Example: marketing

1336 PLUS II Adjustable Frequency AC ... - Rockwell …

1336 PLUS IIAdjustableFrequencyAC DriveTechnical Data2 Available in ratings from to 448 kW ( to 600 horsepower), the drive helps to provide a singlesolution for virtually all of your speed control requirements. Commonality of design across the entirerange, coupled with identical control interface functions, device communications, training andmaintenance, provide you with a tremendous advantage in your control needs. Add that to integrationwith Allen-Bradley SMC and SMP power products, the 1305 drive, the1336 IMPACT and 1336 FORCE field-oriented control drives (all of whichuse the same control interface and communication options) and you ve justgained significant advantage in system design, component integration,operator training and Complete Line of Drives for aComplete Family of Products3 Table of Contents1336 PLUS IIProduct DataProduct and Parameter PLUS II 20 (NEMA Type 1) 65/54 (NEMA Type 4/12) 20 (NEMA Type 1) Bottom View Supply Wiring and Signal Wiring.

500-600V AC. The 1336 PLUS II is a micro-processor based adjustable frequency PWM AC drive. Its advanced design provides exceptional reliability when controlling 3-phase motors. The output can be tuned to provide optimum performance for virtually any load condition. Selectable or V/Hz operation provides outstanding motor control.

Tags:

  Micro, Rockwell, 3136

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1336 PLUS II Adjustable Frequency AC ... - Rockwell …

1 1336 PLUS IIAdjustableFrequencyAC DriveTechnical Data2 Available in ratings from to 448 kW ( to 600 horsepower), the drive helps to provide a singlesolution for virtually all of your speed control requirements. Commonality of design across the entirerange, coupled with identical control interface functions, device communications, training andmaintenance, provide you with a tremendous advantage in your control needs. Add that to integrationwith Allen-Bradley SMC and SMP power products, the 1305 drive, the1336 IMPACT and 1336 FORCE field-oriented control drives (all of whichuse the same control interface and communication options) and you ve justgained significant advantage in system design, component integration,operator training and Complete Line of Drives for aComplete Family of Products3 Table of Contents1336 PLUS IIProduct DataProduct and Parameter PLUS II 20 (NEMA Type 1) 65/54 (NEMA Type 4/12) 20 (NEMA Type 1) Bottom View Supply Wiring and Signal Wiring.

2 40 General Wiring Block Block Supplied PLUS IIRemote Device PLUS IISELECTION Number Torque Drives and Brake Installed Installed Packaged Drives DescriptionDiagnosticsFeaturesProtective Detection and Trip:UndervoltageOvervoltageDrive OvercurrentOvertemperatureExternal SignalDrive Output ShortGround FaultEncoder LossAt temperatureLoad LossSingle Phase Overcurrent Stall Overvoltage Stall Six Drive Alarms Fault Reset InputSpecial Function Auto Economizer Process PI Controller Traverse Function Selectable Fault Reset & Run Auto Restart on Power Up Speed Sensitive ElectronicOverload Auto-tuning Step LogicOperational Control Selectable Volts/Hertz Mode Multi-lingual selectionProgrammable Dual Accel/Decel Profiles Three Skip Frequencies DC Injection Braking Dynamic Braking Slip Compensation Negative Slip Compensation(Droop)

3 S Curve Accel/Decel Profile Line Loss Restart Mode Proactive Current Limit Last Four Event Fault Memory Flying Start Seven Preset SpeedsI/O Interface Control Output Contacts(2) Form A ( )(2) Form C ( - )Programmable to 17different drive variables. Flexible AnalogInputs/Outputs Pulse Train Input Encoder Feedback ClosedLoop Speed Control High Speed InputReal time preventive maintenance coupled with customized status and fault upon your particular drive configuration, status andfault conditions can be reported through the Human InterfaceModule or through the SCAN port Communications Port. Faultdiagnostic routines are started each time the 1336 PLUS II ispowered up. Throughout the entire run sequence, the drive willcontinue to look for potential fault conditions. To allow real-time preventive maintenance, drive output currentand control conditions can be selectively monitored while the driveis running.

4 The operator is made aware of alarm conditions such ascurrent limit, bus voltage status, motor overload or drive overloadbefore the drive reaches a fault level. Should a fault occur, plainlanguage diagnostic messages will help identify and isolate theproblem, allowing personnel to take quick, corrective s (Insulated Gate Bipolar Transistors) Quiet motor operation through programmable carrier Frequency . Third Generation devices Reduced switching and conduction losses. Used on complete line kW ( HP).Status status indicators located on the control Current Control Multiple sensors. Exceptional torque production throughControl. Proactive current limit control Reduces trips. Ability to start low inductance Listed for dual andCanadian Certification. Designed to meet EN, IEC, VDE and otherinternational Power and Logiceliminates noise to provide reliableand stable Cooling Fanon many ratings eliminates the need for atransformer and voltage tapping.

5 Accommodates global Logic Supply from DC Busdoes not require separatecontrol power wiring, improved ride-thru Designed to accommodate on-boardcommunications for all sizeconserves expensive panel Constructioneliminates most internal cables and Bus Designreduces internal inductance, therebyreducing snubber losses and improving IGBT Human Interfaceprovides simplicity of programmingand flexibility of Dissipation and extensive infra-red testing minimizes hot spots to maximize and European for acceptabilitythroughout the 65 & 54 (NEMA Type 4 & 12)configurations accommodated with heat sink through the back DescriptionDriveTools, PLC, SLC and SCAN port are registered trademarks of Rockwell 1336 PLUS IIThe standard solution to your application 1336 PLUS IIprovides ratings from kW ( HP)in three voltage ranges 200-240V AC, 380-480V AC and 500-600V AC.

6 The 1336 PLUS IIis a micro -processor basedadjustable Frequency PWM AC drive. Its advanced design providesexceptional reliability when controlling 3-phase motors. The outputcan be tuned to provide optimum performance for virtually any loadcondition. Selectable or V/Hz operation providesoutstanding motor and programming simplicity is evident in: Condensed packagingthat allows for easy mounting, installation and wiring in all types of applications. Common assembly partsthat reduces the need to stock a multitude of parts. Easy to program parametersthat are organized in a group and element structure for quick access to related functions. Simple tuningfor optimum torque performance. An easy to read Supertwist Liquid Crystal Displaygives 2 lines of 16 characters each for easy one finger programming and drive monitoring.

7 Serial communicationsthat provide easy integration and access to peripheral equipment Fully compatiblewith all Allen-Bradley PLC or SLC equipment. Common optionsthat are used throughout the entire family of programmable to help provide precise andaccurate l336 PLUS IIuses digitally programmable features to achieveprecise and consistentlyaccurate control, setup and operation. The drive can be programmed locally from the Human InterfaceModule or through a serial communications port using a PLC, SLC,or DriveTools programming I/O allows simple connection to manycustomer preformed control inputs and outputs can be programmed to meet nearlyevery application algorithms provide acceleration and running torque in excess of 250%combined with a constanttorque speed range of 120:1 allow the1336 PLUS IIto handle the tough applications other drives can t.

8 6 Specifications200-240V Drive380-480V Drive500-600V DriveAC Input Overvoltage Trip285V AC570V AC690V ACAC Input Undervoltage Trip138V AC280V AC343V ACBus Overvoltage Trip405V DC810V DC1013V DCBus Undervoltage Trip200V DC400V DC498V DCNominal Bus Voltage324V DC648V DC810V DCHeat Sink ThermistorMonitored by microprocessor overtemp Overcurrent TripSoftware Current Limit:20 to 160% of VT rated Current Limit:180 to 250% of VT rated current (dependent on drive rating).Instantaneous Current Limit: 220 to 300% of VT rated current (dependent on drive rating).Line transientsUp to 6000 volts peak per IEEE Logic Noise ImmunityShowering arc transients up to 1500 volts Ride-Thru15 milliseconds at full load (refer to Page 13).Logic Control seconds minimum, 2 seconds typical (refer to Page 13).Ground Fault TripPhase-to-Ground on Drive Circuit TripPhase-to-Phase on Drive m (3300 ft) maximum without derating.

9 (refer to the Derating Guidelines on Pages 56-60).Ambient Operating TemperatureIP00, Open:0 to 50 degrees C (32 to 122 degrees F).IP20, NEMA Type 1:0 to 40 degrees C (32 to 104 degrees F).IP54, NEMA Type 12:0 to 40 degrees C (32 to 104 degrees F).IP65, NEMA Type 4:0 to 40 degrees C (32 to 104 degrees F).(refer to the Derating Guidelines on Pages 56-60).Storage Temperature (all constructions)- 40 to 70 degrees C (- 40 to 158 degrees F).Relative Humidity5 to 95% peak for 11 ms duration ( ms). inches ( mm) displacement, 1G ListedCSA CertifiedMarked for all applicable directives1 EmissionsEN 50081-1EN 50081-2EN 55011 Class AEN 55011 Class BImmunityEN 50082-1EN 50082-2 IEC 801-1, 2, 3, 4, 6, 8 per EN 50082-1, 2 Low VoltageEN 60204-1 PREN 50178 ULC QETNOCDNI6L65 DETSILUL QETNOCDNI6L65 DETSIL1 Note: Installation guidelines called out in Appendix C of the 1336 PLUS IIUser Manual (publication 1336 ) must be adhered SpecificationsEnvironmental Specifications7 SpecificationsInput DataVoltage Tolerance: 10% of Minimum, +10% of Tolerance:48-62 Phases:Three-Phase input provides full rating for all operation is possible for A & B Frame drives at a derating of 50%.

10 (refer to frame designations on Page 22and the Derating Guidelines on Pages 56-60).Displacement Power FactorA1 - A3 Standard, with Optional Frame & at rated amps, nominal line Short Circuit Current Rating200,000A rms symmetrical, 600 volts (when used with AC line fuses specified on Page 37).MethodSine coded PWM with programmable carrier Frequency . Ratings apply to all Frame2-10 kHz. Drive Rating based on 4 Frame2-8 kHz. Drive Rating based on 4 & D Frame2-6 kHz. Drive Rating based on 4 Frame & Up2-6 kHz. Drive Rating based on 2 kHz.(refer to frame designations on Page 22and the Derating Guidelines on Pages 56-60).Output Voltage Range0 to rated Frequency Range0 to 400 AccuracyDigital Input:Within of set output Input:Within of maximum output Motor Controlcontrol with full tuning.


Related search queries