New:Motor versions with energy - saving motors IE2 - High Efficiency orIE3 - Premium Efficiency(classification to EN 60034 - 30 based on EC Directive 640/2009 forstandardised motors)Automation products available: PumpExpert Hyamaster hyatronic LevelControl Basic 2 AmarexKRTType series 9--ENOther versions on requestSubmersible motor pumps DN 40 to DN 700 Stationary installationTransportable installationDry-installedCast iron and various materials for industrial effluents50 Hzstandard rangeApplicationsAmarex submersible motor pumps are used for pumping alltypes of sewage and effluent in water treatment and industry,especially untreated sewage with long fibrous and solidsubstances, liquids containing air and gas as well as raw,activated and digested dataCapacityQ up to 10 000 m3/h.

Amarex KRT 2 Contents Page Product advantages 3 Impeller Types 4 Guide to material and hydraulics selection for individual pumped liquids 5 Selection Diagrams 50 Hz 6--9

Tags:

  Amarex

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2553.5/ 9--EN Amarex - tulumbapompa.com.tr

1 New:Motor versions with energy - saving motors IE2 - High Efficiency orIE3 - Premium Efficiency(classification to EN 60034 - 30 based on EC Directive 640/2009 forstandardised motors)Automation products available: PumpExpert Hyamaster hyatronic LevelControl Basic 2 AmarexKRTType series 9--ENOther versions on requestSubmersible motor pumps DN 40 to DN 700 Stationary installationTransportable installationDry-installedCast iron and various materials for industrial effluents50 Hzstandard rangeApplicationsAmarex submersible motor pumps are used for pumping alltypes of sewage and effluent in water treatment and industry,especially untreated sewage with long fibrous and solidsubstances, liquids containing air and gas as well as raw,activated and digested dataCapacityQ up to 10 000 m3/h.

2 2 778 l/sHeadHup to 100 mMotor powerP2from kW to 850 kWTemperature ofpumped liquidtup to 60oCEnclosure type IP 68 to IEC 60034--5additional flameproof versions ATEX II 2G T3 or T4 DriveThree-phase asynchronous motor400 V(variants: 230 V, 380 V, 415 V, 500 V, 690 V)MaterialStandard version of cast ironMaterialvariantsofwear-resistantchil ledironandcorrosion-resistant duplex stainless steelShaft sealing2 mechanical seals beingindependent of the direction ofrotation, lubricated with non-toxic oilBearingsgrease lubricated ball bearingsDesignationExampleImpeller typeS, F, E, D, KPump typeHydraulics dimensionMotor sizeNumber of polesMotor versionU, UN, UK, W, WN, X, XN, XK, Y, YNMaterial version / variantG, G1, G2, GH, H, C1, C2 Installation TypeS, P, K, D, HKRT K 150-500/80 4 UN G -- DAmarexKRT2 ContentsPageProduct advantages3 Impeller Types4 Guide to material and hydraulics selection for individual pumped liquids5 Selection Diagrams 50 Hz6--9 Guarantee.

3 Tests / Inspections and Quality Assurance9 Technical Data10--12 Installation Types13 Materials14 TECHNICAL DATA -- STANDARD PROGRAMME / (standard variants)15--16 Typical sectional drawing17--18 Shaft Seal19 AmarexKRT3 Product advantagesExample: Amarex KRT K 100-250/7 4 WGEKA bsolutely water--tightEven in the event of power cabledamage, no fluid can penetrateinto the service life2 bi--rotational mechanical sealsVariable hydraulic systemThe right impeller with optimumefficiency for every operating reliability due towide free specially developed forsubmersible motor pumps offermaximum operating TypesS, F, E, D, KKRT K 150-315 / 12 6 U G -- SSImpeller with cutting deviceDOpen single vane impellerS-Impellerfor handling domestic sewage with coarseand / or long fibrous matterFdomestic sewageFdirty waterFfaecesD-Impellerfor sewage containing solidsubstances.

4 Long fibres and coarse sewageFmixed waterFraw and digested sludgeFactivated sludgeFcirculated and heated sludgeFVortex impellerKClosed non-clogging 2 or 3 canalimpellerF-Impelleror liquids containing long fibres, solidsubstances, coarse dirt as well as gasor sewageFactivated sludgeFcirculated and heated sludgeFraw and digested sludgeFmixed waterK-Impellerfor contaminated liquids containingsludges and solids which arenon-gaseous and not containing fibresliable to twist or sewageFmechanically treated sewageFindustrial waste waterFeffluent from waste disposal sitesFstorm waterFactivated sludgeFindustrial effluentESingle vane impeller!!Hydraulic systems with S-,D-,F- and E-impellersE-Impellerfor sewage containing long fibres andsolid sewageFmixed waterFraw and digested sludgeFactivated sludgeFcirculated and heated sludge!

5 !HydraulicsystemswithS-,D-,F-andE-impell ersare available only as shown in the documentedQH can be adjusted to the required to material and hydraulics selection for individual pumped liquidsThe table below is intended as a guide for selecting pump materials and hydraulics and is based onmany years of KSB data given in the table is intended as a recommendation / guide only. For more detailed information, please consult yournearest KSB sales office or ask for expert advice from theKSB advisory departments. Take advantage of the extensive KSBlaboratory know-how when selecting pump liquidSuggestedimpeller typeComments and recommendationsDirty waterRiver waterK, D, E, Ffree passage >solids in pumped liquid, possibly pre-screenedStorm waterpgppqpypWaste water-- untreated municipal sewageF, S, D, E, KATV recommendation: free passage of 100 mm,min76mm(3 )-- containing gas and airFup to 8 %, consult KSB when pumpinghighly gaseous raw sludgeF,D,Ecanbepumpedwithasolidscontent :-- digested sludgeF,D,Ecan be pumped with a solids content :13 %(D),8%(F),6%(E),5%(K)-- activated sludgeD,K13%(D),8%(F),6%(E),5%(K)Industr ial effluent contaminated with.

6 -- paint suspensionKsolvent-free; refer to operator instruction-- varnish suspensionF, Esolvent-free;consult KSBfor silicone-free versionn-- fibrous substancesF, S , Dron-- filings / chippingsK, FG2 or GH variant, special mechanical sealstIr-- abrasive substancesK, FG2orGHvariant,specialmechanicalsealSoli ds content <5 g/lastIndustrial effluent, slightly acidK, Fph-value < C1 variant and FPM (Viton) O-ringsCaWaste water, chemically neutral in respect of corrosion-- ammonia waterK-- ammonia hydroxide 5 % NH4 OHK-- urea 25 % (NH2)2-COK-- potassium hydroxide 10 % KOHK-- calcium hydroxide 5 % Ca(OH)2K-- sodium hydroxide 5 % NaOHK-- sodium carbonate 30 % Na2CO3 KWaste water, chemically neutral in respect of corrosion, contaminated with ..-- aliphatic hydrocarbons, oils, petrol, butane, methaneK-- aromatic hydrocarbons, benzene, styreneK-- chlorinated hydrocarbons, trichloroethylene, ethylene chloride,chloroform, methylene chlorideKFPM (Viton) O-rings, for high concentrationsconsult KSBH ighly abrasive industrial waste water (chemically neutral)

7 On-- sinter waterKA sinter content of <5 g/l requires GH designA sinter content of >5 g/l requires H designediro-- lime-milk with quartz and pigmentsuspensionKup to 15% lime-milk requires GH design>15% lime-milk requires H designhille-- wash water containing solidsK, FmaterialvariantdependsonliquidanalysisC h-- waste water containing dust / ashKmaterialvariantdependsonliquidanalys isCWater-sand mixtureK, Fup to 5 g/l solids content requires GH variant -- above 5 g/l:H variantx-Sea waterK, FC2-variantDuplexsteelBrackish waterK, FC1 or G1 (with 250mm 2-comp. epoxy resin),-- depending on salt contentDusCorrosive industrial effluentK, FC1 or C2, depending on analysis of pumped mediaAmarexKRT6 Selection Diagrams 50 [m]50--210/ 2p40--250/ 2pQ[m3/h] [m]150--315/ 6p100--401/ 4p100--315/ 4p150--401/ 6p40--250/ 2p80--250/251/ 2p40--250/ 4p80--250/ 4p100--250/ 4pQ[m3/h]80--316/ 2p100--240/ 2p150--401/ [m]100--250/ 4p100--315/ 4p150--315/ 4p100--401/ 4p150--401/ 4p150--315/ 6p200--401/ 4p150--401/ 6p200--401/ 6p80--250/ 4pQ[m3/h] [m]100--251/ 4p150--401/ 4p100--316/ 4p150--400/ 4p150--315/ 4p200--315/ 4p150--401/ 6p200--400/ 4p200--315/ 6p250--400/ 4p200--400/ 6p300--400/ 6p250--400/ 6p80--315/ 2p100--315/ 2p80--315/ 4pQ[m3/h]150--251/ 4p150--315/ [m]

8 100--315/ 4p40--250/ 2p100--250/ 4p80--251/ 2p50--210/ 4p50--210/ 2p40--250/ 4pQ[m3/h]100--400/ 4p100--401/ [m]150--315/ 6p150--315/ 4p150--401/ 4p200--315/ 6p200--401/ 6p200--316/ 6p151--401/4p/4p200--330/ 4p250--400/ 6p250--400/ 4p300--400/ 8p250--630/ 6p200--500/ 4p150--500/ 4p300--400/ 6pQ[m3/h]300--503/ 4p300--420/ 4p200--401250--401/ 4p300--500/ 6p300--401/ [m]350--420/ 6p350--500/ 6p/8p350--630/ 6p350--501/ 6p350--710/ 6p400--500/ 6p400--500/ 10p500--630/ 6p500--630/ 10p600--710/ 10p600--520/ 8p700--900/ 10p700--900/ 12pQ[m3/h]400--630/ 6p400--500/ 8p500--630/ 8p700--901/ 8p350--636/ 6p350--500 Guarantee, Tests / Inspections and Quality AssuranceEach pump is subjected to a functional test to KSB standard ZN 56 525. Pump performance is guaranteed to ISO 9906 inspections conforming to ISO / DIN or another comparable standard are possible at a quality is assured under a tested and to DIN EN ISO 9001 certified quality assurance DataCast iron (G, G1, G2, GH)Pump sizesMaterialvariantsImpellerDry installation(Installation Type D , H )Wet--well installation(Installation Type S , P , K )Moment ) ) ),3)qty.

9 [mm][mm][mm][bar][bar][bar][bar][kgm2]S 40 40 250G, G1, G2, 80 250,,, 80 80 100 240G, G1, G2, 100 250,,, 100 100 150 150 80 100 100 100 150 150 200 80--315G, 100--251, 150 200 200 250 300 40 250G, G1, 80 100 250G, G1, 100 315,, 100 100 401G, G1, 150 315,, 150 151 150 500G, 200 315G, G1, 200 316,, 200 200 200 500G, 200--501, 250 400G, G1, 250 401,, 250--630G, 300 400G, G1, 300 401,, )zul ssiger Betriebsdruck = Zulaufdruck + Druck bei Q = 02)Values for biggest impeller diameter3)Impeller with water fillAmarexKRT11 Cast iron (G, G1, G2, GH)Pump sizesMaterialvariantsImpellerDry installation(Installation Type D , H )Wet--well installation(Installation Type S , P , K )Moment ) ) ),3)qty.

10 [mm][mm][mm][bar][bar][bar][bar][kgm2]K 300 420G, 300 500, 300 350 350 350 350 350 350 500 ,0K )Allow. operating pressure = inlet pressure + pressure at Q = 02)Values for biggest impeller diameter3)Impeller with water fillIndustrial materials (H, C1, C2)Pump sizesMaterialvariantsImpellerDry installation(Installation Type D , H )Wet--well installation(Installation Type S , P , K )Moment ) ) ),3)qty.[mm][mm][mm][bar][bar][bar][bar] [kgm2]S 50 210C1, 40 250H, C1, 50 210,, 65 80 80 100 100 100 100 150 150 50--210C1, 40 250H, C1, 80 251,, 100 100 100 150 150 151 200 200 200 200 250 250 300 300 )Allow. operating pressure = inlet pressure + pressure at Q = 02)Values for biggest impeller diameter3)Impeller with water fillAmarexKRT12 Moment of inertia (Rotors)Motor sizesMoment ofinertiaMotor sizesMoment ofinertiaMotor sizesMoment ofinertiaMotor sizesMoment ofinertiaMotor sizesMoment ofinertiainertiaJinertiaJinertiaJinertia JinertiaJ[kgm2][kgm2][kgm2][kgm2][kgm2] TypesS, P, K, D, HKRT K 150-500 / 80 4 UN G -- DSStationary wet--well installation(S1 operation with motor submerged )