Example: marketing
Search results with tag "Performance of lvds with different cables"
Performance of LVDS with different cables - TI.com
www.ti.com30 Analog and Mixed-Signal Products August 2000 Analog Applications Journal Performance of LVDS with different cables Introduction to LVDS Low-voltage differential signaling (LVDS) runs fast—very
Performance of LVDS with Different Cables (Rev. B)
www.ti.comSLLA053B 6 Performance of LVDS With Different Cables •The line impedance must be 100 Ω ±15% for the bandwidth of 1 MHz up to the maximum frequency applied. •The propagation delay time on the line should not exceed 5.7 ns/m (at 10 MHz).The skew (difference between two lines of a pair) is not specified, even though it has a significant