Wall Air Conditioners
Found 7 free book(s)COLEMAN®-MACH® AIR CONDITIONERS - RV Comfort
old.rvcomfort.comwall mounted thermostat), with contacts that control the 115 VAC used to power the roof top unit. A low voltage controller controls all air conditioning functions. The low voltage controller controls a 12 VDC electrical circuit, which is used to energize the relays in the ceiling plenum. The low voltage controller that RV Products
commodity codes
web.uri.edu031-05 Air Conditioners (cooling and Cooling/heating Types): Window and Wall Mounted, and Parts and Accessories Not Individually Itemized 031-06 Air Conditioning and Heating: Central Units, and Parts and Accessories Not Individually Itemized 031-07 Air Circulation Equipment (not Otherwise Classified) 031-08 Air Curtains 031-09 Air Flow Meters
Multi-Split Type Air Conditioners
www.daikin.com.au1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.
Modular Multi-position Air Handlers
www.trane.com1 These Air Handlers are A.H.R.I. certifiedwith various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data. 2 3/4" Male Plastic Pipe (Ref.: ASTM 1785-76) PRODUCT SPECIFICATIONS MODELGAM5B0C48M41SB GAM5B0C48M41EA RATED VOLTS/PH/HZ. …
Energy Recovery Ventilators - Greenheck-USA
content.greenheck.comExhaust Air Outdoor Air 95°F 125 grains/lb. Supply Air 80°F 87 grains/lb. Return Air 75°F 50% RH Summer Operation Exhaust Air Outdoor Air-13°F 1 grains/lb. Supply Air 49°F 27 grains/lb. Return Air 72°F 35% RH Winter Operation The total energy wheel is constructed of a polymer heat transfer media for sensible energy transfer and a silica
UNIFIED FACILITIES CRITERIA (UFC) DoD MINIMUM ...
wbdg.orgEngineering Command (NAVFAC), and Air Force Civil Engineer Center (AFCEC) are responsible for administration of the UFC system. Defense agencies should contact the preparing service for document interpretation and improvements. Technical content of UFC is the responsibility of the cognizant DoD working group. Recommended changes with supporting
Installer’s Guide Condensing Units - Trane Heating & Air ...
www.trane.comair conditioning product may result in personal injury and/or property damage. The manufacture or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connec-tion with its use. These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only