Transcription of ELECTRICAL SYSTEM ACCUPRO MVOLT Ballast …
1 CONTRACTOR SELECT / DOWNLIGHTING ACCUPROC atalog NumberNotesTypeContractor Select Electronic Ballast OptionACCUPRO MVOLT Instant StartFEATURES & SPECIFICATIONSNEMA Premium Normal Ballast factor: circuit temperature is 0 F for 32W lamps; 60 F for energy-saving T8 voltage: 120-277; 50Hz or Listed Class P; CSA SYSTEMB allast shall be instant shall contain auto-restart circuitry to restart lamps without a reset of shall operate input voltages 120-277, with variations of +/- 10% at 50Hz or shall be a high-frequency electronic type, and operate lamps at a frequency above 42kHz to minimize interference with infrared devices, eliminate visible flicker and avoid Article Surveillance shall have power factor greater than for primary shall have minimum Ballast factor of for primary current crest factor shall be or less, in accordance with lamp manufacturer shall have a less than 10% Total Harmonic Distortion (THD).
2 Ballast shall have a class A sound shall have a minimum starting temperature of 0 F for 32W T8 lamps, and 60 F for energy-saving T8 shall tolerate sustained open circuit and short circuit output conditions without shall not contain any shall comply with ANSI Category A for Transient shall comply with ANSI shall comply with FCC part 18 non-consumer equipment for EMI/RFI (conducted and radiated). Ballast shall be labeled "NEMA Premium". Ballast shall be manufactured in facility certified to ISO 9001 shall have a five-year history of producing electronic ballasts for the North American shall be Underwriters Laboratory listed, Class P, Type 1 Outdoor, and CSA shall carry a two-year warranty from the date of subject to change without MATRIXSTANDARD 4' 32 WATT LAMP OPERATION1 Input Input Input Model Min.
3 Power Ballast Wattage Current Current Number2 # Lamps BEF@277 factor factor 120/277 (A) 120V (A) 277V THD A* 132-IP-UNV 1 Lamp > > 30/28 <10% A* 232-IP-UNV 2 Lamp > > 56/55 <10% A* 332-IP-UNV 3 Lamp > > 85/83 <10% A* 432-IP-UNV 4 Lamp > > 112/109
4 <10%ENERGY SAVING 4' 28 WATT LAMP OPERATION Input Input Input Model Min. Power Ballast Wattage Current Current Number2 # Lamps BEF@277 factor factor 120/277 (A) 120V (A) 277V THD A* 132-IP-UNV 1 Lamp > > 26/25 <10% A* 232-IP-UNV 2 Lamp > > 50/50 <10% A* 332-IP-UNV 3 Lamp > > 75/75 <10% A* 432-IP-UNV 4 Lamp > > 97/97
5 <10%ENERGY SAVING 4' 25 WATT LAMP OPERATION Input Input Input Model Min. Power Ballast Wattage Current Current Number2 # Lamps BEF@277 factor factor 120/277 (A) 120V (A) 277V THD A* 132-IP-UNV 1 Lamp > > 23/23 <10% A* 232-IP-UNV 2 Lamp > > 44/44 <10% A* 332-IP-UNV 3 Lamp > > 69/66 <10% A* 432-IP-UNV 4 Lamp > > 90/88
6 <10%(1) Also operates 17W 2' lamps (2) Asterick (*) represents series number or letter ACCUPRO CONTRACTOR SELECT / FLUORESCENT One Lithonia Way Conyers, GA 30012 Phone: Fax: 770-981-8191 2011 Acuity Brands Lighting, Inc.
7 All rights reserved. Rev. 03/31/11 Electronic Ballast OptionACCUPRO 120V Instant StartACCUPRO MVOLT AND 120V, Electronic Ballast Option, Instant Start FEATURES & SPECIFICATIONSN ormal Ballast factor: circuit temperature is 0 F for 32W lamps; 60 F for energy-saving T8 voltage: Listed Class P; CSA SYSTEMB allast shall be instant shall contain auto-restart circuitry to restart lamps without a reset of shall be a high-frequency electronic type, and operate lamps at a frequency above 40kHz to minimize interference with infrared devices, eliminate visible flicker and avoid Article Surveillance shall have power factor greater than for primary shall have minimum Ballast factor of for primary current crest factor shall be or less, in accordance with lamp manufacturer shall have a class A sound shall have a minimum starting temperature of 0 F for 32W T8 lamps.
8 And 60 F for energy-saving T8 shall tolerate sustained open circuit and short circuit output conditions without shall not contain any shall comply with ANSI Category A for Transient shall comply with ANSI shall comply with the limits of FCC Part 18C Class B (Residential) and Class shall be manufactured in facility certified to ISO 9001 shall have a five-year history of producing electronic ballasts for the North American shall be Underwriters Laboratory listed, Class P, Type 1 Outdoor, and CSA shall carry a two-year warranty from the date of subject to change without MATRIX32 WATT LAMP OPERATION1 Input Input Model Min.
9 Power Ballast Wattage Current Number2 # Lamps BEF3 factor factor 120/277 (A) 120V THD AP-RC-232IP 1 Lamp > > 37 <15% AP-RC-232IP 2 Lamp > > 58 <10% AP-RC-432IP 3 Lamp > > 93 <10% AP-RC-432IP 4 Lamp > > 108 <10%Notes1 Also operates 32W-U lamps.
10 17W 2' lamps, 25W 3' lamps, and 30W and 28W energy-savings Asterisk (*) represents series number or BEF, Ballast efficacy factor, = ( Ballast factor x 100) input wattage.