Example: bankruptcy

2MOPP/250VAC - AC/DC and DC/DC Converters, Switching ...

FeaturesRegulated Converter Long 5 year warranty 2 MOPP/250 VAC Suitable for built in Class II applications Wide input voltage range (85-264 VAC) Low leakage current (<75 A) 5000m operation Active power factor correction Connector set availableDescriptionThe RACM100 is a compact 3 x 2 high efficiency AC/DC power supply with 2xMOPP 3rd Ed. safety approval for medical applications. The range has now been extended to include open frame models (/OF suffix). Like the original enclosed versions, the RACM100/OF series are space-saving universal input voltage power supplies (85-264 VAC), with 4kVAC isolation, PFC, no minimum load and can be used at ambient temperatures of between -25 C and +85 C. The 12V, 15V, 24V or 48V output voltages are fully protected and have tolerances of less than over the entire input voltage range and less than over the entire load range.

www.recom-power.com REV.: 9/2018 MED-5 oerer pecco mere T , AC, o er wrm-p RACM100 Series DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material enclosed aluminum Dimension (LxWxH)

Tags:

  Types, Power, Enclosed

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 2MOPP/250VAC - AC/DC and DC/DC Converters, Switching ...

1 FeaturesRegulated Converter Long 5 year warranty 2 MOPP/250 VAC Suitable for built in Class II applications Wide input voltage range (85-264 VAC) Low leakage current (<75 A) 5000m operation Active power factor correction Connector set availableDescriptionThe RACM100 is a compact 3 x 2 high efficiency AC/DC power supply with 2xMOPP 3rd Ed. safety approval for medical applications. The range has now been extended to include open frame models (/OF suffix). Like the original enclosed versions, the RACM100/OF series are space-saving universal input voltage power supplies (85-264 VAC), with 4kVAC isolation, PFC, no minimum load and can be used at ambient temperatures of between -25 C and +85 C. The 12V, 15V, 24V or 48V output voltages are fully protected and have tolerances of less than over the entire input voltage range and less than over the entire load range.

2 The RACM100/OF series is certified to medical safety standard IEC/ES/EN-60601-1 3rd Edition and feature BF rated outputs with less than 75 A leakage current. It has a built-in Class B EMI filter and comes with a five year : 9/2018 MED-1100 WattEnclosed &Open FrameCase StyleSingle Output2 MOPP250 VACIEC/EN60601 certifiedANSI/AAMI ES60601 certifiedEN55011 certifiedCISPR11 FCC Part 15E314885 Selection GuidePart Input Output Output Input power Efficiency Max. CapacitiveNumber Voltage Range Voltage Current @ No Load typ. Load (1) [VAC] [VDC] [A] [W] [%] [ F]RACM100-12S (1) 85-264 12 91 6950 RACM100-15S (1) 85-264 15 92 4450 RACM100-24S (1) 85-264 24 92 1750 RACM100-48S (1) 85-264 48 91 430 Case Style (2)SingleOutput PowerOutput VoltageModel NumberingRACM100- __ S/ __Notes: Note2: without suffix, standard enclosed case add suffix /OF for open frame styleNotes: Note1: Max Cap Load is tested at minimum input and full resistive loadExamples:RACM100-12S = 12 Vout, standard enclosed caseRACM100-24S/OF = 24 Vout, open frame.

3 9/2018 MED-2AC/DC ConverterSpecifications (measured @ Ta= 25 C, 250 VAC, full load and after warm-up)RACM100 SeriesBASIC Voltage85 VAC120 VDC264 VAC370 VDCI nput Current115 VAC, fulll load230 VAC, full Currentcold start, 230 VAC60 ANo load power Frequency RangeAC Input47Hz63 HzOutput Voltage Trimming Load0% power Time1sRise Time20msHold up Time115 VAC, full load16msInternal Operating Frequency60kHzOutput Ripple and Noise(measured @ 20 MHz BW)12 VDC, with 10 F/25V MLCC15 VDC, with 10 F/25V MLCC24 VDC, with 1 F/50V MLCC48 VDC, with F/100V MLCC120mVp-p150mVp-p160mVp-p340mVp-pEffi ciency vs. Load Efficiency vs. Input Voltage102030405060708090100100806040907 0503020100 Efficiency [%]Output Load [%]115 VAC230 VAC8510512514516518520522524526410080604 09070503020100 Efficiency [%]Input Voltage [VAC]50% load100% loadPower Factor vs. LoadLine Factor [ ]30405060708090100 Output Load [%]115 VAC230 VAC1008060907050203040 Output Load [%]85105100125145165185205225245264 Input Voltage [VAC] : 9/2018 MED-3AC/DC ConverterSpecifications (measured @ Ta= 25 C, 250 VAC, full load and after warm-up)RACM100 SeriesREGULATIONSP arameterConditionValueOutput Accuracy230 VAC, full load Regulationlow line to high line, full load Regulation0% to 100% load10% to 100% Peak Deviationload step from 50% - 75% change at Vout Recovery Timeload step from 50% - 75% change at s500 s ConditionValueInput Fuseinternal line and neutral / 250 VAC, slow blow typeShort Circuit Protection (SCP)continuous, auto-recoveryOver Load Protection (OLP)% of Iout rated (Hiccup)115% min.

4 / 150% Voltage Protection (OVP)% of Vout nominal (Latch off)115% min. / 135% Voltage (5)tested for 1 minuteI/P to O/PI/P to CaseO/P to Resistance500 VDC100MW GradereinforcedLeakage Current264 VAC75 A of Protectionworking voltage 250 VAC/continuous2 MOPP Medical Device Classificationbuilt-in power supplyInternalclearancecreepage> > : Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltageENVIRONMENTALP arameterConditionValue Operating Temperature Rangerefer to derating graph-25 C to +85 Cfull load, 230 VACenclosedopen frame-25 C to +60 C-25 C to +55 CTemperature Coefficient Altitude5000m Humiditynon-condensing5% to 95% RHPollution DegreePD2 Thermal ShockMIL-STD-810 FShockIEC60068-2-27 VibrationIEC60068-2-6 MTBF according to MIL-HDBK-217F, full load, +25 x 103 hourscontinued on next : 9/2018 MED-4AC/DC ConverterSpecifications (measured @ Ta= 25 C, 250 VAC, full load and after warm-up)RACM100 SeriesDerating Graph(@ Chamber and natural convection ) enclosed /OF version-25-20020407060-10103050809085551 101001008060409070503020100 Output Load [%]Ambient Temperature [ C]115 VAC230 VAC-25-20020407060-101030508090855511010 01008060409070503020100 Output Load [%]Ambient Temperature [ C]115 VAC230 VACSAFETY AND CERTIFICATIONSC ertificate Type (Safety)Report / File NumberStandard Medical Electric Equipment, General Requirements for Safety and Essential Performance E314885 No.

5 60601-1:14 ANSI/AAMI ES60601-1:2005 + A2:2010 Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB Scheme)1408016004 IEC60601-1:2005 + C2:2007, 3rd EditionEN60601-1:2006 Information Technology Equipment - General Requirements for Safety (LVD)TW1708008-001EN60950-1:2006 + A2:2013 Information Technology Equipment - General Requirements for SafetyIEC60950-1:2005, 2nd Edition + A2 TC 004/2011 TP TC 004/2011 RoHs2+RoHS-2011/65/EU + AM-2015/863 EMC Compliance (Medical)ConditionsStandard / CriterionMedical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and testsEN60601-1-2:2015 Industrial, scientific and medical equipment Radio frequency disturbance characteristics Limits and methods of measurementEN55011:2009 + A1:2010 Class B Conducted, Class A RadiatedIndustrial, scientific and medical equipment - Radio frequency disturbance characteritics - Limits and methods of measurementCISPR11:2009 + A1:2010 Class B Conducted, Class A RadiatedESD Electrostatic discharge immunity testAir 15kV; Contact 8kVIEC61000-4-2:2008 Radiated, radio-frequency, electromagnetic field immunity test10V/m (80-2700 MHz)27V/m (385 MHz)28V/m (450 MHz)IEC61000-4-3:2006 + A2:2010 Fast Transient and Burst ImmunityAC power Port: 2kVIEC61000-4-4:2012 Surge ImmunityAC Port:L-N= 1kVL-GND= 2kVIEC61000-4-5:2005 Immunity to conducted disturbances, induced by radio-frequency :2013 power Frequency Magnetic Field50Hz, 30A/mIEC61000-4-8:2009 Voltage Dips and InterruptionsDips: >95%; 30%.

6 Interruptions >95%IEC61000-4-11:2004 Limits of Harmonic Current EmissionsEN61000-3-2:2005 + A2:2009, Class DLimits of Voltage Fluctuations and FlickerEN61000-3-3:2013continued on next : 9/2018 MED-5AC/DC ConverterSpecifications (measured @ Ta= 25 C, 250 VAC, full load and after warm-up)RACM100 SeriesDIMENSION and PHYSICAL CHARACTERISTICSP arameterTypeValueMaterialenclosed aluminumDimension (LxWxH)enclsodedopen x x x x frame210g150gcontinued on next pageEMC Compliance (Industrial)ConditionsStandard / CriterionLimitations on the amount of electromagnetic intererence allowed from digital & electronic devices47 CFR FCC Part 15 Subpart B, Class BMethods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHzANSI :2014 Electromagnetic compatibility of multimedia equipment Emission RequirementsEN55032:2015+AC:2013, Class BInformation technology equipment - Immunity characteristics - Limits and methods of measurementEN55024:2010+A1:2015 ESD Electrostatic discharge immunity testAir 8kV; Contact 6kVIEC61000-4-2:2008, Criteria ARadiated, radio-frequency, electromagnetic field immunity test3V/m (80-1000 MHz)20V/m (80-1000 MHz)3V/m ( )10V/m ( :2006 + A2:2010, Criteria AFast Transient and Burst ImmunityDC Port: 2kVIEC61000-4-4:2012, Criteria ASurge ImmunityDC Port: 1kVIEC61000-4-5:2014, Criteria AImmunity to conducted disturbances, induced by radio-frequency fieldsDC power Port 3V + 20 VIEC61000-4-6:2013, Criteria APower Frequency Magnetic Field50Hz/60Hz 1A/m50Hz/60Hz 10A/mIEC61000-4-8:2009, Criteria AVoltage Dips and InterruptionsDips: >95%; 60%.)

7 30%Interruptions >95%IEC61000-4-11:2004, Criteria AIEC61000-4-11:2004, Criteria BLimits of Harmonic Current EmissionsEN61000-3-2:2014, Class DLimits of Voltage Fluctuations and FlickerEN61000-3-3 : 9/2018 MED-6AC/DC ConverterSpecifications (measured @ Ta= 25 C, 250 VAC, full load and after warm-up)RACM100 Seriescontinued on next Drawing enclosed (mm)Side ViewBottom ViewTop ViewConnection via Connector AC Input (CON1)Pin #Pin Header 1 AC/L3 Output Connector (CON2)Pin #Pin Header1,2 -Vout3,4 + = fixing centersCrimp Terminal AWG Range: 18-22 AWGS uggested Plug: RECOM Connector SET OFTolerance: : 9/2018 MED-7AC/DC ConverterSpecifications (measured @ Ta= 25 C, 250 VAC, full load and after warm-up)RACM100 SeriesPACKAGING INFORMATIONP arameterTypeValuePackaging Dimension (LxWxH) cardboard box enclosed x x x x Quantityenclosed case10pcsopen frame25pcsStorage Temperature Range-40 C to +85 CStorage Humiditynon-condensing5% to 95% RHThe product inf ormation and specifications may be subject to changes even without prior written product has been designed for various applications; its suitability lies in the responsibility of each customer.

8 The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonabl y be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against an y damage claims in connection with the unauthorized use of RECOM products in such safety-critical Drawing Open Frame (mm)FC via Connector AC Input (CON1)Pin #Pin Header 1 AC/L3 Output Connector (CON2)Pin #Pin Header1,2 -Vout3,4 + = fixing centersCrimp Terminal AWG Range: 18-22 AWGS uggested Plug: RECOM Connector SET OFTolerance: ViewTop View


Related search queries