Example: dental hygienist

2A ER4 industrial NEMA 4X (enclosure) disconnect …

2A2 AER4 industrialdisconnect switchesUL/cULus ListedNEMA 4X (enclosure)Applications: Built to serve as a main disconnect or provide branch circuit protection in a variety of applications in heavy industrial environmentsFeatures: UL98 Listed for general purpose, main disconnect or branch circuit protection up to 600 VAC/DC Multiple field installed accessories enhance the enclosed disconnect switches to fit the desired application Lockout/tagout up to three 1/4 padlocks can be installed on external handles for added safetyElectrical ratings: Voltage 600 VAC; 250-600 VDC Amperage 16A-800A Short circuit current ratings UL98: 35kA-200kA; UL508: 10kA-65kA Operating temperature -20 C to +70 CCertifications and compliances: UL98 Listed File No.

2A 2A www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2016 Eaton Ordering information: Part number example ER4X-60J3PB AClass L fuses for 800A disconnect switch only.

Tags:

  Name, Switch, Disconnect, Disconnect switch

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2A ER4 industrial NEMA 4X (enclosure) disconnect …

1 2A2 AER4 industrialdisconnect switchesUL/cULus ListedNEMA 4X (enclosure)Applications: Built to serve as a main disconnect or provide branch circuit protection in a variety of applications in heavy industrial environmentsFeatures: UL98 Listed for general purpose, main disconnect or branch circuit protection up to 600 VAC/DC Multiple field installed accessories enhance the enclosed disconnect switches to fit the desired application Lockout/tagout up to three 1/4 padlocks can be installed on external handles for added safetyElectrical ratings: Voltage 600 VAC; 250-600 VDC Amperage 16A-800A Short circuit current ratings UL98: 35kA-200kA; UL508: 10kA-65kA Operating temperature -20 C to +70 CCertifications and compliances: UL98 Listed File No.

2 E182262, Guide WIAX, WIAX7 cULus Listed to CSA Standard , No. 14 cULus Listed to CSA Standard , No. 4 Conforms with IEC 60947-3 CE compliant RoHS compliant NEMA 4X (enclosure) Non-metallic enclosure flammability rating polycarbonate: UL 94-5VA-0; fiberglass: UL US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2016 EatonER4 industrial disconnect switches provide a robust UL98 rated design to withstand long-term corrosive and harsh complete line includes both fused and non-fused rotary disconnect switches from 30A to 800A, providing flexibility and convenience for point-of-use US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2016 EatonOrdering information:Part number exampleER4X-60J3 PBAC lass L fuses for 800A disconnect switch 30A-800A switches: maximum number of contacts per switch : (4) 30A to 200A.

3 (8) 400A to 200A-800A switches: includes terminal shroud for line side or load units per switch one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + type4X304 stainless steel, NEMA 4X4 PPolycarbonate, NEMA 4 XER60 JAmperage rating3030A6060A100100A200200A400400A600 600A800800 AStyleBLANKF usedNNon-fusedEnclosure typeAmperageFuse type4X plastic304 stainless steel30 JER4P-30J3 PBER4X-30J3PB60 JER4P-60J3 PBER4X-60J3PB100 JER4P-100J3 PBER4X-100J3PB200 JER4P-200J3 PBER4X-200J3PB400 JER4P-400J3 PBER4X-400J3PB600 JER4P-600J3 PBER4X-600J3PB800 LER4P-800L3 PBER4X-800L3 PBFused disconnects.

4 ER4 industrialdisconnect switchesUL/cULus ListedNEMA 4X (enclosure)4X Fuse classJClass JLAC lass LSelect fuse class only if fused style disconnect switch is of poles33-polePBHandle colorBBlackHandle typePPistolAll catalog numbers provided with integral or installed lugs and black selector typeAmperage4X plastic304 stainless steel30ER4P-30N3 PBER4X-30N3PB60ER4P-60N3 PBER4X-60N3PB100ER4P-100N3 PBER4X-100N3PB200ER4P-200N3 PBER4X-200N3PB400ER4P-400N3 PBER4X-400N3PB600ER4P-600N3 PBER4X-600N3PB800ER4P-800N3 PBER4X-800N3 PBNon-fused disconnects:All catalog numbers provided with integral or installed lugs and black selector #DescriptionBAC05 BAux.

5 Contact, (1) NO type, 10A, 600 VACBAC06 BAux. contact, (1) NC type, 10A, 600 VACTSH8-3 TBCT erminal shroud, 200A switch rating, 3-poleTSH9-3 TBCT erminal shroud, 400A switch rating, 3-poleTSH10-3 TBCT erminal shroud, 600A-800A switch rating, 3-poleAccessories (ordered separately):Cat. #DescriptionBAC01 DAux. contact, 30A-100A, (1) NO type, (1) NC type, 10A, 240 VACBAC02 DAux. contact, 30A-100A, (2) NO type, 10A, 240 VACBAC03 EAux. contact, 220A-800A, (1) NO type, (1) NC type, , 125-250 VACBAC04 EAux. contact, 220A-800A, (1) NO type, (1) NC type, , 125-250 VACBAC11 EAux. contact, 220A-800A, (1) NO type, (1) NC type, 1A, 125 VACBAC12 EAux.

6 Contact, 220A-800A, (1) NO type, (1) NC type, 1A, 125 VACTSH3-3 TBTerminal shroud, 30A-100A switch rating, line side and load side, 3-poleTSH4-3 TTerminal shroud, 200A switch rating, line side, 3-poleTSH4-3 BTerminal shroud, 200A switch rating, load side, 3-poleTSH5-3 TTerminal shroud, 400A switch rating, line side, 3-poleTSH5-3 BTerminal shroud, 400A switch rating, load side, 3-poleTSH6-3 BTerminal shroud, 600A switch rating, line side or load side, 3-poleTSH7-3 TBTerminal shroud, 800A switch rating, line side or load side, 3-poleAccessories (ordered separately) US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2016 EatonDimensions (in inches):F25kA at 600 VAC; 100kA at 480 industrialdisconnect switchesUL/cULus ListedNEMA 4X (enclosure)Mounting H x W (in.)

7 AmperageH x W x D (in.)ABWeight (lbs.)3010 x 10 x x x x 10 x x x x 12 x x x x 20 x x x x 36 x x x x 36 x x x x 36 x x x stainless steel:Mounting H x W (in.)AmperageH x W x D (in.)ABWeight (lbs.)3012 x 10 x x x x 13 x x x x 13 x x x x 21 x x 3940051 x 37 x x 18660051 x 37 x x 21480051 x 37 x x 214 Fused polycarbonate or fiberglass:Enclosures 100A are polycarbonate; flammability rating: UL 200A are fiberglass; flammability rating: UL H x W (in.)AmperageH x W x D (in.)ABWeight (lbs.)3010 x 8 x x x x 8 x x x x 10 x x x x 16 x x x x 30 x x x x 36 x x x x 36 x x x stainless steel:Mounting H x W (in.)

8 AmperageH x W x D (in.)ABWeight (lbs.)309 x 9 x x x x 9 x x x x 13 x x x x 17 x x 3140037 x 32 x x 10360051 x 37 x x 18780051 x 37 x x 189 Non-fused polycarbonate or fiberglass:Enclosures 100A are polycarbonate; flammability rating: UL 200A are fiberglass; flammability rating: UL of polesSwitch amperage ratingDisc. switchFuse typeVACVDCMax. HP rating at 600 VACSSCR at 600 VAC330 RDF30J-3J60025020200kA60 RDF60J-3J60025050100 RDF100J-3J60025075200 RDF200J-3J600N/A150400 RDF400J-3J600250350600 RDF600J-3J600600500800 RDF800L-3L600600500 switch ratings:Non-fusedNo. of polesSwitch amperage ratingDisc.

9 SwitchVACMax. HP rating at 600 VACSSCR at 600 VAC330RD30-360025100kA60RD60-360050100kA 100RD100-36005025/100kAF200RD200-3600200 200kA400RD400-3600350200kA600RD600-36003 50200kA800RD800-3600500100kA