Example: air traffic controller

2008 Standard for - Air Conditioning, Heating and ...

ANSI/AHRI Standard 210/240 with Addenda 1 and 2. (formerly ARI Standard 210/240). 2008 Standard for Performance Rating of Unitary Air- conditioning & Air-Source Heat Pump Equipment Approved by ANSI in December 2012. ANSI/AHRI Standard 210/240- 2008 WITH. ADDENDUM 2. Performance Rating of Unitary Air- conditioning &. Air-Source Heat Pump Equipment March 2012. Addendum 2 of ANSI/AHRI Standard 210/240- 2008 , is provided as follows. The following changes have been incorporated (additions are shown with highlights; deletions are shown by strikethroughs) into the already published 2008 version of ANSI/AHRI Standard 210/240 with Addendum 1 to avoid confusion: The Integrated Energy Efficiency Ratio (IEER) methodology has been added to the Standard for water-cooled and evaporatively-cooled products.

ANSI/AHRI STANDARD 210/240-2008 WITH ADDENDUM 2 . Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment . March 2012 . Addendum 2 of ANSI/AHRI Standard 210/2402008, is provided as follows.

Tags:

  Standards, Conditioning, 2008, Air conditioning, 2008 standard for

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2008 Standard for - Air Conditioning, Heating and ...

1 ANSI/AHRI Standard 210/240 with Addenda 1 and 2. (formerly ARI Standard 210/240). 2008 Standard for Performance Rating of Unitary Air- conditioning & Air-Source Heat Pump Equipment Approved by ANSI in December 2012. ANSI/AHRI Standard 210/240- 2008 WITH. ADDENDUM 2. Performance Rating of Unitary Air- conditioning &. Air-Source Heat Pump Equipment March 2012. Addendum 2 of ANSI/AHRI Standard 210/240- 2008 , is provided as follows. The following changes have been incorporated (additions are shown with highlights; deletions are shown by strikethroughs) into the already published 2008 version of ANSI/AHRI Standard 210/240 with Addendum 1 to avoid confusion: The Integrated Energy Efficiency Ratio (IEER) methodology has been added to the Standard for water-cooled and evaporatively-cooled products.

2 It is not intended for air-cooled products which should be rated with SEER. This includes: 1. The addition of definition of IEER (page 2). 2. The addition of and in multiples of for IEER to Section (page 5). 3. The addition of Part-Load IEER Conditions to Test Conditions to Table 12 (page 21). 4. The reinstatement of Note 2 in Table 12 (page 21). 5. New Section Part Load Ratings (pages 22-26). This new Section is duplicated from Section from AHRI Standard 340/360-2007 with addenda 1 and 2. 6. The addition of plus the IEER (where applicable), to Section (page 26). 7. The addition of except IEER which shall not be less than 90% of Published Ratings.

3 To Section (page 26). 8. The addition of 3. Integrated Energy Efficiency Ratio, IEER , to Section (page 27). ANSI/AHRI Standard 210/240- 2008 WITH. ADDENDUM 1. Performance Rating of Unitary Air- conditioning &. Air-Source Heat Pump Equipment June 2011. Addendum 1 of ANSI/AHRI Standard 210/240- 2008 , is provided as follows. The following changes have been incorporated (deletions are shown by strikethroughs) into the already published 2008 version of ANSI/AHRI. Standard 210/240 to avoid confusion: The Integrated Part-Load Values (IPLV) methodology has been removed from the Standard . This includes the deletion of: 9.

4 Section Integrated Part Load Value (IPLV) Definition (page 2). 10. and in multiples of for IPLV from Section (page 5). 11. The Part Load Conditions line and Note 2 of Table 12 (page 21). 12. Section Part Load Ratings (pages 21-22). 13. plus the IPLV (where applicable) from Section (page 22). 14. Appendix E. The corresponding Table E1 has also been removed (pages 122-125). IMPORTANT. SAFETY DISCLAIMER. AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this Standard /guideline.

5 It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this Standard /guideline. AHRI uses its best efforts to develop standards /guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards /guidelines will be non-hazardous or free from risk. AHRI CERTIFICATION PROGRAM PROVISIONS. Scope of the Certification Program The Certification Program includes all Unitary Air- conditioning and Air-Source Unitary Heat Pump equipment rated below 65,000 Btu/h [19,000 W] at AHRI Standard Rating Conditions (Cooling).

6 Certified Ratings The following Certification Program ratings are verified by test: Unitary Air-Conditioners A. Air-cooled under 65,000 Btu/h [19,000 W]. 1. AHRI Standard Rating Cooling Capacity, Btu/h [W]. 2. Seasonal Energy Efficiency Ratio, SEER, Btu/(W h). B. Water-cooled and evaporatively-cooled under 65,000 Btu/h [19,000 W]. 1. AHRI Standard Rating Cooling Capacity, Btu/h [W]. 2. Energy Efficiency Ratio, EER, Btu/(W h). 3. Integrated Energy Efficiency Ratio, IEER, Btu/(W h). Air-Source Unitary Heat Pumps Air-cooled under 65,000 Btu/h [19,000 W]. 1. AHRI Standard Rating Cooling Capacity, Btu/h [W].

7 2. Seasonal Energy Efficiency Ratio, SEER, Btu/(W h). 3. High Temperature Heating Standard Rating Capacity, Btu/h [W]. 4. Region IV Heating Seasonal Performance Factor, HSPF, Minimum Design Heating Requirement, Btu/(W h). Conformance to the requirements of the Maximum Operating Conditions Test, Voltage Tolerance Test, Low- Temperature Operation Test (Cooling), Insulation Effectiveness Test (Cooling), and Condensate Disposal Test (Cooling), as outlined in Section 8, are also verified by test. Note: This Standard supersedes ARI Standard 210/240-2006. TABLE OF CONTENTS. SECTION PAGE. Section 1. 1. Section 2.

8 Scope .. 1. Section 3. 1. Section 4. Classifications .. 4. Section 5. Test Requirements .. 4. Section 6. Rating Requirements .. 4. Section 7. Minimum Data Requirements for Published Ratings .. 27. Section 8. Operating Requirements .. 27. Section 9. Marking and Nameplate Data .. 30. Section 10. Conformance Conditions ..30. TABLES. Table 1. Classification of Unitary Air-Conditioners .. 6. Table 2. Classification of Air-Source Unitary Heat Pumps .. 7. Table 3. Cooling Mode Test Conditions for Units Having a Single-Speed Compressor and a Fixed-Speed Indoor Fan, a Constant Air Volume Rate Indoor Fan, or No Indoor Fan.

9 14. Table 4. Heating Mode Test Conditions for Units Having a Single-Speed Compressor and a Fixed-Speed Indoor Fan, a Constant Air Volume Rate Indoor Fan, or No Indoor Fan .. 14. Table 5. Cooling Mode Test Conditions for Units Having a Single-Speed Compressor and a Variable Air Volume Rate Indoor Fan that Correlates with the Outdoor Dry Bulb Temperature (Section ) .. 15. Table 6. Heating Mode Test Conditions for Units Having a Single-Speed Compressor and a Variable Air Volume Rate Indoor 16. TABLES (Cont'd). Table 7. Cooling Mode Test Conditions for Units Having a Two-Capacity Compressor .. 17. Table 8.

10 Heating Mode Test Conditions for Units Having a Two-Capacity Compressor .. 18. Table 9. Cooling Mode Test Conditions for Units Having a Variable-Speed Compressor .. 19. Table 10. Heating Mode Test Conditions for Units Having a Variable-Speed Compressor .. 20. Table 11. Minimum External Static Pressure for Ducted Systems Tested with an Indoor Fan Installed .. 20. Table 12. Conditions for Standard Rating Tests and Operating Requirement Tests for Water-cooled and Evaporatively-cooled Equipment Using ASHRAE. Standard 37 .. 21. Table 12A. IEER Part-Load Rating Conditions .. 23. Table 13. Conditions for Operating Requirement Tests for Air-cooled Equipment.


Related search queries