Example: dental hygienist

E97-811-18 LAN-90 Process Control View (PCV

Process Cont rol andAutomation Solutionsfrom Elsag Bailey Group E97-811-18 LAN-90 Process Control view (PCV ) and TCP-LinkSoftware user s guide (Software Release )WARNING notices as used in this instruction apply to hazards or unsafe practices that could result inpersonal injury or notices apply to hazards or unsafe practices that could result in property highlight procedures and contain information that assists the operator in understanding theinformation contained in this MANUALSDO NOT INSTALL, MAINTAIN, OR OPERATE THIS EQUIPMENT WITHOUT READING, UNDERSTANDING,AND FOLLOWING THE PROPER Elsag Bailey INSTRUCTIONS AND MANUALS; OTHERWISE, INJURY ORDAMAGE MAY FREQUENCY INTERFERENCEMOST ELECTRONIC EQUIPMENT IS INFLUENCED BY RADIO FREQUENCY INTERFERENCE (RFI). CAU-TION SHOULD BE EXERCISED WITH REGARD TO THE USE OF PORTABLE COMMUNICATIONS EQUIP-MENT IN THE AREA AROUND SUCH EQUIPMENT.

LAN-90® Process Control View (PCV®) and TCP-Link Software Users Guide (Software Release 5.2) WARNING notices as used in this instruction apply to hazards or unsafe practices that could result in personal injury or death. ... LAN-90 Process Control View (PCV) ...

Tags:

  Guide, User, Control, Process, View, S guide, Process control view

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of E97-811-18 LAN-90 Process Control View (PCV

1 Process Cont rol andAutomation Solutionsfrom Elsag Bailey Group E97-811-18 LAN-90 Process Control view (PCV ) and TCP-LinkSoftware user s guide (Software Release )WARNING notices as used in this instruction apply to hazards or unsafe practices that could result inpersonal injury or notices apply to hazards or unsafe practices that could result in property highlight procedures and contain information that assists the operator in understanding theinformation contained in this MANUALSDO NOT INSTALL, MAINTAIN, OR OPERATE THIS EQUIPMENT WITHOUT READING, UNDERSTANDING,AND FOLLOWING THE PROPER Elsag Bailey INSTRUCTIONS AND MANUALS; OTHERWISE, INJURY ORDAMAGE MAY FREQUENCY INTERFERENCEMOST ELECTRONIC EQUIPMENT IS INFLUENCED BY RADIO FREQUENCY INTERFERENCE (RFI). CAU-TION SHOULD BE EXERCISED WITH REGARD TO THE USE OF PORTABLE COMMUNICATIONS EQUIP-MENT IN THE AREA AROUND SUCH EQUIPMENT.

2 PRUDENT PRACTICE DICTATES THAT SIGNS SHOULDBE POSTED IN THE VICINITY OF THE EQUIPMENT CAUTIONING AGAINST THE USE OF PORTABLE COM-MUNICATIONS Process UPSETSMAINTENANCE MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL AND ONLY AFTER SECURINGEQUIPMENT CONTROLLED BY THIS PRODUCT. ADJUSTING OR REMOVING THIS PRODUCT WHILE IT ISIN THE SYSTEM MAY UPSET THE Process BEING CONTROLLED. SOME Process UPSETS MAYCAUSE INJURY OR information contained in this document is subject to change without Bailey, its affiliates, employees, and agents, and the authors and contributors to this publication specif-ically disclaim all liabilities and warranties, express and implied (including warranties of merchantability andfitness for a particular purpose), for the accuracy, currency, completeness, and/or reliability of the informationcontained herein and/or for the fitness for any particular use and/or for the performance of any material and/or equipment selected in whole or part with the user of/or in reliance upon information contained of materials and/or equipment is at the sole risk of the user of this document contains proprietary information of Elsag Bailey, Elsag Bailey Process Automation, and isissued in strict confidence.

3 Its use, or reproduction for use, for the reverse engineering, development ormanufacture of hardware or software described herein is prohibited. No part of this document may bephotocopied or reproduced without the prior written consent of Elsag PrefaceThis manual applies to LAN-90 PCV Software Release and TCP-Link options. It providesgeneral information and specific instructions on ConfiguringclassCONNECT/DDE and TCP-Link manual should be used as: A reference guide for system engineers and techniciansresponsible for installing and configuring classCONNECT/DDE and TCP-LINK software. An operation guide for Process Control operators and otherusers on using manual assumes the reader has a sound knowledge ofLAN-90 PCV. I-E97-811-18B List of Effective Pages Total number of pages in this instruction is 59, consisting of the following:Page DatePrefaceOriginalList of Effective PagesOriginaliii through viiOriginal1-1 through 1-5 Original2-1 through 2-3 Original3-1 through 3-6 Original4-1 through 4-21 Original5-1 OriginalA-1 through A-7 OriginalB-1 through B-6 OriginalIndex-1 through Index-3 OriginalWhen an update is received, insert the latest changed pages and dispose of the super-seded : On an update page, the changed text or table is indicated by a vertical bar in the outer mar-gin of the page adjacent to the changed area.

4 A changed figure is indicated by a vertical bar in theouter margin next to the figure caption. The date the update was prepared will appear beside thepage of ContentsPageI-E97-811-18B iiiSECTION 1 - INTRODUCTION ..1-1 OVERVIEW ..1-1 REQUIREMENTS ..1-2 Hardware Requirements ..1-3 CONTENT OF THIS USED IN THIS MANUAL ..1-4 RELATED 2 - INSTALLATION ..2-1 BEFORE INSTALLING ..2-1 INSTALLING QNX THE LAN-90 PCV TCP-LINK OPTION ..2-2 INSTALLING classCONNECT/DDE ..2-2 SECTION 3 - CONFIGURATION ..3-1 OVERVIEW ..3-1 ENABLING COMMUNICATIONS IN LAN-90 PCV ..3-1 Setting The Host TCP/IP Address ..3-1classCONNECT/DDE SETUP OPTIONS ..3-3 Selecting a Time Zone ..3-3 Time-Zone Examples ..3-4 Changing the DDE Server Name ..3-5 CONFIGURING THE NET AGENT ..3-5 Port ..3-5 Host List .. UP PROGRAM GROUPS ..3-6 SECTION 4 - OPERATION ..4-1 OVERVIEW.

5 4-1 GENERAL INFORMATION ..4-1 THE NET AGENT ( ) ..4-1 Overview ..4-1 Net Agent Status Window ..4-1 Logging In to LAN-90 PCV ..4-3 Connecting to LAN-90 PCV Hosts ..4-4 THE SERVER MONITOR ( ) ..4-4 THE PCV DDE SERVER ( ) ..4-5 Error Indication ..4-5 DDE SYNTAX ..4-6 Server Name ..4-6 Topic Name ..4-6 Explicit Time TOPIC ..4-7 TAGLIST TOPIC ..4-8 Retrieving Multiple Fields Through the Same Link ..4-9 Retrieving Historical Data ..4-10 TIMEREF TOPIC - SYMBOLIC TIME REFERENCES ..4-13 UPDATING TAG DATA AND PERFORMING Control ..4-16iv I- E97-811-18 BTable of Contents (continued)Page SECTION 4 - OPERATION (continued)SYSTEM 4-16 EXAMPLES .. 4-17 THE TAG WIZARD ( ) .. 4-18 Servers, Tags and Fields .. 4-19 Historical Data .. 4-20 Copying to the Clipboard .. 4-20 SAMPLES .. 4-21 SECTION 5 - GLOSSARY ..5-1 GLOSSARY .. 5-1 APPENDIX A - ENHANCED DATA COLLECTION SYSTEM (EDCS) OVERVIEW.

6 A-1 INTRODUCTION .. A-1 EVENT DATA VS. SAMPLED DATA .. A-1 FILTERING AND STATISTICS .. A-1 STORAGE .. A-3 DATA A-3 APPENDIX B - B-1 ODBC SETUP ..B-1 List of of a Network Using TCP-Link and classCONNECT/DDE .. Configuration Menu .. Options .. Agent Status Window .. a Host for Wizard Window (in RealTime Update Mode) .. Class Configuration Screen .. Data Flow .. Events to Periodic Samples .. Calculations for a Hypothetical Series of Events .. Administrator icon .. Install Drivers Dialog .. Data Data Source Dialog .. Driver Selection .. Install Drivers Data Source Setup .. Source Configuration .. B-5vi of Tables Zone Examples .. DDE Error Indicators .. Data Retrieval Methods .. Messages for Historical Data Retrieval Requests .. 4-13I-E97-811-18B viiSafety SummarySPECIFICCAUTIONSBy enabling Remote Login, you are granting users on the TCP/IPnetwork (who have a valid LAN-90 PCV user name, password, andprivileges) access to operations that may change the operating con-ditions in your LAN-90 PCV system.

7 This includes remote (from cli-ent) access to Control functions such as motor start/stop andcontroller set point and output changes. Therefore, make sure thatwhen you enable this option, you are careful in assigning LAN-90 PCV accounts and permissions. (p. 3-1)Care must be used when assigning an IP address to a node on aTCP/IP network. Avoid duplicating IP addresses. Note that some IPaddresses are reserved , and that addresses in different rangeswill sometimes have different behaviors. Consult the documentationthat came with your TCP/IP software for more details. (p. 3-2)Extreme caution should be used when embedding Control -typefunctionality into spreadsheet macros. Make sure that any macrosyou set up are protected from improper use, and well documentedas to their functionality. It is not a good idea to have Control -typemacros execute automatically when a spreadsheet is opened,because someone browsing through spreadsheet files may acci-dentally invoke a Control operation.

8 (p. 4-16)viii I-E97-811-18B Trademarks and Registrations Registrations and trademarks in this document include: AppleRegistered trademark of Apple Computer, Inc. classCONNECT/DDET rademark of Elsag Bailey Process Automation Elsag BaileyRegistered trademark of Elsag Bailey Process Automation. EthernetTrademark of Xerox Corporation. INFI 90 Registered trademark of Elsag Bailey Process Automation. LAN-90 Registered trademark of Elsag Bailey Process Automation. MacIntoshRegistered trademark of Apple Computer, Incorporated. ODBCT rademark of the Microsoft Corporation. PCVR egistered trademark of Elsag Bailey Process Automation. QNXR egistered trademark of QNX Software Systems. TCP-LINKT rademark of Elsag Bailey Process Automation. WindowsRegistered trademark of the Microsoft Corporation. WordperfectRegistered trademark of the Wordperfect 1 - 1 SECTION 1 - INTRODUCTIONOVERVIEWThe classCONNECT/DDE product is a collection of softwarethat allows useful data to be exchanged between Process mon-itoring consoles in the LAN-90 PCV environment, and desktopcomputers running one of the Microsoft Windows family ofoperating systems.

9 Using this product, you can incorporate livedata into reports and spreadsheets, set up using your favoritethird party package, and actually watch the values change inreal-time. Alternatively, historical information collected byLAN-90 PCV can be viewed. This information can be incorpo-rated into any of the many Microsoft Windows applicationsthat support the DDE data communication standard, such asMicrosoft Excel , Microsoft Word for Windows, and WordPer-fect , with no more effort than a few clicks of the desired, systems can be configured that actually allow datato be sent back to the LAN-90 PCV system from the MicrosoftWindows computer system. This can be used to change inter-nal PCV values, or even perform some Control functions. Ofcourse, if you want to perform these types of functions you willhave to be pre-qualified through the standard LAN-90 PCVpassword protection mechanism, which classCONNECT/DDEinterfaces shown in Figure 1-1, classCONNECT/DDE works in con-junction with the LAN-90 PCV TCP-Link software provides the services necessary on the LAN-90 PCVconsole to communicate with the classCONNECT/DDE soft-ware modules.

10 Communications between these two packagesis done via a standard TCP/IP Local Area Network interfaceover Ethernet .classCONNECT/DDE conforms to the DDE standards as setout by Microsoft. This allows you to work with a large numberof applications from numerous vendors. The classCONNECT/DDE server has been tested with both Microsoft Excel andMicrosoft Word using the examples included in the applications that claim to support DDE do not support itfully, however, and therefore may not function as well as theyshould. While we cannot guarantee that any other applicationwill function as flawlessly, through our Professional Servicesprogram we offer whatever level of support you require to inte-grate your applications with classCONNECT/DDE. Please con-tact your local Elsag Bailey sales office for information aboutour Professional Services program.


Related search queries