Compact, attractive, and easy to install, the System Sensor 2012HA detec-tor is designed to respond to a broad range of fires while providing maximum stability. This model also features low-voltage wiring making it ideal for applica-tions such as apartment buildings and nursing System Sensor 2012HA photoelectronic Detector is designed primarily for applications where low-voltage Class 2 wiring may be used. This detec-tor is non-latching and offers an 85dB alarm horn. The 2012HA features an audible emergency evacuation signal referred to as temporal (3) tone. An external push button provides a test of the Detector s alarm function. Up to 12 units can be interconnected so that if one Detector alarms, all detectors alarm. A normally open auxiliary alarm Relay with an 8 second delay is available for controlling external functions. A visible LED indicator flashes once every 30 seconds in standby and rapidly (every seconds) in alarm when detecting Smoke .

Operating Voltage 12 VDC (nominal) Relay Contact Rating 1 Form A, .5 A @ 30 VDC Standby Current 60 µA maximum average Alarm Current 20 mA maximum average @ 12 VDC

Tags:

  Smoke, Smoke detector

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2012HA Direct-Wire Smoke Detector with Built-in Relay and …

1 Compact, attractive, and easy to install, the System Sensor 2012HA detec-tor is designed to respond to a broad range of fires while providing maximum stability. This model also features low-voltage wiring making it ideal for applica-tions such as apartment buildings and nursing System Sensor 2012HA photoelectronic Detector is designed primarily for applications where low-voltage Class 2 wiring may be used. This detec-tor is non-latching and offers an 85dB alarm horn. The 2012HA features an audible emergency evacuation signal referred to as temporal (3) tone. An external push button provides a test of the Detector s alarm function. Up to 12 units can be interconnected so that if one Detector alarms, all detectors alarm. A normally open auxiliary alarm Relay with an 8 second delay is available for controlling external functions. A visible LED indicator flashes once every 30 seconds in standby and rapidly (every seconds) in alarm when detecting Smoke .

2 The Detector offers low-voltage operation and a tamper-proof feature. Screw terminals and a mounting bracket are provided for easy VDC operation, 4-wireBuilt-in 85dB electronic horn with temporal (3) toneBuilt-in, normally open Relay can be connected to lights, bells, horns, or remote annunciatorInterconnectable up to 12 unitsVisual alarm and power indicatorCeiling white colorBuilt-in 8 second delay on Relay outputBuilt-in test switchTwist-on mounting bracket with tamper option for easy installationRugged chamber design for greater stability3-year warrantyAvailable Models2012HA - Photoelectronic DetectorFeatures2012HA Photoelectronic Smoke Detector2012HA Direct-Wire Smoke Detector with Built-in Relay and Horn 1999 System Sensor Canada. CAN - A05-238-03 Operating Voltage12 VDC (nominal) Relay Contact Rating1 Form A, .5 A @ 30 VDCS tandby Current60 A maximum averageAlarm Current20 mA maximum average @ 12 VDCT emperature Range32 to 120 F (0 to 50 C) CAN - A05-238-03 Ordering InformationPart Number Description2012HA Photoelectronic Smoke Detector with Relay , 12 VDC, multiple stationA77-727-01 12 VDC power supply, mounts to a 4 square box, 2 1/8 H x dia.

3 ( mm h x 140 mm dia.) oz. (150 grams)Humidity Range10% to 93% RH, noncondensingGeneral SpecificationsElectrical Ratings2012HA Wiring DiagramULC LISTED RESIDENTIAL FIRE/SECURITY PANEL12 VDCA uxiliary Alarm Relay For Security Panel Monitoring ( )Maximum power bus length (in feet), given number of units (maximum per bus) and wire Gauge 14 AWG 16 AWG 18 AWG1 Unit 5000 3735 23492 Units 2970 1867 11743 Units 1980 1245 7834 Units 1485 933 5875 Units 1188 747 4696 Units 990 622 3917 Units 848 533 3358 Units 742 466 2939 Units 660 415 26110 Units 594 373 23411 Units 540 339 21312 Units 495 311 195 Maximum interconnect bus length: 5,000 FT., No. 18 AWG or larger dual conductor wiring must conform to local electrical Smoke Detector PlacementAs defined in NFPA72 Smoke detectors shall be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements and excluding crawlspaces and unfinished attics.

4 In new construction, a Smoke Detector shall also be installed in each sleeping room . Refer to local building and fire codes for required installation locations for Smoke detectors. Installation shall be in accordance with CAN/ULC-S524. Inspection shall be in accordance with Sensor Canada6581 Kitimat Rd. Unit # 6 Mississauga, ON L5N 3T5Ph: 800-SENSOR2 Fx: 905-812-0771 Sensor Headquarters USAPh: 630-377-6674 Fx: 630-377-6495 System Sensor in EuropePh: Fx: Sensor in ChinaPh: Fx: Sensor in SingaporePh: Fx: Sensor Far EastPh: Fx: Sensor Latin AmericaPh: Fx: 2005 System Sensor. The company reserves the right to change product specifications without notice. System Sensor Sales and Servic