Found 2 free book(s)GUIDELINES FOR PUMP SYSTEM DESIGNERS Jacques …
www.pumpfundamentals.comthe pump this will help you diagnose pump system problems. It is also useful to have a pressure gauge on the suction side, the difference in pressure is proportional to the total head. The pressure gauge reading will have to be corrected for elevation since the reference plane for total head calculation is the suction flange of the pump. 4.
PUMP PERFORMANCE MEASUREMENTS Jacques …
www.pumpfundamentals.comJacques Chaurette p. eng. www.lightmypump.com April 2003 Synopsis This article examines how to take flow and pressure measurement and then calculate the total head of a pump based on these measurements. How to do motor power measurements and where to get the data required on the motor such as efficiency and