10000 PROXIMITY PROBES & CABLES FOR 7200 …

# 1009553 REV F (October 2015) Page 1 of 2 10000 PROXIMITY PROBES & CABLES FOR 7200 SERIES (5 & 8 MM)DatasheetOVERVIEWThe 7200 series rack monitors are obsolete. But 7200 series PROXIMITY PROBES (transducers) are still on many machines in a variety of indus-tries. PROXIMITY PROBES , CABLES and drivers or transmitters are combined within a unique series and not mixed with other series (i. e., 3300, 3300 XL or the 3000 series). The lengths of the PROXIMITY PROBES and exten-sion CABLES must combine for a system length of 5 or 9 meters. All PROXIMITY PROBES /transducers have third party approvals, comply with API 670 specifications, and feature ProxMatch component coding and are ATEX approved. These PROXIMITY PROBES (transducers) are inter-changeable with the 7200 Select a probe to suit the mechanical requirements of the machine and mates with the same series extension cable and driver, or Pick an Extension cable from SAME SERIES as probe and Given the probe length, pick a cable length so the sum of probe and cable add up to the system length.

www.metrixvibration.com • info@metrixvibration.com • 281.940.1802 Doc# 1009553 • REV F (October 2015) Page 1 of 2 10000 PROXIMITY PROBES & CABLES FOR 7200 SERIES (5 & 8 MM)

Tags:

  2007, Probes, Cable, 00010, 10000 proximity probes amp cables for 7200, Proximity

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 10000 PROXIMITY PROBES & CABLES FOR 7200 …

1 # 1009553 REV F (October 2015) Page 1 of 2 10000 PROXIMITY PROBES & CABLES FOR 7200 SERIES (5 & 8 MM)DatasheetOVERVIEWThe 7200 series rack monitors are obsolete. But 7200 series PROXIMITY PROBES (transducers) are still on many machines in a variety of indus-tries. PROXIMITY PROBES , CABLES and drivers or transmitters are combined within a unique series and not mixed with other series (i. e., 3300, 3300 XL or the 3000 series). The lengths of the PROXIMITY PROBES and exten-sion CABLES must combine for a system length of 5 or 9 meters. All PROXIMITY PROBES /transducers have third party approvals, comply with API 670 specifications, and feature ProxMatch component coding and are ATEX approved. These PROXIMITY PROBES (transducers) are inter-changeable with the 7200 Select a probe to suit the mechanical requirements of the machine and mates with the same series extension cable and driver, or Pick an Extension cable from SAME SERIES as probe and Given the probe length, pick a cable length so the sum of probe and cable add up to the system length.

2 4. Choose with or without in mm [inches]Weights: kg [1 lb] for 5 m, kg [ lbs] for 5 m, kg [ lbs] for 9 m, kg [ lbs] for 9 m, armoredPROXIMITY PROBES & EXTENSION CABLES SELECTIONWEIGHT & DIMENSIONSSPECIFICATIONSP robe Tip MaterialRytonProbe Case MaterialSeries 300 SS for forward mount, smooth case and reverse mount probesProbe cable SpecsCoaxial cable with Tefzel insulation for maximum abrasion resistance with ProxMatch color & alphanumeric coding specific to a series and system length. cable Impedance95 Connector to Connector TorqueHex connector to hex connector- finger tight and 1/8 turn with wrenches. Hex connector to click type connector- finger tight plus 1/8 turn with wrench & pliersTensile Strength75 lbf. probe case to probe lead. 60 lbf. probe pigtail to connector and 60 lbf.

3 Con-nectors to extenstion / cable ArmorSeries 300 SS, flexible, connected to probe body with case internal Bend Radius1 inch without armorTarget Material4140 steel (standard)Probe & Extension cable Temperature Range-40 C to +177 C (-40 F to +351 F)Probe PressureStandard probe design includes seal between probe tip and case and is not pressure tested before shipment. If pres-sures are present, contact the factory for possible high pressure probe designs. Relative Humidity100% condensing but not submersible and with connectors properly protected. Connector MaterialGold plated brass hex connectorsJAM NUTTIP LENGTHSTAINLESS STEEL4 WRENCH FLATSUNTHREADEDLENGTHW eight: kg [1lb]UNTHREADEDLENGTHCASELENGTH15(.60)ST AINLESS STEEL7/16" HEXTIP CONNECTOR (FEMALE)OPTIONAL STAINLESS STEEL ARMORMAX.

4 DIA. [.325]COAXIAL CONNECTOR (MALE) [.28] cable LENGTH300 [12]TYPICALW eight: kg [ lb], kg [1 lb], armoredREVERSE MOUNT PROBECABLESTANDARD # 1009553 REV F (October 2015) Page 2 of 2 ORDERING INFORMATION* Reverse MountUse a standard straight-through threaded probe or the reverse mounted probe and stinger depending on availability of the cable FOR 7200 SERIES 7402-AAA-BBCable length AAA040= m045= m080= m085= mArmor BB00 = NO01 = YESE xample transducer configurationGiven: A 5 meter system, in. case length 3/8-24 probe,1 meter long, 0 , no armor on probe, armored cable , driver w/DIN mount. Use: Probe: 10005-00-30-10-02 Extension cable : 7402-040-01 Model 5499IS REQUIREDfor mounting reverse mount probesunthreadedcase lengthprobe lengthunthreadedcase lengthSTANDARD PROXIMITY PROBE 1 0 0 X X - A A - B B - C C - 0 2 Model DiameterCase ThreadsUnthreaded LengthAACase LengthBBProbe LengthCCArmor100015 mm1/4"-28 Increments of case length minus 1 in.

5 (min)05= in. (delta)30= 3 in. (standard)95= in. (max)Even increments only05 = m m10 = m mNo10002 Yes100058 mm3/8"-24No10006 Yes100035 mmM8X1 Increments of 10 case length minus 20 20mm. (min)07= 70mm. (standard)25= 250mm. (max)No10004 Yes100078 mmM10X1No10008 Yes10026*8 mm3/8 -2402= *M10X105= 5 30