Maintenance and testing of portable fire
Found 9 free book(s)PORTABLE FIRE EXTINGUISHERS - New York City
www.nyc.govbut a portable fire extinguisher servicing company (certified by the FDNY) must come in at least once a year and perform any maintenance, recharging, and/or testing that is …
NFPA 10
www.nfpa.orgPortable Fire Extinguishers 2013 Edition Reference: 7.1.2.1, 7.1.2.2, 7.3.1, 7.3.2 F.I. No.: 10-98-1 Background: Some people claim that a maintenance procedure that does not require internal maintenance is essentially the same as a monthly inspection procedure, so only minimal knowledge is required and no special training.
IX. DRILLING PHASE: DRILLING, CASING AND COMPLETION ...
www.dec.ny.govportable tanks for handling combustible liquids, use of cleaning materials that have a flash point greater than 100eF, and locating fuel storage tanks some distance, such as 50' to 75', from a wellbore. Routine inspections, testing and maintenance of rig components also help avoid accidents from drilling operations. Daily inspections should include
NFPA 72 Fire Alarm Inspection and Testing Requirements 1.6 ...
recimi.org14 Fire Safety Consultants, Inc. 27 Fire Alarm System - Testing 14.4 – Testing • 14.4.1.2 – Reacceptance Testing • Changes to site-specific software require: 100% test of all functions known to be affected by the change Additionally, 10% of initiating devices that are not directly affected by the change (up to 50 devices) shall be tested to verify correct system operation
PORTABLE FIRE EXTINGUISHER INSPECTION AND …
www.pbfd.netPORTABLE FIRE EXTINGUISHER INSPECTION AND MAINTENANCE SCHEDULE NFPA 10, 4-3.1 Frequency. Fire extinguishers shall be inspected when initially placed in service and thereafter at approximately 30-day intervals. Fire extinguishers shall be inspected at more frequent intervals when circumstances require. NFPA 10, 4-3.2: Procedures.
Annex - 1 Fire-fighting Systems and Appliances Summary …
www.irclass.orgAll fire hoses are hydrostatically tested All Annually Ship Marine Notice FIR -001 Rev.06/12 B The fire extinguishers should be examined and, if necessary, serviced annually. The annual servicing/ examination of the portable fire extinguishers can be carried out by the crew, if the crew is properly trained and such servicing is acceptable
Fire Safety Log Book
www.essex-fire.gov.ukAll testing of equipment should be in accordance with the manufacturer’s instructions. Portable Fire Extinguishers. website *Further information on British Standards can be found by visiting the British Standards . And the current British Standard 7. Further guidance can be found in Part 2 of the appropriate DCLG guides under the above heading.:
Fire Safety Log Book - Leicestershire Fire and Rescue Service
leics-fire.gov.ukFire Alarm (BS5839)/Emergency Lighting System (BS5266:1) The fire alarm and emergency escape lighting system are required to be monitored and tested by a nominated competent persons. These persons should have sufficient information and training in order to carry out all aspects of routine testing and supervision of the system.
FIRE DEPARTMENT CITY OF NEW YORK
www.nyc.govout-of-service fire protection system. A fire guard should be available to patrol all areas in which the fire protection system is out of service at least once every hour. No individual fire guard should patrol more than 50,000 square feet of building floor area. If coverage area is over 50,000 sq ft. more than 1 fire guard should be assigned.