Example: confidence

2P Arktite Circuit Breaking CPS Receptacles and CPP Plugs ...

US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessArktite Circuit Breaking CPSR eceptacles and CPP PlugsDelayed ActionFactory SealedCl. I, Div. 1 & 2, Groups C, DExplosionproofWet LocationsApplications:CPS Receptacles , angle and straight types,and CPP Plugs are used: With portable electrically operateddevices such as motor-generator sets,compressors, conveyors, portable tools,lighting systems and similar equipment In locations which are hazardous due tothe presence of flammable vapors orgases In damp or corrosive locations In petroleum refineries, chemical andpetrochemical plants, and other processindustry facilities where similar hazardsexistFig. 1 Fig. 2 Fig. 32 PGrounding: NEC Article 501 and CEC Part 1 Section18 requires that metal frames orexposed non-current-carrying metalparts of portable devices used inhazardous locations be groundedthrough an extra conductor in theportable cord CPS Receptacles and CPP Plugs areprovided with an extra grounding pole In Plugs , provision is made forattachment of the grounding wire to thegrounding pole.

2P 1346 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright© 2013 Eaton’s Crouse-Hinds Business CPS152 – Single gang angle type CPS152 – Two ...

Tags:

  Receptacles, Circuit, Breaking, Arktite, Arktite circuit breaking cps receptacles and

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of 2P Arktite Circuit Breaking CPS Receptacles and CPP Plugs ...

1 US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessArktite Circuit Breaking CPSR eceptacles and CPP PlugsDelayed ActionFactory SealedCl. I, Div. 1 & 2, Groups C, DExplosionproofWet LocationsApplications:CPS Receptacles , angle and straight types,and CPP Plugs are used: With portable electrically operateddevices such as motor-generator sets,compressors, conveyors, portable tools,lighting systems and similar equipment In locations which are hazardous due tothe presence of flammable vapors orgases In damp or corrosive locations In petroleum refineries, chemical andpetrochemical plants, and other processindustry facilities where similar hazardsexistFig. 1 Fig. 2 Fig. 32 PGrounding: NEC Article 501 and CEC Part 1 Section18 requires that metal frames orexposed non-current-carrying metalparts of portable devices used inhazardous locations be groundedthrough an extra conductor in theportable cord CPS Receptacles and CPP Plugs areprovided with an extra grounding pole In Plugs , provision is made forattachment of the grounding wire to thegrounding pole.

2 In addition, directconnection is provided between plugand receptacle housings and thegrounding pole. In the receptacle,grounding is accomplished through theconduit systemInterchangeability of Plugswith Non-hazardousLocation Receptacles : 30 ampere CPP Plugs can also be usedwith standard 30 ampere AR Arktitereceptacles of the same style andnumber of poles, thus permittingportable devices suitable for use inhazardous locations to be connected toreceptacles in both hazardous and non-hazardous areasNote:Equipment to be used in hazardous areas must besuitable for use in the specific hazardous Materials: Receptacle housings die cast copper-free aluminum EDS Back boxes Feraloy iron alloy( )/Copper-free aluminum (Canada) Other back boxes Feraloy iron alloy Plug exteriors copper-free aluminum orKrydon fiberglass-reinforced polyestermaterial (see listings) Insulation all Receptacles and Plugs Krydon fiberglass-reinforced polyestermaterial Pressure or solder contacts brass Crimp/solder contacts leaded redbrassStandard Finishes: Copper-free aluminum aluminumacrylic paint Feraloy electrogalvanized andaluminum lacquer Fiberglass-reinforced polyester natural(red, white) Brass natural Leaded red brass electro-tin-plateElectrical Rating Ranges: Angle type 20 and 30 amperes; 125and 250 VAC Straight type 20 amperes.

3 125 and 250 VACC ertifications andCompliances: NEC/CEC: Class I, Division 1 and 2, Groups C, D UL Standard: 1203 CSA Standard: No. 30 Features: The delayed action feature permits theplug to be used as an emergency push-pull switch CPS Receptacles are equipped with arotating mechanism which preventscomplete withdrawal of the CPP plug inone continuous movement. Details ofoperation are illustrated and explainedbelowFigure 1shows a CPS angle typereceptacle assembly with CPP plugfully 2shows the plug withdrawnuntil it is stopped by the delayed actionmechanism. In this position the circuithas been broken and the arc has beensnuffed in the contact chambers. To completely withdraw the plug asshown in Figure 3, the delayed actionrelease lever must be rotated counterclockwise. The time required toactuate the mechanism permitsdissipation of the arc-generated heatbefore contacts and arcing chambersare opened to the atmosphere.

4 Wheninserting the plug, the reverseprocedure is followed. CPS Receptacles are factory sealed tosimplify installation and wiring externalseals are not required Series 152 Receptacles have top hingedcover design, with 45 downward angledreceptacle housing, to provide superiorenvironmental protection fromaccumulations of dust, snow, ice, andwater Back boxes used for angle typereceptacles are standard EDS are listed with single andtwo gang bodies and dead end orthrough feed hubs 1/2" to 1" sizes Back boxes used for straight typereceptacles are available with a variety ofhub arrangements in 1/2" and 3/4" sizes All Receptacles and 30 ampere Plugs areprovided with pressure terminals forease of field wiring. 20 ampere plugshave solder US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessArktite Circuit Breaking CPSR eceptacles and CPP PlugsDelayed ActionFactory SealedCl.

5 I, Div. 1 & 2, Groups C, DExplosionproofWet Locations2 POptions:The following special options are available from factory by adding suffix to Cat. #:DescriptionSuffixMaterial: copper-free aluminum, natural finish, is available on certain back boxes. See interior rotated 221/2 to right (viewed from face) and plug changed to match. 30 ampere units of Receptacles and EFS/EFD or EDS series devices, such as pilot lights, switches, pushbutton stations, etc., can befurnished using three, four and five gang arrangements other than those listed can be Inches:Angle Type ReceptaclesSeries 152 Series 532 and 732a=31/2for single gang73/16for two gangStraight Type Receptacles20 Ampere PlugsCat. #a b cdCPP516 83/867/813/419/16 CPP512 751/213/419/16 These dimensions are approximate and vary with cable size. 20 amp Plugs are furnished with solder terminations at standard, ground contacts havepressure Ampere US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessCPS152 Single gang angle typeCPS152 Two gang angle typeCPS152R Receptacle unit onlyCPP Plugs withmechanical cable grip and neoprene bushingStyle 2 Grounded Through Extra Pole and ShellRatingDescriptionHubSize(In.)

6 Single GangReceptacleAssemblyCat. #Two GangReceptacleAssemblyCat. #CableDia.(In.)PlugwithAluminumHandlesCa t. #Plug withHigh ImpactMoldedCompositionHandleCat. #ReceptacleUnit onlyCat. #20A, 1 HP,125 250 VAC,60 hertz,20A, 18 VDCDeadEnd1/2 CPS152 101* CPS152 102*3/4 CPS152 201* CPS152 202*1 CPS152 301* CPS152 302*2-wire, to .625 CPP516 CPP512 CPS152 RThroughFeed1/2 CPS152 111* CPS152 112*3/4 CPS152 211* CPS152 212*1 CPS152 311* CPS152 312*30A, 11/2HP,125 250 VAC,60 hertz,7A, 1/2HP,480 VAC**,60 hertzDeadEnd1/2 CPS532 101 CPS532 1023/4 CPS532 201 CPS532 2021 CPS532 301 CPS532 3022-wire, to .875 CPP4553 CPS532 RThroughFeed1/2 CPS532 111 CPS532 1123/4 CPS532 211 CPS532 2121 CPS532 311 CPS532 31230A, 3 HP,125 250 VAC,60 hertz,7A, 1 HP,480 VAC**,60 hertzDeadEnd1/2 CPS732 101 CPS732 1023/4 CPS732 201 CPS732 2021 CPS732 301 CPS732 3023-wire, to.

7 875 CPP4752 CPS732 RThroughFeed1/2 CPS732 111 CPS732 1123/4 CPS732 211 CPS732 2121 CPS732 311 CPS732 312*Back boxes are available in copper-free aluminum. To order, add suffix SA to the Cat. No.** CSA certified units are rated at 600 VAC at 7A. Receptacles will take any of the Plugs grouped in the bracket opposite the receptacle listings. 20 amp Plugs are furnished with solder terminations at standard, ground contacts have pressure Circuit Breaking CPSR eceptacles and CPP PlugsDelayed ActionFactory SealedCl. I, Div. 1 & 2, Groups C, DExplosionproofWet Locations2P}}} US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eaton s Crouse-Hinds BusinessCPS straight type shown with plugCPS Straight Type2-wire, 3-pole20A, 1HP, 125 250 VAC, 60 400 hertz, 20A, 18 VDCCPS Dead EndHubSize (In.)AssemblyCat. #BodyCat. #1/2 CPS14 120 CPS1203/4 CPS14 20 CPS20 CPS Receptacle UnitWith Spring DoorTypeCat.

8 #CPS Receptacle Unit with Spring DoorCPS14 RCPP PlugsWith Mechanical Cable Grip and Neoprene BushingWith aluminum handleWith high impact molded compositionhandleCableDia. (In.)Aluminum Cat. #CompositionCat. #.312 to .625 CPP516 CPP512 CPS Through FeedHubSize (In.)AssemblyCat. #BodyCat. #1/2 CPS14 121 CPS1213/4 CPS14 21 CPS21 Arktite Circuit Breaking CPSR eceptacles and CPP PlugsDelayed ActionFactory SealedCl. I, Div. 1 & 2, Groups C, DExplosionproofWet Locations2P