Found 7 free book(s)TECHNICAL DESIGN CATALOG - Metal Stud Framing
www.steeler.comNon-Load Bearing Walls: NL1 Non-Load Bearing Wall Framing NL2 Sill and Head Track Connection Detail NL3 Corner Framing Detail NL4 Slammer Stud Detail NL5 Window Opening Framing Detail NL6 Door Opening Framing Detail NL7 Non-Load Bearing Opening NL8 Non-Load Bearing Wall Parallel to Joist Roofs (Rafters/Joists): R1 Roof Framing
6. INSTALLATION
bca.gov.sg• Do not splice vertical metal stud members. • To check overall verticality of studs. 6. Install bracing • Horizontal bracing for all stud partitions to be as per manufacturer’s recommendation. • Provide all braced framing of load bearing steel stud framing as detailed in approved shop drawings. Additional hollow section for bracing
Advanced Wall Framing - Energy Star
www.energystar.gov• Using two-stud corner framing and inex-pensive drywall clips or scrap lumber for drywall backing instead of studs. • Eliminating headers in non-load-bearing walls. • Using in-line framing in which floor, wall, and roof framing members are vertically in line with one another and loads are transferred directly downward.
H-Stud Area Separation Wall System - American Gypsum
www.americangypsum.comWhen wall framing is spaced greater than 1" away from the ASW, aluminum clips with longer legs are permitted. Contact clip manufacturer for customized clips. While the ASW system is non-load bearing, the adjoining framed walls can be designed as load bearing walls. The walls adjacent to the ASW system can be erected of wood or steel framing.
System Design Considerations - USG
www.usg.com5. Axial load on the stud. 6. Shear stress of the stud. 8. Allowable deflection of the stud. 9. Web crippling of stud at supports. 10. Lateral bracing. Stud Selection Selection of a stud gauge and size must take into account a num ber of factors. The key consideration is whether the assembly is for a load-bearing, nonload-bearing or curtain ...
Construction Type Guidelines - ICW Group
icwgroup.comThe walls consist of load-bearing frame components (typically cross sections) and multi-story load-bearing panels. Curtain wall systems are characterized by pre-cast concrete panels, metal, glass or stone panels. The structural system of a pre-cast building consists of pre-cast columns and beams. Precast Concrete (other than Title-up) (ATC 14)
Light Steel Framing Design Standards
lpe.ku.edu• D001-13, Durability of CFS Framing Members • D100-13, Corrosion Protection of Fasteners • D200-12, Corrosion Protection for CFS Framing in Coastal Areas • F100-09, Design of Clip Angle Bearing Stiffeners • F101-12, Screws for Attachment of SteelTo- -Wood and Wood-Steel • F102-11, Screw Fastener Selection • F140-10, Welding CFS