Transcription of CRONO S-PID 50 - Pompe infusionali
1 USER GUIDEA mbulatory infusion pumpCRONO S-PID 50 NEW MODELM anual code: MAN 01/EN/01 CRONO S-PID 50 Publication date: 02/13 CAN Medical TechnologyVia Cuorgn 42/a 10098 Rivoli (TO) Italy Tel.+39 011 9574872 - Fax +39 011 - 01/EN/01 CRONO S-PID 50 02/13 SECTION 1 Symbols and Page 8 SECTION 2 Introduction .. Page 9 WARNING: PRECAUTIONS FOR USE .. Page Page 10 SECTION 3 Intended use .. Page 11 Pump description .. Page 13 Infusion Page 13 Technical characteristics .. Page 14 SECTION 4 Equipment supplied .. Page 16 SECTION 5 Pump parts .. Page 17 Control buttons .. Page Page 18 Liquid crystal display (LCD) .. Page 19 Low battery indicator.
2 Page 21 Battery replacement .. Page 22 SECTION 6 Settings lock .. Page 24 SECTION 7 Errors and anomalies .. Page 25 Infusion set occlusion .. Page 28 Post-occlusion Page 28 CONTENTS6 MAN 01/EN/01 CRONO S-PID 50 02/13 CONTENTSSECTION 8 Factory settings .. Page 29 SECTION 9 Quick reference .. Page 30 SECTION 10 Pump Page 33 Pump settings when inserting Page 34 Pump settings sequence with the pump OFF condition .. Page 35 Setting of end of infusion acoustic signal .. Page 36 Setting of the number of infusion sites .. Page 37 Setting the partial volume .. Page 39 Settings in ON condition .. Page 40 Setting the delivery time.
3 Page 41 Setting the flow rate .. Page 42 Switching on the pump .. Page 43 The pump in ON condition .. Page 43 Priming the infusion line .. Page 44 End of the infusion .. Page 46 Withdrawing the pusher .. Page 47 Switching off the pump .. Page 49 Displaying the Page 49 Resetting the infusion trip Page 50 SECTION 11 Reservoir parts .. Page 51 Luer Lock Cap functions .. Page 51 Infusion set .. Page 52 Infusion set parts .. Page 52Y-SET .. Page 527 MAN 01/EN/01 CRONO S-PID 50 02/13 Multiple infusion set .. Page 53 Multiple infusion set parts .. Page 53 Preparation of the reservoir and insertion into the pump .. Page 54 Insertion of the reservoir into the pump.
4 Page 55 Pump configuration images for infusions at multiple sites .. Page 57 Infusion Page 58 Preparing for the infusion .. Page 58 SECTION 12 How to use the supplied accessories .. Page 61 SECTION 13 Maintenance .. Page 63 GENERAL WARNINGS .. Page 63 Storage .. Page 63 Disposal .. Page 63 Expected pump life .. Page 63 Support .. Page 64 Guarantee .. Page 65 Declaration of conformity .. Page 67 APPENDICESA ppendix 1: Page 69 Appendix 2: Page 71 Appendix 3: Page 73 Appendix 4: Page 79 Appendix 5: Page 80 Appendix 6: Page 81 Appendix 7: Page 83 Appendix 8: Page 868 MAN 01/EN/01 CRONO S-PID 50 02/13To assist you in using the manual, the following symbols and conventions have been used:Triangle containing an exclamation markThis WARNING icon indicates something that must always be taken into consideration for safe use of the icon indicates NOTES containing additional information or useful tips about the use of the AND CONVENTIONSSECTION 1 This manual is divided into 5 parts:Part 1 (red).
5 Sections 1 to 7, general information, technical specifications and 2 (blue): sections 8 to 10, which describe the functions of the CRONO S-PID 50 3 (orange): section 11, which describes the reservoir, the preparation and insertion of the reservoir into the pump, the infusion sites and the preparation for an 4 (purple): sections 12 and 13, giving general warnings and a description of the accessories supplied, as well as discussing maintenance, disposal and support. It also details the guarantee and the declaration of : Pages 69 to 86. Flashing symbolThe graphic symbol shown in the manual above the pictures of the pump display, indicates that the information below it is 01/EN/01 CRONO S-PID 50 02/13 INTRODUCTIONT hank you for having chosen the ambulatory infusion pump, model.
6 CRONO S-PID manual has been prepared to enable you to make the best use of the CRONO S-PID 50 pump, supplying information on the settings, safe use and maintenance of the any of the information is not clear, or if you have any doubts or questions, please contact the Customer Support Service of CAN use of the pump, or the failure to follow the instructions and warnings provided in this manual could cause serious instructions provided herein are exclusively with respect to the ambulatory infusion pump, model: CRONO S-PID 50 and are intended for use by the medical and paramedical personnel who need to set up the pump initially, and subsequently by patients who are capable of managing their therapy autonomously, or persons who are caring for pump has a settings locking system (see page 24) which stops the settings from being modified by accident.
7 The information relating to the locking/unlocking of the settings lock is supplied at the back of this manual on a plastic purpose of the settings lock is to avoid accidental or unauthorised modification of the selected parameters. If it is considered inappropriate that the patient should be aware of how to unlock the settings lock, the doctor and/or other person who is assisting the patient should not supply this instructions in this manual are essential for the safe and correct use of the pump. You are advised to read the whole manual before starting to use the device and to keep the manual handy for future pump does not need to be installed, tested and/or activated.
8 CAN reserves the right to modify the hardware and software specifications described in this manual at any time and without 210 MAN 01/EN/01 CRONO S-PID 50 02/13 NOTES CAN reserves the right to modify and/or update this manual at any time and without notice. In order to make this manual as complete and accurate as possible, please report any errors or omissions to the following e-mail address: 2 INFORMATIONFor further information about the CRONO S-PID 50 pump, contact:Customer Support ServiceCAN Medical TechnologyVia Cuorgn , 42/a 10098 Rivoli (Turin) - ItalyTel. + Fax + : e-mail: pump is not recommended for independent use by patients who are unable to follow and understand the instructions supplied in this manual or unable to perform the basic operations and the regular maintenance of the.
9 PRECAUTIONS FOR USE11 MAN 01/EN/01 CRONO S-PID 50 02/13 SECTION 3 The CRONO S-PID 50 ambulatory infusion pump is designed for the subcutaneous infusion of immunoglobulins and drugs in disclaims all responsibility for the administration of drugs by other manufacturer holds itself liable for the safety and the correct functioning of the device, provided that it is used in accordance with these instructions and that any required repairs and/or modifications are carried out exclusively by the said use of incorrect settings and/or incomplete understanding of the operational functionality and of the alarms could cause serious harm to the using the pump, evaluate whether its use is appropriate for the need and for the patient, paying close attention to the following aspects.
10 - The technical specifications of the pump- The infusion sets which will be used- Whether you will be using multiple tube sets and clamps in the infusion line- The cognitive and psycho-physical condition of the respect to the clinical procedural aspects, which are the responsibility of the medical or paramedical personnel, the above list is supplied for example purposes only and is not device must be used:- Under the control of a doctor- Adopting appropriate procedures and adequate measures when dealing with patients who could suffer serious consequences (injury or death) in the event of accidents and/or breakdowns which cause an interruption of the administration of the USE12 MAN 01/EN/01 CRONO S-PID 50 02/13Do not prime the infusion line when it is connected to the patient, because this could cause an overdose of the beginning an infusion, inspect the infusion line to ensure there are no folds, clamps, or other occlusions in the line, and expel any air level of precision and amount of time needed to detect an occlusion could differ from the values indicated in this manual, depending on the type of catheter.