Example: confidence

CE DECLARATION OF CONFORMITY MONARCH ... - …

Pocket Laser Tach 200(PLT200)Tachometer / Rate Meter / Totalizer / Timer15 Columbia Drive Amherst, NH 03031 USAP hone: (603) 883-3390 Fax: (603) 886-3300E-mail: ManualSAFEGUARDS AND PRECAUTIONSL aser hazards Eye injury from beam - Do not look into the direct or refl ected beam; can cause eye injury up to 25 ft ( m) away. Visual interference (glare) with pilots and drivers - Interferes with vision up to 525 ft (160 m) away. Can be a distraction up to 1 mile ( km) away. NEVER point any laser towards aircraft or vehicles; it is unsafe and use guidanceClass 2 lasers are considered safe for accidental eye exposure. Do not look or stare into beam. Do not aim at aircraft. This is not a toy. Always supervise and follow all instructions in this manual carefully, and retain this manual for future not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifi cations instrument is not user serviceable.

1 1.0 OVERVIEW The Pocket Laser Tach 200 is a precision hand-held multifunction Tachometer, Ratemeter, Totalizer and Timer. It is programmable to display

Tags:

  Declaration, Declaration of conformity, Conformity

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of CE DECLARATION OF CONFORMITY MONARCH ... - …

1 Pocket Laser Tach 200(PLT200)Tachometer / Rate Meter / Totalizer / Timer15 Columbia Drive Amherst, NH 03031 USAP hone: (603) 883-3390 Fax: (603) 886-3300E-mail: ManualSAFEGUARDS AND PRECAUTIONSL aser hazards Eye injury from beam - Do not look into the direct or refl ected beam; can cause eye injury up to 25 ft ( m) away. Visual interference (glare) with pilots and drivers - Interferes with vision up to 525 ft (160 m) away. Can be a distraction up to 1 mile ( km) away. NEVER point any laser towards aircraft or vehicles; it is unsafe and use guidanceClass 2 lasers are considered safe for accidental eye exposure. Do not look or stare into beam. Do not aim at aircraft. This is not a toy. Always supervise and follow all instructions in this manual carefully, and retain this manual for future not use this instrument in any manner inconsistent with these operating instructions or under any conditions that exceed the environmental specifi cations instrument is not user serviceable.

2 For technical assistance, contact the sales organization from which you purchased the order to comply with EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE): This product may contain material which could be hazardous to human health and the environment. DO NOT DISPOSE of this product as unsorted municipal waste. This product needs to be RECYCLED in accordance with local regulations, contact your local authorities for more information. This product may be returnable to your distributor for recycling - contact the distributor for Instrument s Limited Warranty applies. See for Registration and Extended Warranty coverage available online at LaserMax. output power: <1 milliwattWavelength: 650 nanometers (visible light)Beam Divergence: 18 milliradianOutput: Continuous (CW)Laser hazard classifi cation: Class 2 Manufacturer: MONARCH Instrument15 Columbia DriveAmherst, NH 03031 USAC ountry of Origin: USAC ontact info: with 21 CFR and except for deviations pursuant to Laser Notice No.

3 50 of June OF CONTENTSTABLE OF OVERVIEW .. FEATURE LOCATIONS .. LCD DISPLAY INPUT / OUTPUT .. PREPARATION FOR MEASUREMENT .. Non-Contact Preparation .. Direct Contact Preparation .. Connecting External Sensors .. TAKING MEASUREMENTS .. Non-Contact Measurements .. Direct Contact Measurements .. TACH ometer Mode .. TACH ometer TACH ometer RATE Mode .. RATE Setup .. RATE Operation .. TOTAL izer Mode .. TOTAL izer Setup .. TOTAL izer Operation .. TIMER Mode .. TIMER Setup .. TIMER Operation .. BATTERIES .. SPECIFICATIONS .. CLEANING .. OPTIONS OVERVIEWThe Pocket Laser Tach 200 is a multifunction Tachometer, Ratemeter, Totalizer and Timer. It is programmable to read in English or Metric units. An input socket accepts remote sensing devices and an output socket allows for pulse output to external indicating devices.

4 The PLT200 can be tripod mounted and Locked-On for accurate and continuous operation. This tachometer also stores minimum, maximum and last measurement in FEATURE LOCATIONSMin / Scroll Down arrowStart / Reset buttonMax / Scroll Up arrowLCD displayMenu / Select and Lock-on buttonBattery compartmentAVOID EXPOSURE - LASER BEAM IS EMITTED FROM THIS APERTUREO utput socketInput socketBelt clipTripod mounting bushing (underside) LCD DISPLAY SYMBOLSOn Target Indicator. Blinks on whenever there is an input signal. Will appear to be solid on at higher Battery icon. Indicates that the batteries are low and need to be Ten icon. Indicates that the value shown is ten times that which is Indicator. Red laser is on when this indicator is icon. Indicates that the unit is Locked on and making continuous measurements (Lock mode).

5 INPUT / OUTPUTO utput socket (q)Input socket (p)Input: Accepts remote sensor or Remote Contact Assembly (RCA). 1/8 ( ) stereo phone : 1 pulse per revolution TTL output on internal operation. Pulse repeater with external sensors. 1/8 ( ) mono phone Connector Detail (Stereo plug)Output Connector Detail (Mono plug)Signal Input+3V Out to SensorCommon (GND)Common (GND)+3V Out to SensorSignal InputPulse OutputCommon (GND)Common (GND)Pulse PREPARATION FOR Non-Contact PreparationFor Internal operation (Red laser) or External operation using optional Remote Optical Sensor (ROS-Red LED). Direct Contact PreparationFor External operation ONLY using optional Remote Contact Assembly (RCA).1. Clean ShaftAs small as 1/8 wide on side or radius edge 2. Apply 1/2 square T-5 Refl ective tapeFor Small Shafts: Select and install contact option:1.

6 Contact Tip (Convex tip shown. Use Concave tip for small shafts.)Align fl ats Connecting External SensorsPlug sensor into Input socketTighten screw securely into fl at on with pin in shaft fully seated in slot. Tighten 10 cm Wheel3. 12 inch Wheel ORRemote Contact Assembly (RCA)(shown with optional 12 inch wheel) InpRemote Optical Sensor (ROS-P)Infrared Sensor (IRS-P)Magnetic Sensor with Amplifi er (MT-190P)Please visit for additional sensor TAKING Non-Contact Direct Contact Measurements6 Hand-heldLaser External Sensor (ROS shown)ORLightWARNING: Making measurements in direct contact with rotating equipment can be dangerous. Keep all loose clothing and hair away from exposed moving machinery. Keep the hand holding the instrument well behind the back end of the Remote Contact Assembly.

7 Properly replace all machinery guards after completing measurement. Do not use for rotation greater than 20,000 RCAfrom PLT200from PLT200 RotationalLinear(Use concave tip for small shafts)ONLY USE MODERATE TACH ometer ModeTachometer measures speed or linear rate with respect to time. Time intervals are sceonds, minutes, or hours. Rotational speed can be measured in Revolutions (Revs) per second, per minute, or per hour. The most common measurement is RPM or Revs per minute using the optical tachometer TACH ometer Setup1. Turn Power ON2. Enter Setup 3. Enter selection of Mode4. Select TACH Mode5. Save and advanceORRepeat until TACH displayedLast Mode selected is displayed1a. To toggle Lock On/OffLast Units selected are displayedLocked OnPress and Hold8 NONE, 1, 2 or 3 ORRepeat until desired decimal places displayedUnit will remember these settings (including lock on/off) even if turned off and back until desired Units displayedDONE, then Units selected6.

8 Enter selection of Units7. Select Units8. Save and advance9. Enter selection of number of decimal places10. Select decimal places11. Save and advance12. Exit Setup Ready to measureRPS, RPM or RATE ModeMeasurement of units in addition to Revs requires the attachment of the Remote Contact Assembly and tips/wheels. With this attachment, the unit can measure RATE inputs-revs, inches, feet, yards, centimeters and meters either per second, per minute or per hour, as well as miles per : External Remote Contact Assembly (RCA) must be inserted into input TACH ometer OperationMeasureRecall MaxRecall MinIf unit Locked on:Power OFFMin SpeedMax SpeedAutomatic after 90 seconds if unit not Locked onORPress and holdLock onResets Max/MinOR101. Turn Power ON2. Enter Setup 3. Enter selection of Mode4.

9 Select RATE Mode5. Save and advance6. Enter selection of UnitsORToggles between RATE and TOTAL. Select Mode selected is displayed1a. To toggle Lock On/OffRotational: C RPS, C RPM or C RPH EXTRN, then scrolling message, then last Units selectedLocked OnLinear: IPS, IPM, IPH, FT/S, FT/M, FT/H, YPS, YPM, YPH, MPH, CM/S, CM/M, CM/H, M/SEC, M/MIN, M/HPress and RATE Setup11 NONE, 1, 2 or 3 ORRepeat until desired decimal places displayedORRepeat until desired Units displayed8a. Enter selection of Wheel8b. Select Wheel8c. Save and AdvanceOnly for Linear Units:Rotational UnitsLinear UnitsORORT oggles between 10CM and 12 INLast Wheel selected is displayed7. Select Units8. Save and advance9. Enter selection of number of decimal places10. Select decimal places11. Save and advanceRATE Setup (continued) RATE OperationUnit will remember these settings (including lock on/off) even if turned off and back , USE CONTACT TIP or [wheel selected],then Units selectedMin SpeedMax SpeedORPress and holdLock on12.

10 Exit Setup Ready to measureMeasureRecall MaxRecall MinIf unit Locked on:Power OffResets Max/MinAutomatic after 90 seconds if unit not Locked TOTAL izer ModeTotalizer accumulates input on an ongoing basis. In the simplest form the unit acts as an optical counter, incrementing the display each time an input pulse is sensed. Using the Remote Contact Assembly with various tips and wheels, the unit can totalize in revs, inches, feet, yards, centimeters, and TOTAL izer Setup1. Turn Power ON2. Enter Setup 3. Enter selection of Mode4. Select TOTAL ModeORRepeat until TOTAL Mode selected is displayed1a. To toggle Lock On/OffDifferent messages displayed for Internal or External OnInternal optics or External optical sensor ( ROS):External Remote Contact Assembly:EXTRN, then scrolling message, then last Units selectedLast Units selectedPress and Hold145.