11 KV Substation. - bsiet.org

11 KV Substation. - bsiet.org

www.bsiet.org

The 11 kV line is connected to the transformer (11kV / 400 V) through gang isolator and fuses. 4. The lightning arresters are installed on the H.T. side to protect the sub-station from lightning strokes. 5. The transformer steps down the voltage to 400V, 3-phase, 4-wire supply. The voltage between any two lines is 400V whereas the voltage ...

NYY 1 x (1.5-800) mm² 0.6/1 kVNYY 1 x (1.5-800) mm² 0.6/1 kV

NYY 1 x (1.5-800) mm² 0.6/1 kVNYY 1 x (1.5-800) mm² 0.6/1 kV

www.kabel.co.id

NYY 4 x (1.5-400) mm² 0.6/1 kVNYY 4 x (1.5-400) mm² 0.6/1 kV Cu / PVC / PVC (Copper Conductor, PVC Insulated, PVC Sheathed) Standard Specification : IEC 60502-1 Electrical Data Nom. Cross Section Area Overall Diameter Cable Weight approx. mm² mm kg/km 1.5 13.8 259 2.5 15.0 324 4 17.3 453 6 18.7 563 10 21.5 794 16 23.5 1,083 25 27.5 1,558 35 ...

NX3008NBK 30 V, 400 mA N-channel Trench MOSFET

NX3008NBK 30 V, 400 mA N-channel Trench MOSFET

assets.nexperia.com

ESD protection up to 2 kV AEC-Q101 qualified 1.3 Applications Relay driver High-speed line driver Low-side loadswitch Switching circuits 1.4 Quick reference data Table 1. Quick reference data [1] Device mounted on an FR4 PCB, single-sided copper, tin-plated, mounting pad for drain 1 cm2. NX3008NBK 30 V, 400 mA N-channel Trench MOSFET

Cables de Media Tensión Media Tensión XLPE o EPR 5, 8, …

Cables de Media Tensión Media Tensión XLPE o EPR 5, 8, …

viakon.com

35 kV 90°C DESCRIPCIÓN GENERAL Cable monoconductor formado por conductor de cobre suave o aluminio duro 1350 , con pantalla ... 400 202,7 37 16,7 27,4 36,5 275 143 29,7 39,7 295 163 500 253,4 37 18,7 29,4 38,6 328 163 31,7 41,8 350 185 600 304,0 61 20,6 31,5 40,7 384 186 33,8 44,0 407 209

  Media, Cable, Xlpe, Tensi, Cables de media tensi, 243 n media tensi, 243 n xlpe

Raychem Heat-shrinkable Medium Voltage Terminations …

Raychem Heat-shrinkable Medium Voltage Terminations

www.cablejoints.co.uk

240 –400 IXSU-F 4141 OXSU-F 4141 27.7 – 35.6 400 –800 IXSU-F 4151 OXSU-F 4151 33.1 – 44.5 Termination for crimp lug Screened 3-core plastic and rubber cable without armour Cross section Tail Length Kit number Kit number [mm 2] [mm] Indoor Outdoor 25 –50 450 IXSU-F 4321 OXSU-F 4321 1200 IXSU-F 4324 OXSU-F 4324 70 –185 450 IXSU-F 4331 ...

  Medium, Heat, Voltage, Termination, Raychem, Shrinkable, Raychem heat shrinkable medium voltage terminations

Cables 0,6/1 kV RV-K 0,6/1 kV

Cables 0,6/1 kV RV-K 0,6/1 kV

www.cablesrct.com

Cables 0,6/1 kV RV-K 0,6/1 kV T. 976 500 120 T. 93 307 95 62 T. 91 691 85 48 T. 954 354 946 T. 96 375 90 70 Los datos contenidos en esta página, son meramente informativos, no constituyendo compromiso contractual de ningún tipo por parte de Cables RCT.

3-Phase Distribution Transformers 11 or 33 kV/415-240V ...

3-Phase Distribution Transformers 11 or 33 kV/415-240V ...

www.mstcecommerce.com

kV system in which the neutral is effectively earthed and they should be suitable for service with fluctuations in supply voltage upto plus 12.5% to minus 12.5%. (i) The transformers shall conform to the following specific parameters : Sl.No. Item 11 kV Distribution Transformers 33 kV Distribution Transformers 1 System voltage (Max.) 12 kV 36 kV

  Phases, Distribution, Transformers, 3 phase distribution transformers 11 or