And company identificationTrade NameVectra The following SDS applies to products described by combinations of the following trade name, Product gradeand color code listed Grade(s):A130, A515, A530, A540, A625, A910RX, A920RX, A950, A9500, A950RX, AFINES, B230, B950, B950RX, CEL950RX,C950RX, E530I, E540I, E543I, E820I, E820 IPD, E9500, E9500I, E950 IPP, E950 IRX, E950 ISX, E950PP, E950RX,E950SX, EIFINES, H950RX, J540, J543, J9500, J950PP, J950SX, K540, K950RX, L950RX, MT 1300, MT 1340,MT 1345, MT 4350, RD1000, RD1000H, RD1025H, RD3000H, RD3000L, RD4001, RD501, S540, S625, S950PP,S950SX, S950SX HIGH MV, , , T820, T840, T950PP, T950SX, V100P, V300P, V400P, VX-29PP,VX-29 SXColor Code:See Section 16 for list of Color CodesManufacturer, importer, supplierTicona Polymer, business of Celanese8040 Dixie , KY 41042 United emergency phone numbers:In USA, call 800 424 9300 Outside USA, call 703 527 3887, collect calls crystal polymer / LCPI dentified usesPlastic processing Hazard IdentificationAccording to Regulation 2012 OSHA Hazard Communication Standard; 29 CFR Part :This material is not hazardous under the criteria of the Federal OSHA Hazard Communication S

1. Product and company identification Trade Name Vectra® The following SDS applies to products described by combinations of the following trade name, product grade

Tags:

  Product, Company, Identification, Product and company identification

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1. Product and company identification Vectra® - …

1 And company identificationTrade NameVectra The following SDS applies to products described by combinations of the following trade name, Product gradeand color code listed Grade(s):A130, A515, A530, A540, A625, A910RX, A920RX, A950, A9500, A950RX, AFINES, B230, B950, B950RX, CEL950RX,C950RX, E530I, E540I, E543I, E820I, E820 IPD, E9500, E9500I, E950 IPP, E950 IRX, E950 ISX, E950PP, E950RX,E950SX, EIFINES, H950RX, J540, J543, J9500, J950PP, J950SX, K540, K950RX, L950RX, MT 1300, MT 1340,MT 1345, MT 4350, RD1000, RD1000H, RD1025H, RD3000H, RD3000L, RD4001, RD501, S540, S625, S950PP,S950SX, S950SX HIGH MV, , , T820, T840, T950PP, T950SX, V100P, V300P, V400P, VX-29PP,VX-29 SXColor Code:See Section 16 for list of Color CodesManufacturer, importer, supplierTicona Polymer, business of Celanese8040 Dixie , KY 41042 United emergency phone numbers:In USA, call 800 424 9300 Outside USA, call 703 527 3887, collect calls crystal polymer / LCPI dentified usesPlastic processing Hazard IdentificationAccording to Regulation 2012 OSHA Hazard Communication Standard; 29 CFR Part :This material is not hazardous under the criteria of the Federal OSHA Hazard Communication Standard ( )3.

2 Composition/information on ingredients1 of 8 Vectra Issuing Data SheetMSDS number87101000 Revision nameRevision Number0_____3. Composition/information on ingredientsChemical characterizationLiquid crystal polymer / LCP, unreinforcedRemarksThis Product may contain proprietary is a polymeric material. Any hazardous constituents are wetted by the polymer system, and therefore are unlikely topresent exposure under normal conditions of processing and First aid measuresSkinCool skin rapidly with cold water after contact with molten polymer. Do not peel solidified Product off the skin. Immediatemedical attention is flush eye(s) with plenty of water. Call a physician if irritation to fresh air in case of accidental inhalation of vapors. Get medical attention immediately if symptoms swallowed, do not induce vomiting - seek medical to physicianThis Product is essentially inert and nontoxic.

3 However, if it is heated at too high a temperature or if it is burned, gasesmay be released. Patients who have been exposed to off-gases may need to have their arterial blood gases andcarboxyhemoglobin levels checked. If the carboxyhemoglobin levels are normal, asphyxia (carbon dioxide replacingoxygen) is a possibility. As with any fire, irritant gases may have formed. If patients may have inhaled high concentrationsof irritating fumes, they should be monitored for delayed onset pulmonary Fire-fighting measuresSuitable extinguishing mediaWater, Foam, Dry powderExtinguishing media which must not be used for safety reasonsDo not use a solid water stream as it may scatter and spread exposure hazards arising from the substance or preparation itself, its combustion products, or releasedgasesUnder conditions giving incomplete combustion, hazardous gases produced may consist ofCarbon monoxideCarbon dioxide (CO2)Nitrogen oxides (NOx)Special protective equipment for fire-fightersWear self-contained breathing apparatus and protective of 8 NFPA:NAGH/ENHealth: 1 Flammability: 0 Instability.

4 0 Safety Data SheetMSDS number87101000 Revision nameRevision Number0 Vectra Issuing precautionsDike and collect water used to fight InformationKeep people away from and upwind of fire. Dust can form an explosive mixture in Accidental release measuresPersonal precautionsDo not breathe dust. Avoid dust formation. For personal protection see section precautionsShould not be released into the for cleaning upUse mechanical handling equipment. Dispose of in accordance with local Handling and storageAdvice on safe handlingDo not handle hot or molten material without appropriate protective equipment. Do not exceed recommended processtemperatures to minimize release of decomposition products. Maintain good housekeeping in work Provideappropriate exhaust ventilation at machinery and at places where dust can be - fire and explosion:Do not smoke in areas where polymer dust is Appropriate measures should be taken to control the generationand accumulation of dust during conveying and processing storageKeep in a dry, cool and well-ventilated place.

5 Maintain dryness of productsstrong bases8. Exposure controls / personal protectionOSHA Exposure LimitsNo exposure limits Exposure LimitsNo exposure limits National Exposure LimitsNo exposure limits established3 of 8 Product nameRevision Number0 Vectra Issuing Data SheetMSDS number87101000 Revision controlsEngineering measuresGeneral: May not be adequate as the sole means to control employee Exhaust: Recommended when appropriate to control employee exposure to dust or process equipmentA safety shower and eyebath should be readily adviceDo not breathe dust. Do not handle hot or molten material without appropriate protective protectionIn case of insufficient ventilation wear suitable respiratory equipmentSkin protection:When thermal or melt processing, wear long pants, long sleeves, well insulated gloves, and face shield when there is achance of protection:Safety goggles.

6 Safety glasses with :Operations involving grinding and machining of parts should be reviewed to assure that particulate levels are kept belowrecommended standards9. Physical and chemical propertiesAppearanceFormpelletsOdorsligh t specificMolecular Weight> (base resin)Combustible applicableIgnition temperature> 540 C (1004 F)MethodASTM D 1929 Water solubilityinsoluble10. Stability and reactivityChemical stabilityStable under normal conditionsConditions to avoidFlame. Contact with strong alkali solutions may soften the material. Avoid prolonged heating at or above therecommended processing Materialsstrong bases4 of 8 Vectra Issuing Data SheetMSDS number87101000 Revision nameRevision Number0_____Hazardous Combustion or Decomposition Products:Thermal decomposition products may include oxides of nitrogen and of hazardous reactionsNo hazards to be especially Toxicological informationPotential health effectsRoutes of exposureSkin, eyes, inhalation, effectsSkinPolymer particles may cause mechanical irritation.

7 The molten Product can causeserious particles, like other inert materials, are mechanically irritating to eyesInhalationDust irritating to respiratory tract. Overheating in processing may generatehazardous, irritating toxicity by this route is expected based on the biological activity of highmolecular weight conditions which may beaggravated by exposure:No specific information available on the Product . Off-gases, which may be released ifoverheated, may affect those with chronic diseases of the respiratory data are not available. Observe the usual hygienic measures for handling Ecological InformationEcotoxicity:The effects of resin pellets on the wildlife that may ingest them is not well understood. In the case ofseabirds, some marine biologists believe that the fowl may not be able to pass plastic pellets through their digestivetracts.

8 Thus, large quantities of ingested pellets may cause intestinal blockage, false feelings of satiation or reduction inabsorption of nutrients, causing malnutrition and starvation. The goal of SPI's Operation Clean Sweep is zero loss ofpellets into the Fate/Information:This material is considered to be Do not discharge productunmonitored into the of 8 Revision nameRevision Number0 Vectra Issuing Data SheetMSDS number87101000_____13. Disposal considerationsDisposal considerationsRecycling is encouraged. Dispose of spilled material in accordance with state and local regulations for waste that is non-hazardous by Federal definition. Note that this information applies to the material as manufactured; processing, use, orcontamination may make this information inappropriate, inaccurate, or Product as shipped is not a RCRA hazardous waste under present EPA regulations14.

9 Transport informationUS Department of TransportationNot regulatedTDGNot regulatedMexico Transport InformationNot regulatedICAO/IATANot restrictedIMDGNot regulated15. Regulatory InformationUS State RegulationsChemicals associated with the Product which are subject to the state right-to-know regulations are listed along with theapplicable state(s) FEDERAL REGULATIONSTSCA Inventory:This Product complies with the Toxic Substances Control Act (TSCA).Environmental Regulations:SARA 313 ChemicalsContains no substances at or above the reporting threshold under Section 311:Acute health:NoChronic health:NoFire:NoSudden release of pressure:NoReactive:No6 of Data SheetMSDS number87101000 Revision nameRevision Number0 Vectra Issuing date_____INTERNATIONAL REGULATIONSCANADIAN REGULATIONSWHMIS Classification: Not a WHMIS controlled Ingredient Disclosure List IDL.

10 This Product does not contain substances required to be disclosed according to the Canada WHMIS IngredientDisclosure Other informationColor code(s)BLACK, VC3046, VC3065SP15, VD3002, VD3011, VE3104, VE3104K15, VF2001, VF3001, VG3010, VG3010K20,VG3042, VG3066K15, VG3161K10, VJ3009K10, VJ3040K10, VJ3129, VL3021K10, VL3043K10, VL3072, VL3072K15,VN3101, VN3101K10, VS3033K10, VS3035K10, VS3098, VS3111K10, VS3125, VS3125K15, VV3167SP10, NATURALP repared ByProduct Stewardship DepartmentCelaneseSources of key data used to compile the datasheetInformation contained in this safety data sheet is based on Celanese owned data and public sources deemed valid The absence of data elements required by ANSI or 1907/2006/EC indicates that no data meeting theserequirements is Information:Observe national and local legal requirementsExcept as otherwise noted, all of the trademarks referenced herein are owned by Ticona or its against the previous version are marked by **This Product is not intended for use in medical or dental information contained herein is accurate to the best of our knowledge.