Found 2 free book(s)Top 10+ Mistakes of DWV plumbing design - Lincoln …
www.co.lincoln.wa.usback to back fittings (sinks) not directional {UPC 701.2.3} {UPC 704.1,704.2, 706.0} Sanitary tees may only be used on drainage piping when transitioning from horizontal (1/4” per foot) to vertical. All others must sweep in direction of flow with proper drainage fittings. 4. Trap arm too long for size of pipe {UPC1002.2}{UPC Table 10-1}
INTERNAL PLUMBING CODE PRESENTATION BASED ON …
www.maine.govTesting of plastic schedule 40 DWV • 105.3.4 Allowing the testing of plastic schedule 40 DWV piping systems with 5 psi maximum of air. For safety purposes, when testing with air, a listed 6psi relief valve is required. • Co-extruded ABS and PVC schedule 40 cellular core piping systems with referenced standards ASTM F1488 and ASTM F891 shall