SUBSTATION DESIGN CRITERIA DOCUMENT

SUBSTATION DESIGN CRITERIA DOCUMENT

www.eastpointenergycenter.com

Vertical Clearance of Unguarded Parts,2 Inches Horizontal Clearance of Unguarded Parts, Inches Vertical Break Disconnecting Switches,1 Inches Side Break Disconnecting Switches,1 Inches All Horn Gap Switches (Vertical and Side Break),1 Inches 72.5 350 125 59 60 72 84 34.5 200 114 48 36 48 60 1 ANSI C37.32 2 NESC, Section 12

  Design, Document, Criteria, Brake, Vertical, Vertical break, Substations, Substation design criteria document

High Voltage Disconnect Switches - GE Grid Solutions

High Voltage Disconnect Switches - GE Grid Solutions

www.gegridsolutions.com

GW7 Disconnect Switches. Double End Break Disconnect Switch. GW7 series disconnect switches are structured in three columns for single pole, double breaks, and horizontal rotary openings. There are three columns in each phase. Supporting insulators at both ends are fixed while the middle

  High, Switch, Voltage, Brake, Switches, Disconnect, High voltage disconnect switches, Break disconnect switch

Centrifugal Inline Fans - Greenheck-USA

Centrifugal Inline Fans - Greenheck-USA

content.greenheck.com

Disconnect Switch NEMA-1 disconnect switch is factory-mounted and wiring is provided from the motor as standard. All wiring and electrical components comply with the National Electric Codes and materials are UL Listed. Other NEMA enclosure disconnect switches are optional. Access Panels (not shown on images) The cabinet construction features two

  Switch, Disconnect, Disconnect switch

6300 Series Owner/Operator Manual

6300 Series Owner/Operator Manual

www.hayseed.net

A protective Thermal Breaker will “break” the 120 VAC power to POWER CONVERTER Section of Power Center if POWER CONVERTER becomes overheated— by operation above its maximum limit for an extended period of time or obstruction of ventilation to unit. POWER CONVERTER Section will instantly switch 12-volt light and motors to battery.

  Switch, Brake

POWER PRODUCT Panelboards - Siemens

POWER PRODUCT Panelboards - Siemens

assets.new.siemens.com

Accepts Vacu-Break Fusible Switch — — — — Accepts A Wide Range Of Circuit Breakers Optional Compression Lugs • Standard KO’s available on P1 and P2 – 5.75" Deep x 20" Wide boxes and P3 7.75" deep X 24" wide boxes. b For Next Gen P1, only when Subfeed Space is …

  Switch, Siemens, Brake

6300 Series Owner/Operator Manual - H a y s e e d

6300 Series Owner/Operator Manual - H a y s e e d

www.hayseed.net

A protective Thermal Breaker will “break” the 120 VAC power to POWER CONVERTER Section of Power Center if POWER CONVERTER becomes overheated— by operation above its maximum limit for an extended period of time or obstruction of ventilation to unit. POWER CONVERTER Section will instantly switch 12-volt light and motors to battery.

  Switch, Brake

Product Data WeatherMaster Single Packaged Rooftop

Product Data WeatherMaster Single Packaged Rooftop

www.shareddocs.com

Board by Carrier puts all connections and troubleshooting points in one con-venient place. Most low voltage con-nections are made to the same board and make it easy to access it. Setting up the fan is simple by an intuitive switch and rotary dial arrangement. Carrier rooftops have high and low pressure switches, a filter drier, and

  Switch

Product Data WeatherMaker Single Packaged Rooftop

Product Data WeatherMaker Single Packaged Rooftop

www.shareddocs.com

line-break overload protection •Units come with an easy access tool-less filter door. Filter track tilts out for filter removal and replace-ment. All filters are the same size in each unit Installation ease All WeatherMaker units are field-con-vertible to horizontal airflow, which makes it easy to adjust to unexpected job-site complications.

  Brake