Example: quiz answers

125 PSI Hot Water Boilers Atmospheric / Natural Gas Fired

125 PSI Hot Water BoilersAtmospheric / Natural Gas FiredPRODUCT DESCRIPTION Rite Atmospheric Natural Gas Fired Watertube Boilers are found at the heart of better engineered closed-loop heating systems all over North America. From conventional space heating systems to heat pumps to industrial process loads, Rite offers 47 basic models, ranging from 480 to 12,499 MBH Input (11 300 boiler Horsepower). These heavy duty, long lasting Boilers have been providing heat to schools, churches, commercial buildings, metal finishers and silicone chip makers (to name a few) Safely and reliably for nearly fifty years. So simple to maintain and operate, Rite Boilers feature complete waterside access so that virtually all scale and mud deposits can be seen and mechanically cleaned during a single scheduled maintenance shutdown.

125 PSI Hot Water Boilers Atmospheric / Natural Gas Fired PRODUCT DESCRIPTION Rite Atmospheric Natural Gas Fired Watertube Boilers are found at …

Tags:

  Water, Natural, Fired, Boiler, Atmospheric, Water boilers atmospheric natural gas fired

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 125 PSI Hot Water Boilers Atmospheric / Natural Gas Fired

1 125 PSI Hot Water BoilersAtmospheric / Natural Gas FiredPRODUCT DESCRIPTION Rite Atmospheric Natural Gas Fired Watertube Boilers are found at the heart of better engineered closed-loop heating systems all over North America. From conventional space heating systems to heat pumps to industrial process loads, Rite offers 47 basic models, ranging from 480 to 12,499 MBH Input (11 300 boiler Horsepower). These heavy duty, long lasting Boilers have been providing heat to schools, churches, commercial buildings, metal finishers and silicone chip makers (to name a few) Safely and reliably for nearly fifty years. So simple to maintain and operate, Rite Boilers feature complete waterside access so that virtually all scale and mud deposits can be seen and mechanically cleaned during a single scheduled maintenance shutdown.

2 The result Better fuel efficiency and lower operating cost over the life of your boiler investment. Consider a few of our other standard features: Floating heads that eliminate pressure vessel cracks and broken welds caused by thermal stress cycling (backed by Rite s 25 year Thermal Shock Warranty), Single Stacks on models to 7,500,000 BTUH input, Top supply and return Water connections, Rugged Heat Exchangers with minimal pressure drop at normal flow rates can also handle the boiler firing under no flow conditions, Rite s bolted/gasketed headplates that eliminate any possibility of hydraulic explosion in the event that safety devices fail and you have a better boiler by ENGINEERING & MFG.

3 CORP. COMMERCE, CALIFORNIA 90040 PHONE (562) 862-2135 FAX (562) 2/2014 Rite Atmospheric Boilers are an excellent choice when: Low NOx emissions are not required, Natural gas will be the only fuel used, the installation is indoors (See our line of weatherproof models for outdoor applications), and when lower combustion efficiencies at less than full firing rate are acceptable. Atmospheric burners are far less expensive than power burners, so when the above criteria is met, then Atmospherics are a strong economical alternative to Rite s outstanding line of power burner Fired Water Boilers . Other factors favoring Atmo-spherics are: Extremely low electrical power consumption (no energy hogging fan motors), Rapid start-up on demand (No pre-purge blower fan), Lighter weight, Lower height, and Whisper-quiet burner Atmospheric BURNER FEATURES125 PSI Water Heating Boilers / AtmosphericModels & Ratings / Natural Gas FiredRev.

4 2/2014 STACK / DRAFT REQUIREMENTS UL listed for use with Type B Vent. Minimum stack height including Draft Control is 10 feet. The stack should be supported independently of the boiler and an adjustable length section of stack should be installed after the draft control to allow for future separa-tion. All Rite Boilers have internal stack supports to handle the weight of the stack during installation. Boilers with barometric damper draft control should draft between to when firing. Boilers with draft diverters will draft between to A draft gauge is installed on all Boilers equipped with barometric dampers to help set and maintain the REQUIREMENTSA dequate Combustion/Ventilation Air is vital for safe, efficient operation.

5 Refer to the latest edition of the Uniform Mechanical Code or consult your local Building and Safety Depart-ment for specific requirements. Warning: Do not install in a room that will develop negative pressure without utilizing a properly sized induced draft REQUIREMENTS A Single Point 120/60/1 8 amp supply to the electrical GAS SUPPLY REQUIREMENTS (STATIC AND AT FLOW) Models 48 W * - 76 W * 6 min. to 14 max. Models 85 W * - 400 W * 7 min. to 14 max. Models 425 W * - 750 W * 15 min. to 28 max. Models 840 W * - 1250 W * 20 min. to 28 max. For other gas pressures, consult factory or your Rite Representative.

6 *Propane Supply Requirements: 11 min. to 14 Water TEMPERATURES & PRESSURE DROPS Minimum return Water temperature is 135 F (after start-up). Lower temperature return factory options available. Maximum practical supply Water temperature is 235 F. Higher temperature/pressure Rite Boilers available. Pressure drop for all models is less than 3 feet of total DERATIONR atings given below are for elevations up to 2000 feet. Above 2000 feet, ratings should be reduced at the rate of 4% for every 1000 feet above sea FORMULA BTU Output @ 0-2000 elevation = 60 x x T x 20 F 100 F RiseNominalShippingWeight (lbs)MBHB oilerHorsepower48 W480384112400492138465108055 W550440132750562344535128563 W630506153162632451615139076 W7606081838007527617401530A90 W900720214500893172875170085 W850680204250884069830173590 W9007202145008840728751735105 W1050840255250101438410151865120 W1200960286000115479711652000135 W135010803267501315011013152140150 W150012003575001455412014602265165 W165013203982501595713516002400180 W180014404390001746114517502510200 W2000160047100001926616019502700A150 W150012003575001607112014602430A165 W165013203982501687513516002550A180 W180014404390001907914517502735A200 W2000160047100002058316019502960225

7 W2250180053112502308918021903160250 W2500200059125002529420024303365275 W27502200651375027310022026703590300 W30002400711500029510524029203815325 W32502600771625031811126531604040350 W35002800831750034011628534004265375 W37503000891875036212230536504490400 W40003200952000038312732539004715425 W425034001012125040513334541404940450 W450036001072250042813936543805160475 W475038001132375045014538546305385500 W500040001192500047315140548705610550 W550044001312750052619044553706120600 W600048001433000057421348558506630A650 W650052001553250062224052062507040A700 W700056001673500067025556067207550A750 W750060001803750072227060072008060A400 W40003200952000039016032539004900A450 W450036001072250044018036543805360A500 W500040001192500048619540548705815A550 W550044001312750053521544553706275A600 W600048001433000058423548558506760650 W650052001553250063225052062507245700 W700056001673500068027556067207750750 W750060001803750073029060072008240840 W840067002004187580032065078008670940 W9400750022546875900345770927092801050 W105008400250525001000370810974099451150 W115009200275575001100395925110001050012 50 W12499999930062494120042010051210011220 DIMENSIONS ARE IN INCHES - SUBJECT TO PRODUCTION TOLERANCES AND CHANGE WITHOUT NOTICE.

8 CERTIFIED DIMENSIONS AVAILABLE UPON REQUEST. Boilers APPROVED FOR INSTALLATION ON NON-COMBUSTIBLE FLOORS PSI Water Heating Boilers / AtmosphericModels & Dimensions / Natural Gas FiredRev. 2 Control(Space Req d.) W4026485799 (33)-403/42 MNPT2 MNPT1012055 W452648571010 (34)-4512 MNPT2 MNPT1012063 W502648571010 (34)-5012 MNPT2 MNPT1012076 W582648571212 (36)-5812 MNPT2 MNPT10120A90 W682648571212 (36)-6812 MNPT2 MNPT1012085 W463252611212 (36)-4613 FL3 FL121 1/42690 W463252611212 (36)-4613 FL3 FL121 1/426105 W523252611414 (38)-5213 FL3 FL121 1/426120 W583252611414 (38)-581 1/43 FL3 FL121 1/426135 W643252611412 BARO-641 1/43 FL3 FL121 1/426150 W703252611412 BARO-701 1/43 FL3 FL121 1/426165 W763252611412 BARO-761 1/43 FL3 FL121 1/426180 W823252611614 BARO-821 1/43 FL3 FL121 1/426200 W903252611614 BARO-901 1/23 FL3 FL121 1/426A150 W554257661412 BARO-551 1/44 FL4 FL141 1/234A165 W594257661412 BARO-591 1/44 FL4 FL141 1/234A180 W654257661614 BARO-651 1/24 FL4 FL141 1/234A200 W694257661614 BARO-691 1/24 FL4 FL141 1/234225 W734257661816 BARO-731 1/24 FL4 FL161 1/234250 W794257661816 BARO-7924 FL4 FL161 1/234275 W854257661816 BARO-8524 FL4 FL161 1/234300 W914257662018 BARO-9124 FL4 FL161 1/234325

9 W974257662018 BARO-9724 FL4 FL161 1/234350 W1034257662018 BARO-10324 FL4 FL161 1/234375 W1094257662018 BARO-10924 FL4 FL161 1/234400 W1154257662220 BARO-11524 FL4 FL161 1/234425 W1214257662220 BARO-12124 FL4 FL161 1/234450 W1274259682220 BARO-12724 FL4 FL161 1/234475 W1334259682420 BARO-13324 FL4 FL161 1/234500 W1394259682420 BARO-13924 FL4 FL161 1/234550 W1095164732624 BARO-1092 1/24 FL4 FL16244600 W1185164732624 BARO-1182 1/24 FL4 FL16244A650 W1295164732824 BARO-1292 1/25 FL5 FL16244A700 W1385164732824 BARO-1382 1/25 FL5 FL16244A750 W1475164733028 BARO-1472 1/25 FL5 FL16244A400 W796363722220 BARO-7924 FL4 FL16256A450 W876363722220 BARO-8724 FL4 FL16256A500 W956363722420 BARO-9524 FL4 FL16256A550 W1026363722624 BARO-1022 1/24 FL4 FL16256A600 W1096363722624 BARO-1092 1/24 FL4 FL16256650 W1176363722824 BARO-1172 1/25 FL5 FL16256700 W1246363722824 BARO-1242 1/25 FL5 FL16256750 W1326363723028 BARO-1322 1/25 FL5 FL16256840 W115776372(2) 24(2) 20 BARO231152 1/26 FL6 FL18269940 W128776372(2) 24(2) 20 BARO261282 1/26 FL6 FL182691050 W140776372(2) 26(2) 24 BARO291402 1/26 FL6 FL182691150 W152776372(2) 26(2) 24 BARO321522 1/26 FL6 FL182691250 W164776372(2) 26(2)

10 24 BARO351642 1/26 FL6 FL18269 TOP VIEWRIGHT SIDE VIEWREAR VIEWD raft Diverters are supplied standard on Models 48W-120W only. Barometric Dampers will be shipped one size smaller than D dimension for stacks up to 25 feet of vertical height (as shown below in column E), full size (same as D dimension) for stacks 25 to 50 feet tall and one size larger for stacks over 50 feet tall. Barometic Damper Tee by vary - sizes shown are for UL gas trains at standard supply pressures. Gas connections are male NPT pipe thread. All other threaded connections are female NPT except where are ANSI 150 lb SA-105 flat right hand construction shown illustrated above.


Related search queries