. AX: 1-5 DN: GG: 16 KP: 48-52 OG: 120 T: 400 ZL: 1600 ZU: 7500. B: 2 E: 8 H: 20 L: 50 P: 150 U: 500 ZM: 1800 ZV: 8000. BF: EX: 8-16 HX: 24-32 LD: 50-70 Q: 200 V: 600 ZN: 2000 ZZ: 10000. Brighton Electronics, Inc. Ph. 503-624-7116. 16732 SW 72nd Ave. Portland, OR 97224 Fax 503-624-0207. Copyright 2012 Brighton Electronics, Inc. ANALOG PANEL METER SELECTION GUIDE. AC FREQUENCY METERS & ELAPSED TIME METERS.

6 FREQUENCY METERS. Please find values for each squares below from 1 to 7 (7 is optional). ON. PE. TI. TY. SI. AL. E. E. YL. NG. PO. ZE. NT. GN. ST. SI. RA. NS. ME. R. SI. TE. ER. ER. IO. T. T. VE. IN. PU. PU. T. T. T. MO. ME. ME. PO. OP. IN. IN. X X X X X X- X. 1 2 3 4 5 6 7. 1. Meter Style 5. Input Signal P: Panel Board HTZ: Hertz S: Surface W: Window 6. Input Range KD: 45-55. 2. Meter Size KL: 45-65. 2: LL: 55-65. 3: SP: 380-420. 4: . 3. Movement Type 7. Options P: Pivot & Jewel (Skip if none selected). T: Taut Band BD: Blank Dial SD: Silicon Damping 4. Pointer Position HD: Heavy Damping L: Zero Left MT: Special Mounting R: RoHS. ELAPSED TIME METERS. SPECIFICATION. Surface or Panel Board 3 . Range: 0 to 99, (Non-resettable reading recycles to 0.)

7 Power: 120V AC, 60Hz (105V to 130V AC). Optional 230V AC, 60Hz Overload: Times for 2 Hours 2 Times for 5 Seconds Operating Temperature: -20 to 65 C. S3 ETM. P3 ETM. Brighton Electronics, Inc. Ph. 503-624-7116. 16732 SW 72nd Ave. Portland, OR 97224 Fax 503-624-0207. Copyright 2012 Brighton Electronics, Inc.