Example: tourism industry

23546-I FOAMULAR Thermapink XPS DS

FOAMULAR Thermapink . Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet efficiencies during installation and covers all ASTM C578. such as direct-to-steel deck properties with no gypsum board thermal GREENGUARD Gold Certified barrier needed in most commercial single-ply and metal The only XPS foam with roofing systems. FOAMULAR certified recycled content . Thermapink Extruded certified by SCS Global Services Polystyrene (XPS) Rigid Foam to contain a minimum 20%. Insulation can be placed over a recycled content concrete deck or directly on a Will not corrode, rot or Energy-Saving1, Moisture- non-fire-resistance-rated (non support mold growth Resistant XPS Insulation ASTM E119 hourly rated) steel Zero ozone depletion potential Direct-to-Deck Roofing roof deck without the need with 70% less global warming Insulation for a thermal barrier board.

Additional protection over the THERMAPINK® Extruded Polystyrene (XPS) Rigid Foam Insulation such as added cover boards, refl ective membrane surfaces or pavers may be

Tags:

  Foamular, Thermapink, Foamular thermapink xps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 23546-I FOAMULAR Thermapink XPS DS

1 FOAMULAR Thermapink . Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet efficiencies during installation and covers all ASTM C578. such as direct-to-steel deck properties with no gypsum board thermal GREENGUARD Gold Certified barrier needed in most commercial single-ply and metal The only XPS foam with roofing systems. FOAMULAR certified recycled content . Thermapink Extruded certified by SCS Global Services Polystyrene (XPS) Rigid Foam to contain a minimum 20%. Insulation can be placed over a recycled content concrete deck or directly on a Will not corrode, rot or Energy-Saving1, Moisture- non-fire-resistance-rated (non support mold growth Resistant XPS Insulation ASTM E119 hourly rated) steel Zero ozone depletion potential Direct-to-Deck Roofing roof deck without the need with 70% less global warming Insulation for a thermal barrier board.

2 Potential than our previous For additional details, see formula Thermapink 18 Insulation: Underwriters Laboratories (UL). ASTM C578 Type X, 18 psi Inc. Roof Deck Construction Reusable minimum #457, tested in accordance Lightweight, durable rigid Thermapink 25 Insulation: with ANSI/UL Standard 1256. foam panels are easy to handle ASTM C578 Type IV, 25 psi This application requires that and install minimum the insulation be capable of Easy to saw, cut or score Description spanning across rib openings in Owens Corning FOAMULAR the deck and provide reasonable Technical Information Thermapink Extruded resistance to foot traffic and FOAMULAR Thermapink . Polystyrene (XPS) Insulation is other normal roof loads.

3 See Extruded Polystyrene (XPS). a closed cell, moisture-resistant the Flute Span Capability chart Rigid Foam Insulation is a rigid foam board specially for recommended minimum thermoplastic material with a designed for roofing applications. FOAMULAR Thermapink maximum service temperature of Extruded Polystyrene (XPS) 165 F. In horizontal applications, Like all FOAMULAR Rigid Foam Insulation thicknesses FOAMULAR XPS Insulation XPS Insulation products, applied direct to deck. may experience greater solar FOAMULAR Thermapink exposure than in vertical Extruded Polystyrene (XPS) Key Features applications and it may be Rigid Foam Insulation is made Exceptional moisture resistance damaged by heat buildup.

4 Simple with Owens Corning's patented and outstanding insulation for precautions during construction Hydrovac process technology direct-to-deck application in can minimize the potential for under strict quality control steel deck roofing systems heat related damage. Install only measures, which helps to make it Excellent long-term stable as much FOAMULAR XPS. highly resistant to moisture and insulating performance with an Insulation as can be covered in permits the product to retain its R-value2 of R-5 per inch the same day. For horizontal high R-value year after year even applications always turn the print after exposure to moisture. Exceptional moisture resistance, side down so the black print does long-term durability not show to the sun which may, FOAMULAR Thermapink Limited lifetime warranty3 at times, act as a solar collector Extruded Polystyrene (XPS) maintains 90% of R-value and raise the temperature of Rigid Foam Insulation provides the foam surface under the 1 Savings vary.

5 Find out why in the seller's fact sheet 2 R means the resistance to heat flow; the higher the R-value, the greater the insulating power. print. Additional protection over on R-values. Higher R-values mean greater insulating 3 See actual warranty for complete details, limitations FOAMULAR XPS Insulation power. and requirements. FOAMULAR Thermapink . Extruded Polystyrene (XPS) Rigid Foam Insulation Product Data Sheet such as added cover boards, Typical Physical Properties1. reflective membrane surfaces, FOAMULAR Thermapink Extruded Polystyrene (XPS) Rigid Foam Insulation or pavers may be required in Thermapink Insulation areas adjacent to reflective walls, Property Test Method 2. 18 25. parapets, rooftop equipment Thermal Resistance3, R-Value (180 day) minimum, ASTM C518.

6 Hr ft 2 F/Btu (RSI, C m2/W). areas or other vertical surfaces @ 75 F (24 C) mean temperature that may reflect and intensify 1 Thickness ( ). 1 Thickness ( ). the sun's energy. Do not cover 2 Thickness 10 ( ). FOAMULAR XPS Insulation 3 Thickness 15 ( ). 4 Thickness 20 ( ). either stored (factory wrapped or @ 40 F ( C) mean temperature unwrapped), or partially installed, 1 Thickness ( ). 1 Thickness ( ). with dark colored (non-white), 2 Thickness ( ). or clear (non-opaque) coverings 3 Thickness ( ). and leave it exposed to the 4 Thickness ( ). Long Term Thermal Resistance, LTTR-Value3, minimum sun. Examples of such coverings F ft 2 hr/Btu (RSI, C m2/W). include but are not limited @ 75 F (24 C) mean temperature CAN/ULC S770-03.

7 1" Thickness ( ). to filter fabrics, membranes, 1 " Thickness ( ). temporary tarps, clear 2" Thickness ( ). 3" Thickness ( ). polyethylene, etc. If improperly 4" Thickness ( ). covered, and exposed to the Compressive Strength4, minimum psi (kPa) ASTM D1621 18 (124) 25 (172). right combination of sun, time Flexural Strength5, minimum psi (kPa) ASTM C203 60 (414) 75 (517). and temperature, deformation Water Absorption 6, maximum % by volume ASTM C272 damage may occur rapidly. When Water Vapor Permeance7, maximum perm (ng/Pa s m2) ASTM E96 (86). covering is necessary, use only Dimensional Stability, maximum % linear change ASTM D2126 white opaque material, or, cover Flame Spread 8, 9 ASTM E84 5.

8 Smoke Developed 8, 9, 10 ASTM E84 45-175. with the final approved finish Oxygen Index8, minimum % by volume ASTM D2863 24. material as soon as possible. Service Temperature, maximum F ( C) 165 (74). A white opaque cover reflects Linear Coefficient of Thermal Expansion, ASTM E228 x 10 -5 ( x 10 -5). energy from the sun rather in/in/ F (m/m/ C). than absorbing it or passing it 1. Properties shown are representative values for 1" thick material, unless otherwise specified. 2. Modified as required to meet ASTM C578. which reduces the potential for 3. R means the resistance to heat flow; the higher the value, the greater the insulation power. This insulation must be excessive heat exposure. Clear installed properly to get the marked R-value.

9 Follow the manufacturer's instructions carefully. If a manufacturer's fact sheet is not provided with the material shipment, request this and review it carefully. R-values vary depending (non-opaque) coverings allow on many factors including the mean temperature at which the test is conducted, and the age of the sample at the time of testing. Because rigid foam plastic insulation products are not all aged in accordance with the same light energy from the sun to standards, it is useful to publish comparison R-value data. The R-value for FOAMULAR XPS Insulation is provided pass through rather than reflect from testing at two mean temperatures, 40 F and 75 F, and from two aging (conditioning) techniques, 180 day real- time aged (as mandated by ASTM C578) and a method of accelerated aging sometimes called Long Term Thermal it which may produce a partial Resistance (LTTR) per CAN/ULC S770-03.

10 The R-value at 180 day real-time age and 75 F mean temperature is commonly used to compare products and is the value printed on the product. greenhouse effect, trapping hot 4. Values at yield or 10% deflection, whichever occurs first. air and raising the temperature 5. Value at yield or 5%, whichever occurs first. 6. Data ranges from to value shown due to the level of precision of the test method. below the cover. See 7. Water vapor permeance decreases as thickness increases. Owens Corning publication 8. These laboratory tests are not intended to describe the hazards presented by this material under actual fire conditions. 9. Data from Underwriters Laboratories Inc. classified. See Classification Certificate U-197.