Operating 15 manual04_GBACP 3000 electronic D 51709 Marienheide-Rodt Tel. 02264/17-0 Fax 02264/17126 Parameter Code SummaryPARA-METERDESCRIPTIONFACTORYSETTI NGRANGEPAGECUSTOMERSETTING02-RVLVLS oftware Revision3503-IRATI nverter Rated CurrentA3507-FLT3 Last Fault3608-FLT2 Second Fault3609-FLT1 First Fault3612-FOUTM otor Output Hz3613-VOUTM otor Output Voltage0 100%of line voltage3614-IOUTM otor Output A3615-LOADI nverter Load0 200%of 03-IRAT3617-TEMPI nverter C361A-FSTATS tator-Frequency(1) Hz55 Read-only21-MODEI nput Mode3(2) 0 1136/5524-FSELS peed Setpoint Selector0(2) 0 1938/5531-FMINM inimum Hz3832-FMAXM aximum Hz3833-F2 Preset Frequency Hz3834-F3 Preset Frequency Hz3835-F4 Preset Frequency Hz3836-F5 Preset Frequency Hz3837-F6 Preset Frequency Hz3838-F7 Preset Frequency Hz3839-FTLM inimum Frequency in Torque Hz3941-RSELRamp Selector0(2) 0 739/5642-ACC1 Acceleration Time s3943-DEC1 Deceleration Time s3944-ACC2 Acceleration Time s4045-DEC2 Deceleration Time s4046-DECTLD eceleration Time in Torque s4047-DCBRKDC Brake s4048-DCVLTDC Brake Voltage2/3 of 52-BOOST0 15%4051-VSELV/Hz Characteristic Selector00 54052-BOOSTV oltage K

21.12.98 Operating manual 04_GB ACP 3000 — 0.37–15.0 1 Berges electronic • D–51709 Marienheide-Rodt • Tel. 02264/17-0 • Fax 02264/17126

Tags:

  04 gb

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 04 gb - gongkong

1 Operating 15 manual04_GBACP 3000 electronic D 51709 Marienheide-Rodt Tel. 02264/17-0 Fax 02264/17126 Parameter Code SummaryPARA-METERDESCRIPTIONFACTORYSETTI NGRANGEPAGECUSTOMERSETTING02-RVLVLS oftware Revision3503-IRATI nverter Rated CurrentA3507-FLT3 Last Fault3608-FLT2 Second Fault3609-FLT1 First Fault3612-FOUTM otor Output Hz3613-VOUTM otor Output Voltage0 100%of line voltage3614-IOUTM otor Output A3615-LOADI nverter Load0 200%of 03-IRAT3617-TEMPI nverter C361A-FSTATS tator-Frequency(1) Hz55 Read-only21-MODEI nput Mode3(2) 0 1136/5524-FSELS peed Setpoint Selector0(2) 0 1938/5531-FMINM inimum Hz3832-FMAXM aximum Hz3833-F2 Preset Frequency Hz3834-F3 Preset Frequency Hz3835-F4 Preset Frequency Hz3836-F5 Preset Frequency Hz3837-F6 Preset Frequency Hz3838-F7 Preset Frequency Hz3839-FTLM inimum Frequency in Torque Hz3941-RSELRamp Selector0(2)

2 0 739/5642-ACC1 Acceleration Time s3943-DEC1 Deceleration Time s3944-ACC2 Acceleration Time s4045-DEC2 Deceleration Time s4046-DECTLD eceleration Time in Torque s4047-DCBRKDC Brake s4048-DCVLTDC Brake Voltage2/3 of 52-BOOST0 15%4051-VSELV/Hz Characteristic Selector00 54052-BOOSTV oltage Knee Hz4254-SKBNDSkip Frequency Hysteresis Hz4255-SK1 Skip Frequency Hz4256-SK2 Skip Frequency Hz4257-SK3 Skip Frequency Hz4259-MVOLTR ated Motor Voltage230/400 V185 240 V;370 480 V425B-MSATM otor Saturation Level47%15 80%4261-LTLFLoad Torque Limit Forward150%10 150%42 Berges electronic D 51709 Marienheide-Rodt Tel. 02264/17-0 Fax 02264/17126 Operating 3000 :Level 1 Parameters shown shaded.(1)Additional parameters that are only available when using the PI controller and whenthe 81-PRGNO parameter is set to a value between 80 and 95 (see page 56).

3 Seechapter 6, from page 51 on, for further information about the PI controller.(2)Extended parameters when using the PI controller. For further information about thePI controller, see chapter 6, as from page Torque Limit Reverse150%10 150%4263-RTLFR egenerative Torque Limit Forward80%10 110%4264-RTLRR egenerative Torque Limit Reverse80%10 110%4265-SLIPSlip (2) Stability Adjustment30 44367-TOLT imed Overload Trip Point0%0 100%4368-NRSTTrip Restart Number00 84469-DRSTR estart Delay s446A-TOLCT imed Overload Characteristic00 74570-MCALA nalog Meter Output Calibration MET1 Set for10 VDC0 2554571-METERA nalog Meter Output Selector MET11(2) 0 545/5672-ST1 Open Collector Output 170 104675-STRA uxiliary Relay Output10 104677-MOLM otor Overload Input20 3 4778-MCAL2 Analog Meter Output Calibration MET20 20 mA or 4 20 mA;set for 20 mA0 2554779-MET2 Analog Meter Output Selector MET23(2) 0 1547/5681-PRGNOS pecial Program/PI Control Characteristics00 999948/5682-STARTS tart Options10 114883-PWMPWM Carrier Frequency Selector10 54984-DISPD isplay Option Setting00 30004987-ACODES ecurity Access Code00 9995097-RVLVL2 Software Revision Level Correction(1) Hz55A6-ERROR2 Final Error(1) 55 Read-onlyA7-ERROR1 Initial Error(1) 55 Read-onlyA8-SIPARTI ntegral Sum(1) 55 Read-onlyB3-KPProportional Gain(1) 0 25555B4-KIIntegral Gain(1) 0 25555B5-KINVIN1 Scaling(1) 0 manual04_GBACP 3000 electronic D 51709 Marienheide-Rodt Tel.

4 02264/17-0 Fax 02264/17126 Table of ContentsPage1 General Information .. of Symbols and Notes .. and Operating Instructions for Drive Converters.. 52 Technical Data .. Identification Number .. Specifications .. Drive Specifications .. Data (Size I) .. Data (Size II) .. Data (Size III) .. Data (Size IV) .. 103 Installation.. Rules for Installation.. (Electromagnetic Compatibility) .. on how to solve the Problem of Radio Frequency InterferenceSuppression of Frequency Converters to VDE 0875/EN 55011 .. Filters/Output Chokes .. Specifications .. Suppression Measures .. Ordinance (EMC Directive, 89/336 EEC) .. Practices .. Codes .. Wiring .. Wiring/Interface .. Power Connection .. Conditions .. Protection .. Mains Filters.. Starting .. Connection.. Current Surges and Voltage Transients.

5 And Use of Terminals .. Access Cover Removal.. Assignment (Mains supply 1 230 VAC, kW) .. Assignment (Mains supply 3 400 VAC, kW) .. Assignment (Mains supply 3 400 VAC, kW) .. Keypad/Program Memory Unit Connector (J22) .. Terminal Description .. Configuration .. 29 Berges electronic D 51709 Marienheide-Rodt Tel. 02264/17-0 Fax 02264/17126 Operating 3000 Started .. Information .. Keypad .. Operation .. Mode (RUN and STOP Modes).. Mode .. Indicator .. of Displays.. Tips .. Start .. 345 Parameter Configuration and Description .. Descriptions .. 356PI Controller .. of PI Control .. and Feedback Inputs .. PI Controller Values.. for PI Control.. 547 Connection Diagrams.. Line and Motor Connections (Mains supply 1 230 VAC and 3 400 VAC) . Run/Stop Connections.

6 Run/Stop Connections .. Relay Output and Digital Output ST1 .. Terminal Connections .. Speed Input Connections (VIN1/VIN2) .. Connections .. 618 Troubleshooting .. Indications .. Trip Indications .. a Fault .. Codes .. 639 Appendix .. Code Summary.. Added or Amended when PI Control is Utilized .. manual04_GBACP 3000 electronic D 51709 Marienheide-Rodt Tel. 02264/17-0 Fax 02264/171261 General of Symbols and NotesWork Safety SymbolYou will find this symbol next to all work safety notes in this operating manual if there is arisk of injury or death for persons involved. Pay attention to these notes and observe par-ticular caution in such cases. Also pass on all work safety instructions to other WarningThis symbol is shown wherever particular caution is necessary owing to occurring or ap-plied voltages ( DC voltages up to 650 V) and where special precautionary measureshave to be taken.

7 The inverter must always be isolated from the mains when working on NoteThis note is shown in all parts of this operating manual to which particular attention must bepaid to ensure that the guidelines, specifications, notes and the correct sequence of workwill be obeyed and to prevent damage or destruction of the inverter and/or and Operating Instructions for Drive Converters1. GeneralIn operation, drive converters, depending on their degree of protection, may have live,unisolated, and possibly also moving or rotating parts, as well as hot case of inadmissible removal of the required covers, of improper use, wrong installationor maloperation, there is the danger of serious personal injury and damage to further information, see operations serving transport, installation and commissioning as well as maintenance areto be carried out by skilled technical personnel (Observe IEC 364 or CENELEC HD 384or DIN VDE 0100 and IEC 664 or DIN/VDE 0110 and national accident prevention rules!)

8 For the purposes of these basic safety instructions, skilled technical personnel means per-sons who are familiar with the installation, mounting, commissioning and operation of theproduct and have the qualifications needed for the performance of their draw attention to the fact that no liability can be assumed for damage and malfunctionsresulting from failure to observe the operating amendments of illustrations and data given in this operating manual are reservedin the interest of improving the unit and its Intended UseThe application of the drive converter described in this operating manual exclusively servesthe purpose of continuously variable speed control of three-phase converters are components designed for inclusion in electrical installations or drive converters are designed for installation in a switchgear cabinet and for operator of the system is solely liable for damage resulting from improper use of thedrive !

9 Berges electronic D 51709 Marienheide-Rodt Tel. 02264/17-0 Fax 02264/17126 Operating 3000 items expressly approved by BERGES ( mains filter, choke, external braking chop-pers and braking resistors etc.) may be used as installer of the system is liable for any damage resulting from the use of accessoriesthat have not been approved expressly by BERGES. Please consult us in case of case of installation in machinery, commissioning of the drive converters ( the startingof normal operation) is prohibited until the machinery has been proved to conform to theprovisions of the directive 89/392/EEC (Machinery Safety Directive MSD). Account is tobe taken of EN ( the starting of normal operation) is admissible only where conformitywith the EMC directive (89/336/EEC) has been drive converters meet the requirements of the low-voltage directive 73/23/EEC.

10 Theyare subject to the harmonized standards of the series prEN 50178/DIN VDE 0160 in con-junction with EN 60439-1/DIN VDE 0660, part 500, and EN 60146/DIN VDE technical data as well as information concerning the supply conditions shall be takenfrom the rating plate and from the documentation and shall be strictly Transport, StorageThe instructions for transport, storage and proper use shall be complied established after delivery must be notified to the transport company necessary, the supplier must also be notified before the damaged drive converter isput into climatic conditions shall be in conformity with prEN InstallationThe installation and cooling of the appliances shall be in accordance with the specificationsin the pertinent drive converters shall be protected against excessive strains. In particular, no compo-nents must be bent or isolating distances altered in the course of transportation or contact shall be made with electronic components and converters contain electrostatic sensitive components which are liable to damagethrough improper use.