Transcription of ARTIS The only hydrophobic IOL which is injected in a 1.8 ...
1 Made in FranceARTIS ARTIS INTRAOCULAR LENSThe only hydrophobic IOL which is injectedin a mm diameter cartridgeARTIS , two innovations are better than oneOphthalmologicsurgeryOphthalmologicsu rgeryCristalens12 all e Rosa Luxemburg - BP 50240 Eragny95615 Cergy Pontoise cedex - FranceT l : + 33 (0) 1 34 32 30 50 - Fax : + 33 (0) 1 34 32 30 60 Cristalens Industrie4 rue Louis de Broglie - 22300 Lannion - FranceT l : + 33 (0) 2 96 48 92 92 - Fax : + 33 (0) 2 96 48 97 DOC_4_PHOBIC4 reasons to prefer the new mat erial CristalensFaster unfolding, better controlOptimised refractive indexTransparent materialPositioning in the capsular bag easier to controlARTIS The only hydrophobic iol which is injected in a mm diameter cartridgeReflectance and index contrastThe gradient of the curve shows the unfolding time against practice, above 30 C in a cohesive OVD, com-plete unfolding (optical and haptic) is achieved in.
2 > 15 seconds for a hydrophilic iol > 22 seconds for the hydrophobic Cristalens > 62 seconds for a hydrophobic lens manufactured by the competitionDue to the presence of significant vacuoles in a lens, light diffusion increases as the angle of incidence of the light approaches the the pressure required for injection is low, the entire implant positioning process is simplified:> regular effortless sliding > controlled unfolding of the implant> positioning of the haptics at the required positions In a mm diameter cartridge, the injection pressure of our material is kg.
3 Other hydrophobic materials require a pressure of to kg. s In a mm cartridge, we are at kg, when no other hydrophobic material can be 000100010010070605040302010010 12 14 16 18 20 22 24 26 28 30 32 34 1,35 1,4 1,45 1,5 1,55 1,6 ARTIS Normalangle ofobservationLens transparent in waterLens with glisteningMaximumangle ofobservationLens 1 Lens 2 Lens 3 Lens 4 ARTIS reflection coefficientCoefficient of another referencehydrophobic materialLens indexRelative coefficientDeployment mm cartridge kg pressure33 23,5 14 To reduce both the iol optic thickness and the visual discomfort related to reflectance of the New designAnatomic conditions for precise, stable refractionARTIS.
4 Design better adapted to variationsin bag diameter A single iol diameter does not take into account the high variability in lens diameters : to mm. This diameter does not always vary with the axial length, the implant must therefore adapt to the bag diameter and not the opposite. This condition is required to guarantee the precision and stability of the refractive result. An implant which adapts to variations in capsular bag diameter will be better positioned in the ciliary diaphragm and on the optical axis.>> The implant adapts to the bagdiameter to ensure centration andcorrect position on the optical axis.
5 >> With better centration and notilting of the haptics or the experiment conducted in wells and on bank eyes (views in Miyake Apple,Liliana Werner laboratory, Salt Lake City) has demonstrated the ADAPTABILITYof the ARTIS design. In 9 to 10 mm wells, corresponding to the largest number of diameters encountered in clinics, the loops deform with no anterior or posterior angulation, keeping the same contact arc. An implant which adapts to the bag (and not the opposite) will be better centered in the bag and better positioned on the optical axis at the required position.
6 >> Diameter variation induced by the in Miyake Apple (Liliana Werner, Salt Lake City).+ mm+ mm2 mm mm mmDiameter of the empty lens bag mmARTIS mmOther mm1 The only hydrophobic iol which is injected in a mm diameter cartridgeARTIS TECHNICAL SPECIFICATIONSLens typeFor implantation in the capsular bagOptical mm ) mm * DOverall mm ) mm * DDesignOne piece with square edges on 360 OpticalAspherical on the posterior surface,partial compensation of corneal aberrations, biconvexAngulation5 MaterialHydrophobic Acrylic for micro-incisionDioptric powersFrom + D to + D- from + D to + D by + D - from + D to + D by + D - from + D to + D by + DEstimated ultrasound interference laser biometryRefractive oxideRecommended incision mm mmDESIGNATIONTECHNICAL SPECIFICATIONS