0,6/1kV CABLES LKM-HF Unarmoured power and control …

40,6/1kV CABLESDESIGN: STANDARDS:IEC 60092-353, design1. Conductor- stranded copper conductor IEC 60228, class 22. Insulation- XLPE plastic IEC 60092-3513. Bedding- separator tape4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on requestLKM-HFUnarmoured power and control cable0,6/1kVApplication:For fixed installation in most areas and on open deck in characteristicsRated voltage0,6/1kV (1,2kV)Maximum conductortemperature+ 90 CFlame-retardantIEC 60332-1-2-test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and CABLES , category AHalogen-freeIEC 60754 seriesSmoke emissionIEC 61034 seriesMinimum recommended installation temperature -15 CLowest operation temperature -40 CCore identification: see technical information sectionIdentification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheathFlame-retardantFire-resistantHalog en-freeLowsmokeemission11/2008 Tel.

5 0,6/1kV CABLES G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 LKM-HF 0,6/1kV Part number Number of conductors &

Tags:

  Cable, 6 1kv cables, Hf 0, 6 1kv

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 0,6/1kV CABLES LKM-HF Unarmoured power and control …

1 40,6/1kV CABLESDESIGN: STANDARDS:IEC 60092-353, design1. Conductor- stranded copper conductor IEC 60228, class 22. Insulation- XLPE plastic IEC 60092-3513. Bedding- separator tape4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on requestLKM-HFUnarmoured power and control cable0,6/1kVApplication:For fixed installation in most areas and on open deck in characteristicsRated voltage0,6/1kV (1,2kV)Maximum conductortemperature+ 90 CFlame-retardantIEC 60332-1-2-test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and CABLES , category AHalogen-freeIEC 60754 seriesSmoke emissionIEC 61034 seriesMinimum recommended installation temperature -15 CLowest operation temperature -40 CCore identification: see technical information sectionIdentification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheathFlame-retardantFire-resistantHalog en-freeLowsmokeemission11/2008 Tel.

2 +358 2 410 8700, fax +358 2 410 8750, ,6/1kV CABLESG-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 LKM-HF 0,6/1kVPart numberNumber ofconductors &cross-sectionn x mm2 NominalouterdiametermmApproximateweight kg/kmCurrentrating AMin. bendingradius fixedinstallationmmNormal G-type25 642 1x66,595523025 644 1x107,5140723025 646 1x168,5205963525 648 1x2511,53201275025 650 1x3512,04201575025 652 1x5014,05551966025 654 1x7017,07902427025 656 1x9518,010402937525 658 1x12020,013003398025 660 1x15023,516103899525 662 1x18526,0200544416025 664 1x24029,0261552217525 666 1x30032,0323560119525 670 2x1,58,080203525 686 2x2,510,0115264025 702 2x411,0155344525 701 2x611,5205445025 717 2x1014,5315616025 711 2x1616,5465827025 713 2x2520,57001088525 715 2x3523,59901339525 67125 6723x1,58,5100163525 68825 6893x2,510,5145214525 70325 7043x411,0200284525 70525 7063x612,5280365025 70725 7083x1015,5425506525 70925 7103x1618,0630677525 71225 8513x2521,5960899025 71425 8523x3525,0133511015025 71625 8533x5028,5178513717525 71825 8543x7033,5257016920525 72025 8553x9537,5338020522525 72225 8563x12042,0425523725525 72425 8573x15048,0523527229025 67325 6744x1,59.

3 5135164025 69025 6914x2,511,5180215025 72525 7264x413,0260285525 72725 7284x614,5355366025 72925 7304x1017,0545507025 73125 6994x1620,0820678025 73225 7004x2524,012658910025 73325 7194x3527,0172511016525 73425 7214x5032,0232513719525 73525 7234x7038,0332516923025 98425 9854x9543,0442520526025 879 4x12047,5551523728525 67625 6775x1,510,5160144525 69225 6935x2,512,5220185025 86425 8655x414,0315256025 86625 8675x615,0445306025 86825 8695x1018,0675447525 87025 8715x1621,01015568525 678 7x1,512,0200125025 694 7x2,513,0285165525 667 10x1,514,5290116025 993 10x2,516,5415147025 680 12x1,516,0335106525 696 12x2,517,0470137025 991 14x1,516,0375106525 995 14x2,519,0545138025 989 16x1,517,542597025 997 16x2,520,0615128025 682 19x1,518,049097525 873 19x2,521,0700118525 875 24x1,521,563589025 877 24x2,525,09251015025 684 27x1,522,569089025 675 37x1,524,5910710011/200860,6/1kV CABLES11/2008 DESIGN: STANDARDS:IEC 60092-353, design1.

4 Conductor- stranded copper conductor IEC 60228, class 52. Insulation- XLPE plastic IEC 60092-3513. Bedding- separator tape4. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on requestLKM-HF FLEXU narmoured power cablewith flexible conductor0,6/1kVTel. +358 2 410 8700, fax +358 2 410 8750, :For fixed installation in most areas and on open deck in !This cable is not designed for movable or portable conductor CABLES ease the installation in areas involvingtight bending radius or high characteristicsRated voltage0,6/1kV (1,2kV)Maximum conductortemperature+ 90 CFlame-retardantIEC 60332-1-2-test for single insulated wire and cableIEC 60332-3-22 -test for bunched wires and CABLES , category AHalogen-freeIEC 60754 seriesSmoke emissionIEC 61034 seriesFor details see general information sectionMinimum recommended installation temperature -15 CLowest operation temperature -40 CCore identification: see technical information sectionIdentification.

5 Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheathFlame-retardantFire-resistantHalog en-freeLowsmokeemission70,6/1kV CABLES11/2008G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5 LKM-HF FLEX 0,6/1kVPart numberNumber ofconductors &cross-sectionn x mm2 NominalouterdiametermmApproximateweight kg/kmCurrentrating AMin. bendingradius fixedinstallationmmNormal G-type25 647 1x169,0185944025 649 1x2512,02901235025 651 1x3513,03851535525 653 1x5016,05351966525 655 1x7017,57452407025 657 1x9520,09652848025 659 1x12022,512153319025 661 1x15025,5153038115525 663 1x18529,0186542917525 665 1x24033,0247550720026 047 1x30035,5303058221526 054 2x1617,0405807026 055 2x2522,56151059026 056 2x3524,584013010026 07126 0723x1619,0555668026 07326 0743x2524,08558610026 07526 0763x3526,0117010716026 07726 0783x5031,0165013719026 07926 0803x7036,0230016822026 08126 0823x9543,0301019926026 08326 0853x12047,5381523228526 08426 0863x15054,0476026732526 10126 1024x1620,0725668026 10326 1044x2526,511258616026 10526 1064x3529,5153010718026 10726 1084x5035,0217013721026 10926 1104x7040,5301016824526 11126 1124x9547,0399019928526 11326 1144x12052,5499523231526 13126 1325x1622,5900559026 13326 1345x2528,5142571175 DESIGN.

6 STANDARDS:IEC 60092-353, design1. Conductor- stranded copper conductor IEC 60228, class 22. Insulation- XLPE plasticIEC 60092-3513. Bedding- filler tape4. Armour- copper wire braid, coverage > 90%IEC 60092-3505. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request80,6/1kV CABLES11/2008 LKSM-HFArmoured power and control cable0,6/1kVTel. +358 2 410 8700, fax +358 2 410 8750, :For fixed installation in most areas and on open deck in characteristicsRated voltage0,6/1kV (1,2kV)Maximum conductortemperature+ 90 CFlame-retardantIEC 60332-1-2-test for single insulated wire and cableIEC 60332-3-22-test for bunched wires and CABLES , category AHalogen-freeIEC 60754 seriesSmoke emissionIEC 61034 seriesMinimum recommended installation temperature -15 CLowest operation temperature -40 CCore identification: see technical information sectionIdentification.

7 Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheathFlame-retardantFire-resistantHalog en-freeLowsmokeemission25 742 1x63,17,5130524525 744 1x103,59,0185725525 746 1x164,110,0255966025 748 1x254,913,03801278025 750 1x355,514,04951578525 752 1x508,716,066519610025 754 1x709,918,591524211525 756 1x9511,820,5118029312525 758 1x12012,322,5145533913525 760 1x15013,725,0177538915025 762 1x18515,127,5218044416525 764 1x24017,031,0281552219025 766 1x30018,733,5346560120525 770 2x1,53,810,0130206025 785 2x2,54,311,0160267025 801 2x44,912,0205347525 803 2x65,413,5260448525 805 2x108,716,04006110025 807 2x1610,018,05558211025 809 2x2512,322,583510813525 811 2x3514,025,5107513315525 77225 7733x1,54,110,5155166525 78625 7873x2,54,611,5195217025 80225 8803x45,213,0260288025 80425 8823x65,813,5335368525 80625 8843x109,317,05155010525 80825 8863x1610,719,57356712025 81025 8883x2513,224,011108914525 81225 8903x3515,126,5145011016025 81425 8923x5017,531,0191513719025 81625 8943x7020,136,0267016922025 81825 8963x9522,740,0347520524025 82025 8973x12035,044,5442523727025 82225 8983x15039,150,0541027230025 77425 7754x1,54,511,5185167025 78825 7894x2,55,012,0245217525 83025 8314x45,814,0315288525 83225 8334x68,816,04453610025 83425 8354x1010,318,56505011525 83625 8374x1611,921,09456713025 83825 8394x2514,726,514158916025 84025 8414x3516,729,5186011018025 84225 8434x5019,434,0246013720525 84425 8454x7022,439,5345516924026 00526 0064x9535,044,5464520527026 00726 0084x12039,149,5575023730025 77625 7775x1,55,012,0220147525 79025 7915x2,55,613,0285188026 01126 0125x48,615,0410259026 01326 0145x69,716,55353010026 01526 0165x1011,819,57954412026 01726 0185x1613,223,511505614525 778 7x1,55,412,5265127525 792 7x2,511,414,5405169026 025 10x1,59,616.

8 03951110026 033 10x2,511,718,05401411025 780 12x1,59,917,04401010525 794 12x2,511,819,55951312026 027 14x1,510,517,54951010526 035 14x2,511,920,06801312026 030 16x1,511,818,5550911526 037 16x2,512,521,07601213025 782 19x1,511,820,0610912025 796 19x2,513,222,08551113525 828 24x1,513,923,5790814525 798 24x2,515,726,011001016025 783 27x1,514,123,5845814525 784 37x1,516,026,510857160 LKSM- hf 0 ,6/1kVPart numberNumber ofconductors &cross-sectionn x mm2 NominalouterdiametermmApproximateweight kg/kmCurrentrating AMin. bendingradius fixedinstallationmmNormal G-typeCross-section ofscreenmm290,6/1kV CABLES11/2008G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5100,6/1kV CABLES11/2008 LKSM-HF FLEXA rmoured power cablewith flexible conductor0,6/1kVTel. +358 2 410 8700, fax +358 2 410 8750, :For fixed installation in most areas and on open deck in !This cable is not designed for movable or portable conductor CABLES ease the installation in areas involvingtight bending radius or high characteristicsRated voltage0,6/1kV (1,2kV)Maximum conductortemperature+ 90 CFlame-retardantIEC 60332-1-2-test for single insulated wire and cableIEC 60332-3-22-test for bunched wires and CABLES , category AHalogen-freeIEC 60754 seriesSmoke emissionIEC 61034 seriesFor details see general information sectionMinimum recommended installation temperature -15 CLowest operation temperature -40 CCore identification: see technical information sectionIdentification: Lot number, cable type, cable size, voltage, temperature,standards, production month, manufacturer's name andmeter marking printed on the sheathFlame-retardantFire-resistantHalog en-freeLowsmokeemissionDESIGN: STANDARDS:IEC 60092-353, design1.

9 Conductor- stranded copper conductor IEC 60228, class 52. Insulation- XLPE plasticIEC 60092-3513. Bedding- filler tape4. Armour- copper wire braid, coverage > 90%IEC 60092-3505. Sheath- polyolefine plastic, SHF1 IEC 60092-359- standard colour black, other colours on request110,6/1kV CABLES11/2008 LKSM-HF FLEX 0,6/1kVPart numberNumber ofconductors &cross-sectionn x mm2 NominalouterdiametermmApproximateweight kg/kmCurrentrating AMin. bendingradius fixedinstallationmmNormal G-type26 237 1x164,110,0240946026 238 1x254,913,53601238526 239 1x355,514,54601539026 240 1x508,716,565019610026 241 1x709,918,587024011526 242 1x9511,821,0111528413026 243-1x12012,324,0138533114526 244 1x15013,727,0171538116526 245 1x18515,129,5206542918026 246 1x24017,033,0270550720026 247 1x30018,735,0330058221026 254 2x1610,017,55208010526 255 2x2512,322,578010513526 256 2x3514,025,0101013015026 27126 2723x1610,719,56806612026 27326 2743x2513,224,010308614526 27526 2763x3515,126,5135010716026 27726 2783x5017,532,5187513519526 27926 2803x7020,136,0254516822026 28126 2823x9522,741,5329519925026 28326 2843x12035,047,5422523228526 28526 2863x15039,153,5525026732526 30126 3024x1611,921,58756613026 30326 3044x2514,726,513158616026 30526 3064x3516,730,0173010718026 30726 3084x5019,435,0241013721026 30926 3104x7022,440,5329016824526 31126 3124x9535,047.

10 5440519928526 31326 3144x12039,152,5549023231526 33126 3325x1613,223,5106555145 Cross-section ofscreenmm2G-type is with yellow/green earth conductor and marking on sheath is, for example, 3G1,5120,6/1kV CABLES11/2008 LKSM-EMCTel. +358 2 410 8700, fax +358 2 410 8750, :For fixed installation in most areas and on open deck in to meet requirements for improved EMC screening characteristicsRated voltage0,6/1kV (1,2kV)Maximum conductortemperature+ 90 CFlame-retardantIEC 60332-1-2-test for single insulated wire and cableIEC 60332-3-22-test for bunched wires and CABLES , category AHalogen-freeIEC 60754 seriesSmoke emissionIEC 61034 seriesTransfer impedanceIEC 61196-1(typical value 26dB over 1m /mat 100 MHz [20m /m])For details see general information sectionMinimum recommended installation temperature -15 CLowest operation temperature -40 CCore identification: See technical information with yellow/green protective earth (PE)conductor on requestIdentification.