Example: confidence

1P Arktite Heavy Duty Circuit Breaking Plugs and …

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds Business1 PArktite Heavy duty CircuitBreaking Plugs and ReceptaclesIndustrial Heavy DutyNon-hazardous AreasNEMA 4 WatertightApplications:Arktitecircuit Breaking Plugs andreceptacles are used: To supply power to portable electricallyoperated devices such as motor-generator sets, compressors, heatingand cooling units, welders, conveyors,lighting systems and similar equipment Where temporary power is needed, suchas at trailers, building units, heavymachinery and similar equipment Wherever electrical loads must bequickly disconnected from power source In a typical installation, where a largemachine utilizes a number of electricalmotor drives and for ease of adjustment,removal, maintenance and replacement.

1P 1312 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business 1P Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles

Tags:

  Course, Heavy, Duty, Plugs, Circuit, Breaking, Hinds, Arktite, Arktite heavy duty circuit breaking plugs and, Heavy duty circuit breaking plugs and

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 1P Arktite Heavy Duty Circuit Breaking Plugs and …

1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds Business1 PArktite Heavy duty CircuitBreaking Plugs and ReceptaclesIndustrial Heavy DutyNon-hazardous AreasNEMA 4 WatertightApplications:Arktitecircuit Breaking Plugs andreceptacles are used: To supply power to portable electricallyoperated devices such as motor-generator sets, compressors, heatingand cooling units, welders, conveyors,lighting systems and similar equipment Where temporary power is needed, suchas at trailers, building units, heavymachinery and similar equipment Wherever electrical loads must bequickly disconnected from power source In a typical installation, where a largemachine utilizes a number of electricalmotor drives and for ease of adjustment,removal, maintenance and replacement.

2 Each motor is connected by portablecord and Arktitereceptacles rather thanpermanently wired In areas where dust, dirt, moisture andcorrosion are a problem Indoors and outdoors in non-hazardousareas of chemical plants, processindustry facilities, meat packing plants,manufacturing plants and similarindustrial locationsFeatures: Circuit Breaking : Plugs through 100ampere rating may be disconnectedunder load; 150-400 ampere units arefor service disconnect use only. Receptacles accept only Plugs of thesame amperage rating, style andnumber of poles, making it impossible to mismate, and provides for positivepolarization.

3 Extra wide electrical spacing allows formaximum safety. Insulator materials are the result ofintensive testing. Selection has beenmade based on highest dielectricstrength, maximum mechanical andimpact resistance, lowest moistureabsorption and highest arc trackingresistance. A variety of installations is possible dueto the availability of several types ofback boxes. Designed to withstand rough usage andthe effects of adverse environments. Reversible interiors, 30, 60 and 100ampere (except 30 and 60 ampere, 5-pole) Arktiteplug and receptacleinteriors are interchangeable using ascrewdriver.

4 This makes it possible tofeed a normally de-energized receptaclefrom an energized plug with usual Arktitesafety; no energized contacts areexposed.* APJ and NPJ Plugs only** Excludes 200A and 400A APR ConnectorsCertifications andCompliances: UL Standards: 1203*; 1682, 1686 CSA Standard: No. CE (LVD) 2006/95/EEC** US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds Business1 PArktite Heavy duty CircuitBreaking Plugs and ReceptaclesIndustrial Heavy DutyNon-hazardous AreasNEMA 4 WatertightSplit Pin Contact Design: Provides nearly 360 of contact atevery insertion, ensuring protectionagainst heat rise and eliminatingarcing on critical surfaces Continuous contact over lengthand circumference of mated pinsprovides superior safety and long-term performance Self-wiping at every insertion toprevent environmentalcontamination build-up The additional features below are called out in the illustration on this pageThe ground contact is bonded to thereceptacle housing (Style 2)

5 Unimpeded, easy-access phase and groundterminals make wire termination quick and easyGrounding contacts that make-first and break-last in the unlikely event of keyway failureAn arc formed when the plug is beingremoved is instantly snuffed in the deepconfined insulated arcing chamberA detent spring forms a parallel groundingpath through the metallic plug sleeve andreceptacle housing and is the first contact tomake and the last to breakThe plug sleeve is keyed to the receptacle toprevent mispolarizationThe gasketing system providesunsurpassed watertight integrity (NEMA 4)

6 All aluminum Uni-Shell constructionprovides superior strength in abusiveenvironmentsThe Tri-Lock cable grip has 3-piece designthat equally distributes gripping power aroundperimeter of cable. Cord jacket does not getpinched, eliminating potential for damage toboth internal conductors and external cablejacket. Cable grip is located inside plughousing, eliminating corrosion of vitalhardware and making plug maintenance unique Sure-Seal cable gland has twogasket sizes which fit entire range of cablediameters, reducing risk of improperassembly. The gasket ratchets into the Tri-lock cable grip to prevent plug fromturning or loosening in high vibration surfaces make Arktite plugsquick and easy to assembleSmooth and contoured design of plughousing eliminates occurrence of cable gripsnagging or Breaking off.

7 Tri-Lock screwsare captive so cable grip cannot come apartduring assembly. Prevents critical screwsfrom getting lost during sleeve between insulator body andhousing minimizes possibility of electricalshock in event of ground failure. Increasescreepage and clearance Advantage Features:Internal Plug Safety Insulator Plastic barrier between insulator body andmetal housing minimizes risk of energizinghandle body due to stray conductor strands Increases creepage and clearance protectionCE Marked Offers a borderless solution with no additionalinspection or documentation required forapprovalLockout Plug Allows users to comply with OSHA lockout/tagout requirements Ensures plug cannot be inserted intoreceptacle when maintenance is beingperformed downstream of power supplyTri-Lock Cable Grip Three-piece design equally distributes

8 Griparound perimeter of cable Cable jacket does not get pinched, eliminatingpotential for damage to internal conductors Captive screws allow maximum extension ofcord grip without risk of loose componentsSure-Seal Cable Gland Two gasket sizes fit entire cable range,reducing risk of improper assembly Gasket ratches into Tri-Lock cable grip toprovide environmental protection in highvibration areasPlug Housing Smooth design eliminates occurrence of cablegrip snagging or Breaking off Houses Tri-Lock cable grip to eliminatecorrosion of vital hardware and increase ease ofmaintenanceCombination Drive Stainless Steel Hardware Increases ease of installation by allowing formore than one option for installation tools Stainless steel external hardware eliminatescorrosion on critical components and extendsproduct

9 LifeInsulator Assemblies Unimpeded, easy access phase and groundterminals make wire termination quick and easy Lug screws secured with tape to prevent themfrom vibrating loose and falling out duringshippingCombination Slot and Hex Mechanical Lugs* Increases ease of installation by allowing formore than one option for installation tools Hex head allows for easy achievement ofspecified torque valueReceptacle Cover Automatic weatherproof seal every time plug isdisengaged Field replaceable design allows for new coverto be threaded on quickly and easily*60, 100, and 150A US.

10 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse- hinds Business1 PArktite Heavy duty CircuitBreaking Plugs and ReceptaclesNEMA 4 WatertightGrounding: Style 1 vs. Style 2 Eaton's Crouse- hinds Arktite devices utilize two methods, or styles, for completing the grounding Circuit in Plugs and receptacles. NECreference (A) & (B).Style 1 MetallicA Style 1 plug is one in which thegrounding conductor in the flexible cable isbonded to the plug sleeve by a pressureconnector. A Style 1 receptacle is onewhich is grounded by virtue of the fact thatit is an integral part of a grounded conduitsystem.