US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelApplications:D2Z Panelboards are designed specifically for use in: Class I, zone 1 , Division 2, Groups A, B, C, D hazardous arealocations. In damp, wet or corrosive locations. Indoors or outdoors in zone 1 , Division 2 areas of petroleumrefineries, chemical and petrochemical plants, and other processindustry : cCSAus, PTB* certified for Class I, zone 1 , Division 2 hazardousareas. Fiberglass-reinforced polyester enclosures:Non-metallic, corrosion-freeIncreased safety Ex-e protectionImpact resistantNEMA 4X, IP65 Enclosure meets UL 94-VOUV listed 316L stainless steel enclosures (suffix S860):Corrosion resistantIndustrial grade thicknessNEMA 4X, IP65 Unique design allows for panels with more than 42 circuits.

1A www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 655 D2Z Panelboards 1A Zone 1, Division 2 Non-metallic ...

Tags:

  Division, Zones, Panelboard, Zone 1, D2z panelboards zone 1, Division 2, D2z panelboards

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1A D2Z Panelboards Zone 1, Division 2 Cl. II, Div. 1 ...

1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelApplications:D2Z Panelboards are designed specifically for use in: Class I, zone 1 , Division 2, Groups A, B, C, D hazardous arealocations. In damp, wet or corrosive locations. Indoors or outdoors in zone 1 , Division 2 areas of petroleumrefineries, chemical and petrochemical plants, and other processindustry : cCSAus, PTB* certified for Class I, zone 1 , Division 2 hazardousareas. Fiberglass-reinforced polyester enclosures:Non-metallic, corrosion-freeIncreased safety Ex-e protectionImpact resistantNEMA 4X, IP65 Enclosure meets UL 94-VOUV listed 316L stainless steel enclosures (suffix S860):Corrosion resistantIndustrial grade thicknessNEMA 4X, IP65 Unique design allows for panels with more than 42 circuits.

2 Main disconnect switches 40, 80, 125, 180A. Optional flameproof Ex-d fusing of main disconnect. Flameproof Ex-d encapsulated UL 489 branch circuit breakers:Thermal-magnetic protection up to 40A with 240 VAC circuit protection up to 25A with 480 VAC circuit contacts (mechanical or electrical).**Lockout on to Increase Safety terminal branch breakers (EPDs).** Clear, NEMA 4X / IP65 window, hinged for actuation or breakers. Double lockout on windows and breakers. Brass plates for hub or cable gland entries. Enclosures are to be vertically mounted on switchrack frames orwalls. Completely pre-wired ready for connection to terminal :The following special options are available from the factory byadding the suffix to the Cat. #:DescriptionSuffixD2Z Series Panelboards are now available with 316L stainlesssteel enclosures. This material is ideal for wash down andcorrosive areas requiring product endurance in adverselocations.

3 S860*Available with ATEX certification, please consult factory.**Available with only UL 1077 supplemental protectors.**For ambients -20 C or less, optional heater is with fiberglass-reinforced polyester enclosureD2Z with 316L stainless steel enclosure (suffix S860)Cl. I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Certifications and Compliances*:CertificationscCSAusDegree of ProtectionNEMA 4 XIP65 to IEC 60529UV ResistanceISO 4892 Enclosure MaterialGlass-reinforced polyesterTemperature Ratings-55 C to 40 C**Rated Voltage480 VACR ated CurrentMax. 180A NEC:Class I, Division 2, Groups A, B, C, DClass I, zone 1 , Group IIC CEC:Class I, Division 2, Groups A, B, C, DClass I, zone 1 , Group IICC lass II, Division 1, Groups E, F, G UL Standards: UL60079-0UL60079-1UL60079-7UL60079-18 CSA Standards: US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelBranch Circuit Breakers1-pole, 2-pole, 3-pole, 4-pole; with EPD protection 1-pole + Neutral,2-pole; 2, 6, 10, 16, 20, 25, 32 and 40 AmpsExplosion ProtectionEx de IIC AEx de IIC Class I, zone 1 , Div.

4 2, Groups A, B, C, DClass II, Div. 1, Groups E, F, GCertificationscCSAusRated Operating VoltageUp to max. 480 VACR ated CurrentUp to 40 ARated Switching Capacity10k AlCCircuit Breaker CharacteristicsUL489 Circuit BreakersTripping Characteristics"Z" or "K"*Tripping Current for EPDs30mA (up to 300mA on request)Circuit Breaker Enclosure MaterialsFiberglass-reinforced epoxyOptional Auxiliary/Signal Contacts**Rated Voltage250 VACR ated Current5A* "Z" Branch breakers are used for all general applications such as lighting and heat "K" breakers are used for MOVs and portable power. Contact factory for other application.** Aux contacts indicate mechanical or electrical trippingSignal contacts indicate only electrical tripping and are used primarily on heat-tracing breakers with signal contacts require next larger breaker Disconnect Switch 40, 80, 125, 180A, 4-poleExplosion ProtectionEx de IIC T6 AEx de IIC T6 Class I, zone 1 , Div.

5 2, Groups A, B, C, DClass II, Div. 1, Groups E, F, GRated Operating VoltageUp to 690 VACM otor Switching Capacity AC3**Type230V400V500V690V40A40A40A40A32A 80A80A80A80A63A125A125A125A125A110A180A1 80A180A150A125A**See IEC I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Technical Data Large windowspermit easy viewing andquick access to breakers withoutopening the enclosures. Lockoutsstandard for both windowsand breakers Up to 6 single-pole breakerscan beinstalled under one window. NEMA 4X, IP65 protection. Window lockswith 5/16" (8mm) Allen Switch 40A main switch, 4-pole, optional fusingin enclosure with window(s). 80, 125 and 180A main switch, 4-pole,optional fusing in US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelMain Fuse, type NHStandard EntriesBrass gland platewith zone 1 Myersadapter hubs: (STM series)Metric Entries(remove hubs)Main supply(1) 2" + (3) 1"(1) M63 + (3) M32 Branches(9) 3/4"(9) M25 Universal Wiring zone 1 Myers adapter hubs for conduit or Terminator cable glands.

6 Stainless Steel Hubs available I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de IIC T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Main Fuse, 3-poleExplosion ProtectionEx de IIC AEx de IICC lass I, zone 1 , Div. 2, Groups A, B, C, DRated Operating VoltageUp to max. 500 VACR ated CurrentCurrentTemperature Class in Board25AT635AT550AT463AT480AT4100AT4125A T4 Recommended manufacturer: Eaton's Bussmann type NH00G fuses for general useor N00M for motor Amperage (Fuses not provided) US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelCl. I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 SpecOne D2Z panelboard Construction LayoutExample of D2Z distribution panel with built-in components underthe window.

7 (available mounting width = 213mm)D2Z panel with 3 mounting spaces1 Mounting Space 190mm2 Mounting Space 190mm3 Mounting Space 190mm4(2) 4 pole breakers width 106mm each (available mounting width 213mm)5(3) 3 pole breakers width 70mm each (available mounting width 213mm)6(4) 2 pole breakers width 53mm each (available mounting width 213mm)7(6) 1 pole breakers width 35mm each (available mounting width 213mm)840A main switch, 4-pole. 1 mounting space required9 Main fuse. 1 mounting space required in place of 1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelCl. I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Ordering ProcedureStep 1: WindowDetermine the number of windows required from the following chart based on the number of branch breakers.

8 Multiply breaker space bynumber of breakers. Round the sum total to the next highest whole number to determine required windows. For (8) 1-pole and (2) 2-polebreakers: (8 x ) + (2 x ) = = 2 windows WindowBranch CircuitBreakers (max 40A)Space RequiredFor Each with EPDor1-pole with signal + Neutral with signal contactor2-pole with signal with EPDor3-pole with signal 2: Disconnect SwitchIf a disconnect switch is required, select suffix from Switch Disconnect3-phaseSingle Phase40 3S* 40 2S* 4080 3S* 80 2S* 80125 3S* 125 2S* 125180 3S 180 *Add F if fuses required. Fuses supplied by others. See page US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelCl. I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Step 3: Panel SizeDetermine Panel Size Based on Windows RequiredNumber of WindowsRequiredType Required Disconnect1, 2A mini panel40A disconnect Integral3B panelOptional Adjacent4 6C panelOptional Adjacent7 9D panelOptional AdjacentType A Mini Panels with Main Switch40A 3-Phase40A Fused 3-PhaseQuantity ofSingle CircuitsD2Z A306 - 3S40*D2Z A306 - 3SF40*6D2Z A308 - 3S40*8D2Z A310 - 3S40*10D2Z A312 - 3S40*12 Single PhaseSingle PhaseQuantity ofSingle CircuitsD2Z A106 - 2S40*D2Z A106 - 2SF40*6D2Z A108 - 2S40*8D2Z A110 - 2S40*10D2Z A112 - 2S40*12*See page 661 to complete catalog Type B, C, and US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelCl.

9 I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Step 4: Conduit/Cable EntriesDetermine if additional entries are required on sides B and C. All panels are supplied with bottom entries (Side A), 1 main supply andremainder as : Size D panels with disconnect switch have 1 main supply and 3 branch plates as EntriesTypeEntriesLocationMain Supply(1) 2" + (3) 1"A (Standard)Branches(9) 3/4" (B panel)A (Standard)(18) 3/4" (C panel)A (Standard)(27) 3/4" (D panel)A (Standard)Branches(9) 3/4"B (Optional) left side(9) 3/4"C (Optional) left sideTerminal WiringSupply CircuitsBranch CircuitsAmperagemm2 AWGA mperagemm2 AWG40166-1810412-2280352-615412-22125708 -2/020106-14180956-3 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelCl.

10 I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 How to Build a Catalog Number US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds Business1AD2Z PanelboardsZone 1, Division 2 Non-metallic or Stainless SteelCl. I, Div. 2, Groups A, B, C, DCl. I, zone 1 , Group IICCl. II, Div. 1, Groups E, F, GAEx de II C T4, T6Ex de IIC T4, T6 NEMA 4X, IP65 Spare Component InformationLighting Circuits Order Code10k AIC, max. 480 VAC1-pole6/windowSIA 0012-pole4/windowSIA 0023-pole3/windowSIA 0034-pole2/windowSIA 004 Heat-Tracing Order CodeEPD with 10k AIC, 30mA leakage, max. 480 VAC1-pole + N4/windowFSS 0022-pole2/windowFSS 004 Please state rated current on order:2, 6, 10, 16, 20, 25, 32 or 40A.*Optional:Auxiliary contact SAH 001 Signal contact SAS 001 (in the case ofbranch breakers withsignal contacts, the nextlargest component size isused)Example:SIA 001-20 SAH001 Single Pole, 20A with auxiliary contactsPlease state rated current on order:6, 10, 16, 20, 25, 32 or :With auxiliary contact FSH 001 With signal contact in Size 4 component FSS001 Example:FSS 004 - 30 FSS001 EPD, 30A, 30mA with signal contact*25 ampere max.