Transcription of 25 mm CENTRIFUGAL FANS - silavent.co.uk
1 25 CURZON - 100mm CENTRIFUGAL fans . DIMENSIONS. C Measured in mm A E. D A : 216. B : 195. C : 50. B. D : 52. E : 98. * : 80/100. *. * (80mm without adaptor . 100mm with adaptor). PERFORMANCE GRAPH TECHNICAL DATA. For MAINS VOLTAGE MODELS. CURZON CENTRIFUGAL . CURZON - 100mm CENTRIFUGAL fans . Pa Extract Volume : 80 m3/h 140 Sound Volume *. : (A)@3m Voltage : 230-240v AC~. 120 Frequency : 50 Hz 100 Wattage : 35W. Max. Temp. : 50 C. 80 Weight : kg 60 Max Pressure : 150 pa 40 Double Insulated 20 *. : Independent Tests 14-7-2003. 0. 0 20 40 60 70 80 90 m3/h SELV MODELS. PERFORMANCE GRAPH TECHNICAL DATA. For SELV MODELS. CURZON CENTRIFUGAL SELV. Transformer Pa Input Voltage : 230-240v AC~. 140 Output Voltage : 12v AC~. 120 Fan Input Voltage : 12v AC~. 100. Extract Volume : 72 m3/h 80. Sound Volume : (A)@3m 60 Frequency : 50 Hz 40 Wattage : 44W. Max. Temp. : 50 C. 20. Weight : kg (Combined).
2 0 Max Pressure : 125 pa 0 20 40 60 70 m3/h The SELV models of the Curzon CENTRIFUGAL range are designed for use within the bath / shower areas and are fitted with long life 12v AC~ motors. The low voltage supply is from a transformer which is supplied with each SELV model ordered. The SELV models are available with over-run timer or humidistat & timer. Transformers should be located outside the splash zone but all fans are suitable for siting within this area. The Curzon fan can be sited up to 8 metres from the transformer CURZON - 100mm CENTRIFUGAL fans 26. PRODUCT SUMMARY. High Performance Levels 80m3/h (22 l/s). BEAB Approved IP24 Rated Humidity Versions Now Fitted With Intelligent Humidistat Control Boards Integral Back Draught Shutters Mains Voltage and SELV Models Available Surface Mount or In-Line Models Available CURZON - 100mm CENTRIFUGAL fans . 3 Year Replacement Warranty on All Models MODELS AVAILABLE.
3 Code Model CUR 7001B Standard CUR 7002B Pull - cord CUR 7003B Over - run Timer CUR 7004B Humidistat & Timer CUR 7005B Timer & PIR Intelligent . Humidity Controls Fitted CUR 7006B Humidistat, Timer & PIR to Humidistat Models CUR 9003LV SELV Single Speed - Over-run Timer CUR 9004LV SELV Single Speed Humidistat & Timer CUR 501A Fire Shutter Back Plate (1 Hour Rated). CUR 7001 BKIT In Line Version - Standard CUR 7003 BKIT In Line Version - Timer SPECIFICATION & INSTALLATION OVERVIEW. The silavent Curzon range of fans are ideal for bathrooms and toilets where longer duct runs are required. Made from high gloss ABS, these fans produce an impressive pressure performance required to extract air along longer ducting runs and are capable of extracting up to 80m3/h. Easy to install, the Curzon fans are built to the highest quality with the motor mounted on rubber bushes for quietness and long life.
4 This range of fans is designed for wall or ceiling fixing and for use with all silavent 100mm duct and flatduct. It can also be used in conjunction with an integral fire shutter back plate which is rated to 1 hour (FLA501A). The pull cord model is not suitable for ceiling mounting. The humidistat versions are now fitted with the new Intelligent electronic humidity controls which work as intelligent humidistat. Unlike traditional humidity controls which trigger when humidity reaches a pre-set level, the Intelligent board reacts to a significant rate of change in a location's humidity level - See Mayfair Range for full explanation of how Intelligent controls operate. The in-line versions of the CURZON are designed to provide a powerful CENTRIFUGAL fan to fit out of sight within the roof area. Giving the same performance as the surface mounted version, this model is ideal for use with the silavent SPOTVENT.
5 Shower light products. 27 MAYFAIR - SERIES 70 CENTRIFUGAL fans . DIMENSIONS. D E. Measured in mm . A : 250. C : 115. A. D : 40. E : 80. C. F : 115. : 85 (FAN). A. TECHNICAL DATA. PERFORMANCE GRAPH. For MAINS VOLTAGE MODELS. MAYFAIR SERIES 70 CENTRIFUGAL . MAYFAIR - SERIES 70 CENTRIFUGAL fans . Extract Volume : 70 m3/h (HIGH). Pa : 43m3/h (LOW). Sound Volume *. : 105 : 90 Voltage : 230-240v AC~. Frequency : 50 Hz 75 Wattage : 35W (HIGH). 60 : 20W (LOW). Max. Temp. : 50 C. 45 Weight : kg (FAN ONLY). Max Pressure : 105 pa 30. 15 Double Insulated *. : Independent Tests 14-7-2003. 0. 0 10 20 30 40 50 60 70 m3/h For Single Sped Models, Use Higher Extract Figures FAN OPERATION. SINGLE SPEED. Standard : Single Speed Fan operated by separate light switch / remote switch (not supplied). Pull Cord : Single Speed Fan is operated by integral pull cord Timer : Single Speed Fan operated by separate light switch / remote switch (not supplied).
6 The integral adjustable timer allows the fan to continue operating up to 25 minutes after being switched off Humidistat : Single Speed Fan. Manual and Automatic operation. The Intelligent Humidity Control (IHC). works on detection of a significant change in the rate of increase in humidity levels. Whilst traditional humidistat controls wait for the humidity to reach a pre-set level, IHC detects a significant increase in a location's humidity level and activates the extract fan immediately. Once the humidity is reduced, the integral adjustable timer allows the fan to continue operating for between 2 minutes and 25 minutes. This fan is operated by separate light switch / remote switch (not supplied). Infra Red : The fan is activated by movement within the detection area of up to 5 metres. When movement is no longer detected, the integral adjustable timer allows the fan to continue operating for between 2 minutes and 25 minutes TWIN SPEED.
7 Standard : Twin Speed Fan designed to operate continuously at low speed. High speed is activated by separate light switch / remote switch (not supplied). Timer : As the standard model but incorporates an integral adjustable timer. The timer will operate for between 2 minutes to 25 minutes after the switch has been turned off and the fan will return to running at the low speed. This fan is operated by separate light switch / remote switch (not supplied). Humidistat : Single Speed Fan. Manual and Automatic operation. The Intelligent Humidity Control (IHC). works on detection of a significant change in the rate of increase in humidity levels. Whilst traditional humidistat controls wait for the humidity to reach a pre-set level, IHC detects a significant increase in a location's humidity level and activates the extract fan immediately. Once the humidity is reduced, the integral adjustable timer allows the fan to continue operating for between 2 minutes and 25 minutes.
8 This fan is operated by separate light switch / remote switch (not supplied). MAYFAIR - SERIES 70 CENTRIFUGAL fans 28. PRODUCT SUMMARY. Recessed or Surface Fixing on Wall / Ceiling (In-Line Option Also Available). Integral Back Draught Shutters (SINGLE SPEED fans ONLY). BEAB Approved Extract Rate 70m3/h (20 l/s) (HIGH SPEED). 43m3/h (12 l/s) (LOW SPEED). IPX4 Rated Plug In Fan Design - Ideal For Large Building Projects MAYFAIR - SERIES 70 CENTRIFUGAL fans . Intelligent Humidistat Technology 3 Year On-Site Warranty on All Models MODELS AVAILABLE. Code Model MSS 070B Single Speed - Standard MTD 070B Single Speed - Over - run Timer MPC 070B Single Speed - Pull Cord Intelligent . Humidity Controls Fitted MCC 070B Single Speed - Humidistat & Pull Cord to MIR 070B Single Speed - Timer & PIR Humidistat Models MTS 070B Twin Speed - Continuous Trickle With Boost MTT 070B Twin Speed - Continuous Trickle With Boost & Timer MCT 070B Twin Speed - Humidistat, Timer & Pull Cord SPECIFICATION & INSTALLATION OVERVIEW.
9 The Mayfair Series 70 is designed to be installed in 2 parts the building in frame first to reduce initial installation costs and on-site damage, followed by a plug-in fan body which allows easy maintenance and replacement. This is a system used effectively over the past 40 years by silavent and proves to be highly effective on large building projects. The unit is constructed of high gloss ABS with a motor mounted on rubber bushes to provide high pressure performance combined with an impressive quietness. RECESSED USE CEILING USE. MOUNTING . FITTING MAY 905B FLA 105A. (With 225mm x 25mm Flatduct). SURFACE USE CEILING USE. MOUNTING MOUNTING . (REMOVE FAN MOTOR DOME COVER). MAY 504A PFL 420A. (With 110mm x 54mm Flatduct). IN-LINE USE WASHABLE USE. MOUNTING FILTER COVER . (NOT PIR, HUMIDISTAT MODELS). MAY 908B MAY 901A. (NOT PIR, HUMIDISTAT MODELS). 29 MAYFAIR - SERIES 100 CENTRIFUGAL fans .
10 DIMENSIONS. D E. Measured in mm . A : 250. C : 115. A D : 40. E : 80. C. F : 115. : 85 (FAN). A. TECHNICAL DATA. PERFORMANCE GRAPH. For MAINS VOLTAGE MODELS. MAYFAIR SERIES 100 CENTRIFUGAL . MAYFAIR - SERIES 100 CENTRIFUGAL fans . Extract Volume : 97 m3/h (HIGH). Pa : 50m3/h (LOW). 140 Sound Volume *. : : 120 Voltage : 230-240v AC~. 100 Frequency : 50 Hz Wattage : 50W (HIGH). 80 : 20W (LOW). 60 Max. Temp. : 50 C. Weight : kg (FAN ONLY). 40 Max Pressure : 150 pa 20 Double Insulated 0 *. : Independent Tests 14-7-2003. 3. 0 20 40 60 70 80 90 100 m /h For Single Speed Models, Use Higher Extract Figures FAN OPERATION. SINGLE SPEED. Standard : Single Speed Fan operated by separate light switch / remote switch (not supplied). Pull Cord : Single Speed Fan is operated by integral pull cord Timer : Single Speed Fan operated by separate light switch / remote switch (not supplied). The integral adjustable timer allows the fan to continue operating up to 25 minutes after being switched off Humidistat : Single Speed Fan.