3 Port Solenoid Valve Series
Found 8 free book(s)Water Pressure Reducing Valves
media.wattswater.com• Valves can be installed in parallel or series configurations for extended ... • Common feature combinations include pressure reducing with hydrau-lic check, solenoid (on-off), downstream surge protection, or upstream ... • LF263A is a 3-way port model
Instruction Manual - Alfa Laval
www.alfalaval.comThe lower seat-push valve function connects to Out 3, which is keyed to the yellow/Lsp feedback. The air connection numbers are printed on the cover of the control unit. See the valve manual for information on the individual air ports on the valve. On the V70 with 5/2 solenoid valve, port Out 1 is normally closed (NC) and port Out 2 is normally
Swagelok Ball Valve Actuation Options
www.swagelok.comsee MAC® 900 series (standard solenoid) and MAC 200 series (explosion-proof solenoid) product literature . Actuation Pressure 25 to 150 psig (1 .7 to 10 .3 bar) 25 psig (1 .7 bar) is the minimum requirement for the solenoid valve . See valve product catalogs for minimum actuator pressure requirements . Temperature Range 0 to 120°F (–17 to ...
MONOBLOCK DIRECTIONAL CONTROL VALVE
www.walvoil.comH Fitted with a main pressure relief valve and a load check valve. H Available with parallel or series circuit. H Optional carry--over port (only for parallel circuit). H Diameter 20 mm --0.79 in interchangeable spools. H A wide variety of service ports and circuit valves.
High Flow NAMUR Valve G1/4 & G1/2
www.parker.comReduced inventory (3/2 & 5/2 functions with the same valve on 341Nx5 series) Mechanical part of the valve ATEX certifi ed according standard EN 13463-1 & -5 Function: 3/2 , 5/2, 3/2 <=> 5/2 and 5/3 valves. Manual override: Standard on all versions. Design: Solenoid operated spool valve with combined spring and air
Compact Resin Type/Male Thread AN05 to 40 Series RoHS
content2.smcetech.com5 to 60ºC Note 3) Note 1) It indicates the inlet pressure for solenoid valve. Note 2) The value may vary, depending on the pneumatic circuit or pressure that is exhausted from the solenoid valve. Note 3) The product can be used in temperatures –10 to 60°C if there is no risk of water droplets forming and freezing. Noise reduction 30 dB(A)
ELECTRO-PNEUMATIC
ultrabird.weebly.comdouble solenoid) Forward stroke: • When PB1 is pressed, coil Y1 is energised and 5/2 way DCV changes over. • Piston travels out and remains in the final forward position until a signal is applied to coil Y2. • The 5/2 DCV will remain in the last position because it is double solenoid valve and has no return spring.
Series II Skid Steer Loaders - pdf.germanbliss.com
pdf.germanbliss.com5 131522 plug sae12 3 3 6 131830 plate/floor short 1 1 7 131831 plate/floor long 5635 1 - 132002 plate/floor long 6635 - 1 8 131842 nut/spiralock™ 5/16 5 5 9 132050 strainer/fuel fill 1 1 650702 screw/machine phillips head #6 x 3/8 2 2 10 132051 cap/fuel fill 1 1 11 132298 washer/seal 4 4 12 134345 cover/toeplate 1 1 13 134756 sight port/oil ...