Transcription of KRONE LSA-PLUS Disconnection Module - TELEPART.NET
1 23 KRONE LSA-PLUS PROFIL Series 2 Disconnection ModulesApplicationKRONE LSA-PROFIL Series 2 is the modular systemfor cable connection and termination in telephone anddata communication networks. It is suitable for indoorand outdoor use in main distribution frames (MDF) data and PABX distribution (BDF/IDF) cross-connection cabinets (CCC) internal and external distribution point (DP). KRONE LSA-PROFIL Series 2 supports all commonvoice and data communication services such as analogue and digital (PCM30, ISDN) telephoneservices Ethernet, Token Ring video and audio signalsKRONE LSA-PROFIL Series 2 Disconnection Modules are typically used on the Subscriber or Network cablingside of distributors, where isolation of the line for testingpurposes might be and Functions Meets and exceeds Category 5 PerformanceSpecifications Compatible with ATM transmission speeds of155 Mbps Connection contacts provide permanent connectionbetween the cable and jumper side Center port provides additional contact point forparallel connection of test cords or installation ofovervoltage protection magazine Complete patching and cross-connect optionsprovide high versatility for easy changes and testing 8-Pair and 10-Pair sizesDimension 10-Pair Module NEW.
2 Brand-Marking for easy identificationKRONE Modules will always have the KRONE Logo onthe left side, and show the LSA-PLUS brand name onthe right side of the Module . Disconnection Contact Dimension 8-Pair Module23 Specifications & OrderingInformationGeneral Technical DataOperating temperature: -20 - +80 C / - 4 - +176 FMax. relative humidity: 93%, non-condensingMaterialsPlastic Parts:PBTF lammability:conforms to UL 94 V-0 Contact blade:special brass, msilver-platedin contact range: mMechanical DataIDC contact positioning:45 angle across wire axisSolid Wires: - AWG 26 - 21for connections with 2 wires - AWG 26 22 Stranded wires: 7 x AWG 28 20 Wire insulation diameter - mm (PVC & PE)No. of equal wire per contact slot max. 2No. of re-terminations: 200No.
3 Of patching cycles: 1000 Electrical DataInsulation resistance: 5 x 104 M Dielectric strength:2 kVRMSS urge voltage kV (wave sec)Surge current strength:10 kA (wave 8/20 sec)Contact resistance at IDC point:, typical value:1 m guaranteed value: m Contact resistanceincl. Disconnection contact: 10 m Transmission DataInsertion Loss @ 100 MHz: ( : required)Near-end Crosstalk @ 100 MHz: 42dB jumpered patched( : 40dB required)Standards ComplianceTransmission & Reliability:exceed ISO/IEC 11801 and TIA/EIA-568-APerformance in tropical climate: 40/92 DIN 50015 in corrosive environments: corrosive & salt laden air, DIN 40046 in vibrative environments:comply to BS 2011, part 2 Type ApprovalsTOT, CAT, TelecomAsia, OFTEL, DBP Telekom, PLDT,PERUMTEL, Telekom Malaysia and othersOrder Information:Description Part No. LSA-PROFIL Disconnection Module 2/10 6089 1 121-02 LSA-PROFIL Disconnection Module 2/86036 1 005-00 The KRONE Difference:The principle of the KRONE LSA-PLUS contact withthe 45 layout: Gas-tight, self cleaning contact Fast, simple installation Constant contact reliability for 15 years or more World-wide use in telecommunication and dataNetworksPerformance:Authorized Distributor.