Found 9 free book(s)Department of Defense Sustainability Report ...
www.sustainability.govimplement energy efficiency strategies, in support of energy resilience, energy security and mission assurance. Energy efficiency is an important part of strengthening energy resilience and energy security. DoD guidance ensures alignment with requirements for facility evaluations as well as for energy efficiency performance standards and design
Optimized Chilled Water Plant Controls 2013-11-12-1
www.ashraeiowa.orgNov 12, 2013 · 4 Optimizing Energy Usage Chillers • Type, efficiency, size, VSD Cooling Towers • Fan type, efficiency, approach, range, speed control, flow turndown Chilled Water Pumps • Arrangement, flow rate (delta-T), pressure drop, VSD Condenser Water Pumps • Flow rate (delta-T), pressure drop Air Handling Units • Coil sizing, air-side pressure drop, water-side pressure
Model RTAC Air-Cooled Series R® Rotary Liquid ... - Trane
www.trane.comloads. At the same time chilled water temperatures will be maintained within +/- 1/2ºF [0.28°C] of setpoint. Reciprocating and screw chillers with stepped capacity control do well to maintain chilled water temperatures within 2ºF [1.1°C] of setpoint. Stepped control also results in overcooling your space because rarely does the capacity
Combined Heat and Power Technology Fact Sheet Series - …
www.energy.govficient of performance (COP), which is defined as useful thermal energy output (i.e., chiller load) divided by heat input. COP is a unit-less number and does not include energy consumed by pumps, fans, or other ancillary components. COP values for single stage chillers are less than one, and COP values for two
JOB DESCRIPTION TITLE: HVAC TECHNICIAN SUMMARY
i.slcc.eduutilizing steam and/or hot water for tempering or heating building, and a central chilled water ... • Must be able to set equipment trends to monitor energy consumption in Johnson ... better at their jobs and research professional development opportunities for your staff. • Assist Director in yearly performance evaluations of employees and ...
HVAC Systems: Overview
ceae.colorado.eduPart Load Performance 0 0.5 1 1.5 2 2.5 3 3.5 0 100 200 300 400 500 600 Energy Input Ratio, kW/Ton, Power per Capacity Efficiency degrades at part load Load, Tons Absorption Chillers Compressor replaced by pump Absorb refrigerant in other liquid Pump liquid to higher pressure Use heat to drive refrigerant from solution
ANSI/ASHRAE/IES Prepared by Pacific Standard 90.1-2016: …
www.oregon.gov• Exhaust Air Energy Recovery in 6.5.6.1 and tables 6.5.6.1-1 & 2 • Table 6.6.1 Power Usage Effectiveness (PUE) Maximum • Table 6.8.2 Minimum Duct Insulation R -Value • Table 6.8.3-1 Minimum Piping Insulation Thickness Heating and Hot Water Systems
New York State Energy Code
www.nyserda.ny.govA method for estimating the annual energy use of the proposed design and standard reference design based on estimates of energy use. Energy Code. The New York State Energy Conservation Construction Code (ECCCNYS) adopted pursuant to Article 11 of the New York State Energy Law. Exterior wall. Walls including both above-grade walls an d basement ...
BASIC HYDRONIC SYSTEM DESIGN - ctashrae.org
ctashrae.org8 NEW “SMART” PUMPS Speed varies without sensors High Efficiency ECM zElectronically Commutated Motor zA.k.a. DC Brushless Motor Integral VFD Sophisticated Electronics Residential to Light Commercial TYPE GPM HD (FT.) HP RPM HORIZ. IN-LINE 20 - 375 10 - 75 ¼ - 3 1760, 3500 END SUCTION 40 – 4,000 10 - 400 ⅓- 200 1160, 1760, 3500 VERTICAL IN …