1. Chemical product and company identification

MSDS Number2010/11/30 Creation DateFUJI DRI-CHEM DILUENT DL(CRP)DC100402G1 1 1 1 / / / / 4444 material safety data SHEET1. Chemical product and company identificationProduct nameFUJI DRI-CHEM DILUENT DL(CRP) product usageFUJI DRI-CHEM: Dilution for CRP SamplePoison Help Emergency Call : Oosaka 072-727-2499(24hrs) Tsukuba029-852-9999( )Japan Poison Information Center (In case of accidantal poioning call either)03-6418-935003-6418-2199 Medical Systems Business , Nishiazabu, Minato-ku, Tokyo, 106-8620 FUJIFILM CorporationTelephone NumberEmergency ContactsFAX NumberTelephone NumberDivisionAddressCompany NameReference numberDC100402G2. Hazards identificationGHS-classificationNot classifiedAcute toxicity (Oral)Health hazardsNot classifiedSkin corrosion/irritationNot classifiedSerious eye damage/eye irritation *Degree of Hazards: Smaller category number is more hazards resulting from the material as hazardsThis product has been found to be non-reactive for HBs Ag(hepatitis-B virus antigen),anti-HCV(hepatitis-C virus) and anti-HIV(human immuno deficiency virus) antibodies.

MSDS Number DC100402G Creation Date FUJI DRI-CHEM DILUENT DL(CRP)2010/11/30 11 1 / 1 // / 4444 MATERIAL SAFETY DATA SHEET 1. Chemical product and company identification

Tags:

  Product, Company, Identification, Data, Chemical product and company identification, Chemical, Safety, Material, Material safety data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1. Chemical product and company identification

1 MSDS Number2010/11/30 Creation DateFUJI DRI-CHEM DILUENT DL(CRP)DC100402G1 1 1 1 / / / / 4444 material safety data SHEET1. Chemical product and company identificationProduct nameFUJI DRI-CHEM DILUENT DL(CRP) product usageFUJI DRI-CHEM: Dilution for CRP SamplePoison Help Emergency Call : Oosaka 072-727-2499(24hrs) Tsukuba029-852-9999( )Japan Poison Information Center (In case of accidantal poioning call either)03-6418-935003-6418-2199 Medical Systems Business , Nishiazabu, Minato-ku, Tokyo, 106-8620 FUJIFILM CorporationTelephone NumberEmergency ContactsFAX NumberTelephone NumberDivisionAddressCompany NameReference numberDC100402G2. Hazards identificationGHS-classificationNot classifiedAcute toxicity (Oral)Health hazardsNot classifiedSkin corrosion/irritationNot classifiedSerious eye damage/eye irritation *Degree of Hazards: Smaller category number is more hazards resulting from the material as hazardsThis product has been found to be non-reactive for HBs Ag(hepatitis-B virus antigen),anti-HCV(hepatitis-C virus) and anti-HIV(human immuno deficiency virus) antibodies.

2 However,there is no absolute proof of informationSee Section 15. REGULATORY INFORMATION3. Composition/information on ingredientsSubstance or MixtureMixtureCAS #ISHL (%)ENCS notificationComponents80 - 100water------7732-18-57 - 15casein from milk9000-71-90 - azide1-482(1)-48226628-22-8 Chemical formulaH2O (7732-18-5), NaN3 (26628-22-8)(*) Generally Chemical substances greater than 1% of the total are : The notes / remarks within the brackets [ ] following the Chemical substance names are used to communicate the followingindications: "PRTR S1" : Chemical substances that are designated in the Law for Promoting the Management of Chemical Substances asSpecific Class 1 Chemical Substances. "PRTR 1" : Chemical substances that are designated as Class 1 Chemical substances in the same Law. "PRTR 2" : Chemical substances that are designated as Class 2 Chemical substances in the same Law. "SSN" : Chemical substances that are subject to notification in accordance with the Labor safety and Health First aid measuresIn case of inhalationRemove victim to fresh air and keep at rest in a position comfortable for breathing.

3 Call a POISONCENTER or contactRinse skin with water/shower. Get medical attention if irritation develops and contactRinse with water. Get medical attention if irritation develops and mouth thoroughly. Get medical attention if any discomfort of first-aidrespondersRescuers should wear proper personal protective equipment suitable for Corporation MSDS JapanF0003LS01 MSDS Number2010/11/30 Creation DateFUJI DRI-CHEM DILUENT DL(CRP)DC100402G2 2 2 2 / / / / 44445. Fire-fighting measuresExtinguishing mediaCarbon dioxide, dry Chemical and protein based media to fire fightingproceduresKeep personnel removed from and upwind of fire. Water runoff can damage the environment. Dike and collect water used to fight fire Evacuate area and fight fire from a safe of fire-fightersWear adequate personal protective Accidental release measuresPersonal precautions,protective equipment andemergency measuresWear adequate personal protective equipment, see Section 8 (Exposure Controls/PersonalProtection)Environmenta l precautionsPrevent from entering into soil, waterways and ground methods andmaterials and containmentmeasuresSpills should be contained by, and covered with suitable absorbent material and removed Handling and storageHandlingTechnical measuresAvoid contact with skin, eyes and clothing.

4 Wash hands after and generalventilationUse only with adequate care in handling adviceDo not get in eyes and avoid contact with skin and clothing. Wash hands thoroughly storageconditionsProtect from sunlight. Keep container tightly packaging materialsUse plastic container that have enough Exposure controls/personal protectionOccupational exposure limitsComponentsTypeValuesodium azide (26628-22-8) mg/m3 TWA Engineering measuresEvacuate and ventilate spill area. Provide easy access to water supply and eye wash protective equipmentRespiratory protectionWear suitable respiratory protectionWear suitable protectionUse eye protection. Use face shield in case of splash and body protectionWear suitable protective measuresHandle in accordance with good industrial hygiene and safety Physical and Chemical propertiesAppearanceClear liquidFormTransparent colourlessColorPractically data point/Freezing pointNo data point, initial boilingpoint, and boiling rangeNo data pointNo data temperatureNo data limit - lower (%)FUJIFILM Corporation MSDS JapanF0003LS01 MSDS Number2010/11/30 Creation DateFUJI DRI-CHEM DILUENT DL(CRP)DC100402G3 3 3 3 / / / / 4444No data limit - upper (%)No data pressureNo data densityNo data gravityNo data (water)No data coefficient(n-octanol/water)No data temperature10.

5 Stability and reactivityStabilityStable at normal of hazardousreactionsMixing with a acid or a heavy metal may form highly explosive metal to avoidFreezing. Protect against direct materialsAcids. Heavy decompositionproductsCO,CO2 Other InformationMay be released the harmful hydrogen azide when mixing with Toxicological informationTest ResultsAcute Oral LD50 Rat: > 2000 mg/kgSkin corrosion/irritationNo irritationSerious eye damage/eyeirritationnon irritant12. Ecological informationBioaccumulationNot in soilNot hazardous effectsNot established13. Disposal considerationsWhen your own wastewater treatment plant is not available, collect entire waste and then charge to a licensed industrial wastemanagement professional with manifests for industrial waste. Laws and regulations to be followed while disposing of this product orwaste : Japanese Waste Control and Public Cleaning Law: Falls under the category of an industrial waste (acidic waste) JapaneseWater Pollution Control Law:Living environment-related item Japanese Sewer Management Law : Restricts discharging Transport informationMarine transportation is regulated by IMDG Code.

6 Air transportation is regulated by IATA Dangerous Goods Information for marine and air transportation to be passed to the shipping company ---------------IMDGNot regulated as dangerous regulated as dangerous Regulatory informationLaw concerning the Examination and Regulation of Manufacture etc. of Chemical SubstancesClass 1 Specified Chemical Substance:Not 2 Specified Chemical Substance:Not 1 Monitoring Chemical Substance:Not 2 Monitoring Chemical Substance:Not 3 Monitoring Chemical Substance:sodium azideIndustrial safety and Health LawDangerous Substances Flammable:Not Substances Flammable Gases:Not Corporation MSDS JapanF0003LS01 MSDS Number2010/11/30 Creation DateFUJI DRI-CHEM DILUENT DL(CRP)DC100402G4 4 4 4 / / / / 4444 Dangerous Substances Oxidizing:Not Substances Explosives:Not Substances Ignitable:Not Substances Carcinogen:Not 1 Designated Chemical Substances:Not 2 Designated Chemical Substances:Not 3 Designated Chemical Substances:Not 1 Organic Solvents Preparations:Not 2 Organic Solvents Preparations:Not 3 Organic Solvents Preparations:Not Substance:Not Requirements:Not :Not and Deleterious Substances Control LawSpecified Poisonous Substance - Main Law.

7 Not Poisonous Substance - Cabinet Order:Not Substances - Main Law:Not Substances - Cabinet Order:Not Substances - Main Law:Not Substances - Cabinet Order:Not Order Article 32-2:Not Order Article 32-3:Not Considered Poisonous:Not Considered Deleterious:Not Order, Preparations:Fire Service LawClass 1 Oxidizing Solids:Not 2 Flammable Solids:Not 3 Spontaneous combustibility andWater-reactivity Substances:Not 4 Flammable Liquids:Not 5 Self-Reactive Substances:Not 6 Oxidizing Liquids:Not Flammable Substances:Not Reporting Substance:Not PRTRS pecific Class 1 Designated Substance:Not 1 Designated Substance:Not 2 Designated Substance:Not safety LawNot Aeronautics lawNot Marine PollutionPrevention LawNot Pressure Gas safety lawNot Powder Control LawNot Other informationThis information is provided without warranty. The information is believed to be correct. This information should be used to make anindependent determination of the methods to safeguard workers and the environment.

8 This MSDS is prepared according to the MSDS guideline of Japan Chemical Industry Association based on JIS Z7250:2005. FUJIFILM Corporation MSDS JapanF0003LS01