Reference Manual MicroLogix 1400 programmable Controllers Catalog Numbers 1766-L32 BWA, 1766-L32 AWA, 1766-L32 BXB, 1766-L32 BWAA, 1766-L32 AWAA, 1766-L32 BXBA. Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication available from your local Rockwell Automation sales office or online at ) describes some important differences between solid-state equipment and hard-wired electromechanical devices.

Reference Manual MicroLogix 1400 Programmable Controllers Catalog Numbers 1766-L32BWA, 1766-L32AWA, 1766-L32BXB, …

Tags:

  Controller, 0041, Micrologix, Programmable, P micrologix 1400, Micrologix 1400 programmable controllers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1766-RM001D-EN-P MicroLogix 1400 …

1 Reference Manual MicroLogix 1400 programmable Controllers Catalog Numbers 1766-L32 BWA, 1766-L32 AWA, 1766-L32 BXB, 1766-L32 BWAA, 1766-L32 AWAA, 1766-L32 BXBA. Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication available from your local Rockwell Automation sales office or online at ) describes some important differences between solid-state equipment and hard-wired electromechanical devices.

2 Because of this difference, and also because of the wide variety of uses for solid-state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc.

3 Cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.

4 ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. IMPORTANT Identifies information that is critical for successful application and understanding of the product.

5 Allen-Bradley, Rockwell Automation, MicroLogix , RSLinx, RSLogix 500 and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Summary of Changes To help you locate new and updated information in this release of the manual, we have included change bars as shown to the right of this paragraph. Firmware Revision Features are added to the controllers through firmware upgrades. See the latest release notes, 1766-RN001, to be sure that your controller 's firmware is at the level History you need.

6 Firmware upgrades are not required, except to allow you access to the new features. See Firmware Upgrades below. Firmware Upgrades Enhanced features are added to the controllers through a firmware upgrade. This firmware upgrade is not required, except to allow you access to the latest features and corrected anomalies. You can only upgrade firmware within the same series of controller . To use the newest features, be sure your controller 's firmware is at the following level: programmable Firmware Revision Catalog Numbers controller MicroLogix 1400 OS Series A FRN 6, Boot 1766-L32 AWA, 1766-L32 BWA, 1766-L32 BXB, Series A FRN 1 1766-L32 AWAA, 1766-L32 BWAA and 1766-L32 BXBA controllers OS Series B FRN 10, Boot Series B FRN 3.

7 To upgrade the firmware for a MicroLogix controller visit the MicroLogix web site at In order to use all of the latest features available with OS Series A controllers, RSLogix 500/RSLogix Micro programming software must be version or higher. For Series B controllers, this should be version or higher. iii Publication 1766-RM001D-EN-P - September 2011. iv Summary of Changes Notes: Publication 1766-RM001D-EN-P - September 2011. Table of Contents Summary of Changes Firmware Revision History .. iii Firmware Upgrades .. iii Preface Who Should Use this Manual.

8 Xi Purpose of this Manual .. xi Common Techniques Used in this Manual.. xi Related Documentation .. xii Rockwell Automation Support .. xii Chapter 1. I/O Configuration Embedded I/O .. 2. MicroLogix 1400 Expansion I/O .. 2. MicroLogix 1400 Expansion I/O Memory Mapping .. 3. I/O Addressing .. 12. I/O Forcing .. 13. Input Filtering .. 14. Analog Inputs .. 15. Analog Outputs.. 17. Latching Inputs .. 17. Configure Expansion I/O Using RSLogix 500/RSLogix Micro.. 21. Chapter 2. controller Memory and File controller Memory .. 23. Types Data Files.

9 28. Protecting Data Files During Download .. 30. Static File Protection .. 32. Password Protection.. 33. Clearing the controller Memory .. 34. Allow Future Access Setting (OEM Lock).. 35. Web View Disable .. 35. LCD Edit Disable .. 36. Chapter 3. Function Files Overview .. 37. Real-Time Clock Function File .. 38. RTA - Real Time Clock Adjust Instruction .. 41. Memory Module Information Function File .. 42. Base Hardware Information Function File .. 44. Communications Status File .. 45. Ethernet Communications Status File .. 61.

10 V Publication 1766-RM001D-EN-P - September 2011. vi Table of Contents Input/Output Status File .. 69. Chapter 4. Programming Instructions Instruction Set.. 71. Overview Using the Instruction Descriptions .. 72. Chapter 5. Using the High-Speed High-Speed Counter Overview .. 79. Counter and programmable programmable Limit Switch Overview.. 79. High-Speed Counter (HSC) Function File .. 80. Limit Switch High-Speed Counter Function File Sub-Elements Summary.. 82. HSC Function File Sub-Elements .. 83. HSL - High-Speed Counter Load.


Related search queries