Top 10+ Mistakes of DWV plumbing design - Lincoln …

Top 10+ Mistakes of DWV plumbing design - Lincoln …

www.co.lincoln.wa.us

back to back fittings (sinks) not directional {UPC 701.2.3} {UPC 704.1,704.2, 706.0} Sanitary tees may only be used on drainage piping when transitioning from horizontal (1/4” per foot) to vertical. All others must sweep in direction of flow with proper drainage fittings. 4. Trap arm too long for size of pipe {UPC1002.2}{UPC Table 10-1}

  Design, Fitting, Plumbing, Mistakes, Mistakes of dwv plumbing design

INTERNAL PLUMBING CODE PRESENTATION BASED ON …

INTERNAL PLUMBING CODE PRESENTATION BASED ON

www.maine.gov

Testing of plastic schedule 40 DWV • 105.3.4 Allowing the testing of plastic schedule 40 DWV piping systems with 5 psi maximum of air. For safety purposes, when testing with air, a listed 6psi relief valve is required. • Co-extruded ABS and PVC schedule 40 cellular core piping systems with referenced standards ASTM F1488 and ASTM F891 shall

  Based, Code, Internal, Presentation, Plumbing, Internal plumbing code presentation based on