Steam turbine anti-motoring (reverse power) Rotor damage risk

This document is AXA Matrix RC March 2015 VersionFor further information or specific questions contact: turbine anti-motoring (reverse power ) Rotor damage riskMotoring can happen when a turbine s Steam supply is lost whilst the generator is still coupled to a network (or operated in parallel with another generator). The generator will then become a synchronous motor and will actually drive the Steam turbine with the potential for significant mechanical reverse power protection device should be inserted within the generator protection scheme, in compliance with Institute of Electrical and Electronics Engineers standard IEEE Guide for AC Generator Protection (Section ).EXPERIENCE FEEDBACKTechC@RE machinery breakdownGENERATOR TURBINEELECTRICAL CURRENTGENERATOR damage TO TURBINEELECTRICAL CURRENTS team turbine are used to drive synchronous alternators for electricity damage to turbineMechanical repair of Steam turbine15 daysStart of acceptance test5 daysBlack out on public network2 hoursTurbine running as a synchronousmotor20 minutesBreakdown duration: 1 monthReturn of powerThis document is AXA Matrix RC March 2015 VersionFor further information or specific questions contact: turbine a

This document is AXA Matri RC March ersion For further information or specic uestions contact: techcareaacscom Steam turbine anti-motoring (reverse power) Rotor damage risk

Tags:

  Reserve, Turbine, Power, Reserve power

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Steam turbine anti-motoring (reverse power) Rotor damage risk

1 This document is AXA Matrix RC March 2015 VersionFor further information or specific questions contact: turbine anti-motoring (reverse power ) Rotor damage riskMotoring can happen when a turbine s Steam supply is lost whilst the generator is still coupled to a network (or operated in parallel with another generator). The generator will then become a synchronous motor and will actually drive the Steam turbine with the potential for significant mechanical reverse power protection device should be inserted within the generator protection scheme, in compliance with Institute of Electrical and Electronics Engineers standard IEEE Guide for AC Generator Protection (Section ).EXPERIENCE FEEDBACKTechC@RE machinery breakdownGENERATOR TURBINEELECTRICAL CURRENTGENERATOR damage TO TURBINEELECTRICAL CURRENTS team turbine are used to drive synchronous alternators for electricity damage to turbineMechanical repair of Steam turbine15 daysStart of acceptance test5 daysBlack out on public network2 hoursTurbine running as a synchronousmotor20 minutesBreakdown duration: 1 monthReturn of powerThis document is AXA Matrix RC March 2015 VersionFor further information or specific questions contact: turbine anti-motoringEXPERIENCE FEEDBACKF acts1.

2 A large paper mill has a Steam turbo-generator connected to the public network or can be operated in island In order to increase its power output, the Steam turbo-generator was refurbished/ upgraded in The upgrade focused on mechanical components, as the electrical components were overhauled/ upgraded some years earlier by another contractor. 4. During re-commissioning; the sequence of power disconnection and power reconnection to the public network induced motoring of the Steam turbine . Aggravating factors Operator waited more than 15 minutes before calling an electrical technician to open the main generator breaker. Lack of a dedicated electrical technician during the commissioning/test recommendations Annual testing of reverse power ( anti-motoring ) protection. It should provide backup for sequential tripping schemes.

3 Control the presence of safety chains, test safety valves, surge valves on Steam supply, pressure/ level devices on lubrication system, bearing temperature, over speed protection, vibration monitoring, earth fault, loss of field, over voltage/current instrumentation, including anti-motoring . Annual testing and calibration is recommended. Operators should be trained on identifying generator motoring conditions and on subsequent shutdown/isolation causesTotal loss amount: several millions euros (shaft, bearings, blades, packing seals)Failure of protection relay on anti-motoring chain (partially wired)Lack of bearings lubrication causing significant wear/vibration to Rotor shaft and thermal stresses Generator running as synchronous motorClient agreement on testing without environment analysisLack of formalized procedures for testing protection systems on re-start - Photos : Shutterstock, 2000 Geothermal Education Office, NRC