Example: barber

1985 MAK block Goltens Miami 3-7-13 - LOCK-N …

Final report LOCK-N -STITCH Inc. Page 1 of 6 LOCK-N -STITCH Inc. Casting Repair Specialists 1015 S. Soderquist Rd. Turlock CA 95380 Final report Date: 3-7-13 Part: 1985 MAK engine block Serial number: 40096 800-736-8261 209 632-2345 Fax 209-632-1740 1. Base metal cast iron X ductile iron cast steel cast aluminum other _____ 2. Machinability X no previous repairs arc-welded brazed heat-related cracks other _____ 3. Casting shape where cracked X flat X inside/outside corner X radius other _____ 4. Cause of damage X impact heat freezing normal operation other _____ 5. Length of crack/s 35 @ 13 @ 1 6 @ 1 6.

Final report LOCK-N-STITCH Inc. Page 2 of 6 13. Inspection method(s) Visual, prepared bath and dye penetrant 14. Damage repaired:

Tags:

  Block, 8519, 1985 mak block

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1985 MAK block Goltens Miami 3-7-13 - LOCK-N …

1 Final report LOCK-N -STITCH Inc. Page 1 of 6 LOCK-N -STITCH Inc. Casting Repair Specialists 1015 S. Soderquist Rd. Turlock CA 95380 Final report Date: 3-7-13 Part: 1985 MAK engine block Serial number: 40096 800-736-8261 209 632-2345 Fax 209-632-1740 1. Base metal cast iron X ductile iron cast steel cast aluminum other _____ 2. Machinability X no previous repairs arc-welded brazed heat-related cracks other _____ 3. Casting shape where cracked X flat X inside/outside corner X radius other _____ 4. Cause of damage X impact heat freezing normal operation other _____ 5. Length of crack/s 35 @ 13 @ 1 6 @ 1 6.

2 Material thickness See above 7. Operating pressure 4 bar in water jacket Final report LOCK-N -STITCH Inc. Page 2 of 6 13. Inspection method(s) Visual, prepared bath and dye penetrant 14. Damage repaired: 8. Operating temperature 180 _____ _____ 9. Working environment hot cold safety concerns describe: _____ _____ _____ X other Excellent 10. Remachining requirements bolt holes bearing bores machined surfaces X other Goltens to complete final machining 11. Customer s needs X permanent repair temporary repair turnaround time describe: _____ _____ _____ other _____ 12.

3 Accessibility room for the tools? room for the operator/s? need for disassembly? describe: good_____ _____ _____ Final report LOCK-N -STITCH Inc. Page 3 of 6 Final report LOCK-N -STITCH Inc. Page 4 of 6 Final report LOCK-N -STITCH Inc. Page 5 of 6 Final report LOCK-N -STITCH Inc. Page 6 of 6 Conclusion: Repair completed on March 4, 2013.

4 Customer technicians watched and assisted in this repair.