Room Cooling Units With Modulating Capacity
Found 8 free book(s)NEW REQUIREMENTS IN THE 2019 CALIFORNIA TITLE 24 …
dialecticeng.comModulating Cooling Capacity for HVAC Systems Direct-expansion (DX) HVAC equipment is still required to have the capability to stage or modulate cooling capacity. DX units with a capacity greater than 65,000 Btu/h (5.4 tons) that control the capacity of the unit based on space temperature, must have minimum of two (2) stages of cooling.
Airside Economizers and ASHRAE Standard 90.1-2013 - Trane
www.trane.comtwo stages of mechanical cooling capacity. This capacity threshold will drop from 75,000 Btu/hr to 65,000 Btu/hr (5.4 tons, 19 kW) on January 1, 2016. All other DX units, including those that control space temperature by modulating airflow, need to comply with the following requirements (listed in Table 6.5.1.4):
ANSI/ASHRAE/IES Prepared by Pacific Standard 90.1-2016: …
www.oregon.gov• Small individual fan units: < Table 6.5.1-1 • Chilled-water cooling systems without a fan or that use induced airflow with certain capacity in certain climate zones • Systems with nonparticulateair treatment per Standard 62.1 • Hospitals where >75% of the air must be humidified >35°Fdp
Product Data WeatherMaster Gas Heat/Electric Cooling ...
www.shareddocs.comSingle-stage units deliver SEERs up to 15.6, EERs up to 13.0, and IEERs up to 13.0. Two-stage units deliver EERs up to 12.2, units with single speed in-door motors deliver IEERs up to 14.0, and units with 2-speed indoor fan mo-tor deliver IEERs up to 16.0. All mod-els are capable of either vertical or hor-izontal to meet nearly every light com-
38CKC 50 Hz Product Data - Carrier
carrier.com.kwreliable summer cooling performance. Built into these units are the features most desired by customers today, including EER ratings of up to 10.0 when used with components designated by manufacturer. FEATURES/BENEFITS Electrical Range — Single phase units are available in 018, 024, and 036 sizes in 220-240v. Three-phase units are available
YORK Duct-Free Mini-Split Systems - Johnson Controls
www.johnsoncontrols.comoutdoor units provide extremely high part-load efficiency. They are an excellent choice for energy-conscious customers. • Are highly flexible. A selection . of heating and cooling or cooling-only system options are available to meet the application’s exact capacity and SEER requirements. • Provide quiet, customized comfort.
Commercial Self-Contained - Trane
www.trane.com• Increased capacity to meet today’s growing floor plates and building loads • Compact cabinet to minimize mechanical room requirements • Up to 17% more efficient than competitive units • Low leaving air temp capability to reduce fan motor energy, improve accoustical performance, and minimize duct sizes
HVAC Variable Refrigerant Flow Systems
www.seedengr.comthe speed to follow the variations in the total cooling/heating load as determined by the suction gas pressure measured on the condensing unit. The capacity control range can be as low as 6% to 100%. Refrigerant piping runs of more than 200 ft are possible, and outdoor units are available in sizes up to 240,000 Btuh.