Example: confidence

3 Port Direct Operated Solenoid Valve Rubber Seal …

3 Port Direct Operated Solenoid ValveRubber SealSeries SY100 SpecificationsFluidAmbient and fluid temperature ( C)Response time (ms) (1)Max. operating frequency (Hz)LubricationMounting positionImpact/Vibration resistance (m/s2) (2)EnclosureAir 10 to 50 C (No freezing. Refer to page 4-18-4.)10 or less20 Not requiredUnrestricted150/30 DustproofSolenoid SpecificationsElectrical entryCoil rated voltage (V)DCAC 50/60 HzSurge voltage suppressorIndicator lightPower consumption (W)DCApparent power (VA)AC100 V110 V [115 V] 200 V220 V [230 V] 24, 12, 6, 5, 3 10 to +10%Grommet (G)/(H), L plug connector (L)M plug connector (M) (With indicator light: ) (With indicator light: ) (With indicator light: )[ (With indicator light: )] (With indicator light: )[ (With indicator light: )] It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.

3 Port Direct Operated Solenoid Valve Rubber Seal Series SY100 Specifications Fluid Ambient and fluid temperature (°C) Response time …

Tags:

  Direct, Valves, Rubber, Solenoid, Operated, Ports, Port direct operated solenoid valve rubber

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 3 Port Direct Operated Solenoid Valve Rubber Seal …

1 3 Port Direct Operated Solenoid ValveRubber SealSeries SY100 SpecificationsFluidAmbient and fluid temperature ( C)Response time (ms) (1)Max. operating frequency (Hz)LubricationMounting positionImpact/Vibration resistance (m/s2) (2)EnclosureAir 10 to 50 C (No freezing. Refer to page 4-18-4.)10 or less20 Not requiredUnrestricted150/30 DustproofSolenoid SpecificationsElectrical entryCoil rated voltage (V)DCAC 50/60 HzSurge voltage suppressorIndicator lightPower consumption (W)DCApparent power (VA)AC100 V110 V [115 V] 200 V220 V [230 V] 24, 12, 6, 5, 3 10 to +10%Grommet (G)/(H), L plug connector (L)M plug connector (M) (With indicator light: ) (With indicator light: ) (With indicator light: )[ (With indicator light: )] (With indicator light: )[ (With indicator light: )] It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.

2 [Low wattage [ W] is available, too. For details, refer to catalog on page 4-18-4.]JIS SymbolSY1134 (A)SY1234 (A)Body portedBase mountedAllowable voltage (With indicator light: )100, 110, 200, 220 1324SY1 A1324 Manual overrideNon-locking push type, Locking slotted type Push-turn locking slotted typePush-turn locking lever type {SY1 4, SY1 4A only} W (With indicator light: W)(A)21 (R)3 (P)(A)23 (R)1 (P)1212 ModelValvemodelFunctionGrommetL plug connector, M plug connectorWeight (g)Operatingpressurerange(MPa)Vacuum specifications (MPa)Port size0 to to to to A34SY1234SY12 A341(P) port 100 kPA to 100 kPA to 100 kPA to 0 100 kPA to 03(R) port 100 kPA to 0 100 kPA to 0 100 kPA to 100 kPA to (P), 3(R)portM3 x x x x (A)portM3 x x x x (mm2) 3(A): 13SY1 4(A): 24(12)SY1 3(A): 15SY1 4(A): 26(14)Note 1) SY123/SY12434 and SY123/SY12434A: Supply pressure to 1(R) port and exhaust air from 3(P) 2) Value for DC.

3 Add 1 g for AC. ( ): Without flowStandardLarge flow(1)(1)(2)Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20 C, at rated voltage, without surge suppressor.)Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main Valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period)Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main Valve and armature.

4 (Values at the initial period)Made to Order Specifications(For details, refer to page 4-3-17.)For details about certified products conforming to international standards, visit us at closedNormally openType of actuation56 VSR24 VDC12 VDC6 VDC5 VDC3 VDCR ated voltageFor DC1234100 VAC200 VAC110 VAC [115 VAC] 220 VAC [230 VAC] For AC (50/60 Hz)3 portFor manifold type 30, 313 portSub-plate style For manifold type S41M3 BracketNil: Without bracketF: With bracket P piping specifications sizeNil: Without sub-plate(With gasket and screws)M3: With sub-plateManual overrideNil: Non-locking push typeB: Locking slotted typeElectrical entryG: 300 mm lead wireL: With lead wire(Length 300 mm)M: With lead wire(Length 300 mm)MN: Withoutlead wireH: 600 mm lead wireLN.

5 Withoutlead wireLO: Without connectorMO: Without connector LN and MN types are with 2 V, 12 V, 6 V, 5 V, 3 VDC/100 V, 110 V, 200 V, 220 VACG rommetL plug connectorM plug connectorStandard type(Cv: )Standard type(Cv: )5 Porting specificationsNil: For manifoldP: For body ported typeto P, R, A portStandard type( )14632 NilSZRUW ithout light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)Light/Surge voltage suppressorD: Push-turn locking slotted typeE: Push-turn locking lever typeLPLP: Body ported: Base mountedSY1 4, SY1 4A only1212 How to Order For AC voltage valves there is no S option.

6 It is already built into the rectifier circuit. For R and U , DC voltage is only SY100V100 SYSYJVKVZVTVPVGVPS070 VQVKFVQZVZVSVFNSY13 A5 LSY14 AM112 Normally closedNormally openType of actuation56 VSR24 VDC12 VDC6 VDC5 VDC3 VDCR ated voltage3 portFor manifold type 30, 313 portSub-plate type For manifold type S41 NilSZRUW ithout light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar type)With light/surge voltage suppressor (Non-polar type)M3 BracketNil: Without bracketF: With bracket P piping specifications sizeNil: Without sub-plate(With gasket and screws)M3: With sub-plateManual overrideNil: Non-locking push typeB.

7 Locking slotted typeElectrical entryG: 300 mm lead wireL: With lead wire (Length 300 mm)M: With lead wire (Length 300 mm)MN: Withoutlead wireH: 600 mm lead wireLN: Withoutlead wireLO: Without connectorMO: Without connector LN and MN types are with 2 V, 12 V, 6 V, 5 V, 3 VDCG rommetL plug connectorM plug connectorPorting specificationsNil: For manifoldP: For body ported typeto P, R, A portLarge flow type(Cv: )1 Large flow typeLight/Surge voltage suppressor14632D: Push-turn locking slotted typeE: Push-turn locking lever typeLPLP: Body ported: Base mountedLarge flow type(Cv: )Large flow type(Cv: )5SY1 4, SY1 4A only1212 How to OrderSeries rodMovable iron core assemblyFixed iron coreExhaust poppetReturn springPoppet springCoil assemblyuioResinResinResinHNBR/Stainless steelStainless steelHNBRS tainless steelStainless steel MaterialNoteComponent PartsGrayGray SY114, SY114 ANo.

8 !0!1 DescriptionSub-plateGasketSY100-74-1VJ10 0-6-8 Part PartsZinc die-castedHNBRAR P!1outiqyerwHow to Order Connector AssemblyFor DC: SY100304 AFor 200 VAC: SY100302 AFor other voltages of AC: SY100303 ASY10030 ALead wire lengthNil6101520253050300 mm600 mm1000 mm1500 mm2000 mm2500 mm3000 mm5000 mmFor 100 VAC: SY100301A!0(A)23 (R) Without lead wire: (With connector and 2 pcs. of socket) 4-3-7 Series SY100V100 SYSYJVKVZVTVPVGVPS070 VQVKFVQZVZVSVFNBody PortedGrommet (G), (H): SY1 3 (A)- -PM3(-F)12 GHL plug connector (L): SY1 3(A)- L -PM3(F)12M plug connector (M): SY1 3(A)- M -PM3(-F)12 Other dimensions are same as grommet type. Other dimensions are same as grommet type. (Mounting hole)2- (Mounting hole) (For AC) x (Piping port) (For DC) (For AC)(Light/Surge voltage suppressor)Manual override32 300(Lead wire length) (Light/Surge voltage suppressor) (for DC) (for AC) (For DC) 300(Lead wire length) (Light/Surge voltage suppressor) : 300H: 600(Lead wire length) + A + (For AC) + APR10 Series SY1004-3-8 Base Mounted (With sub-plate)Grommet (G), (H): SY1 4(A)- -M312 GHL plug connector (L): SY1 4(A)- L -M312M plug connector (M): SY1 4(A)- M -M3 12 Other dimensions are same as grommet type.

9 Other dimensions are same as grommet type. 1328(For DC) (For AC) override(Light/Surge voltage suppressor)2- (Mounting hole)G: 300H: 600(Lead wire length) x (Piping port) , H: , H : (For DC) (For AC) (Light/Surge voltage suppressor) 300(Lead wire length) (Light/Surge voltage suppressor) (For AC) (For DC) 300(Lead wire length) (For DC) (For AC) + PARPA + + PA104-3-9 Series SY100V100 SYSYJVKVZVTVPVGVPS070 VQVKFVQZVZVSVFNS eries SYMade to Order Specifications:Please contact SMC for detailed specifications, delivery and rated voltage (V)Power consumption(W)SY1 TSY1 ATInrushHolding24 DC, 12 DCSpecifications other than above are the same as standard TypeSY135SY112 Normally closedNormally openType of actuationM3 TLZ45 TMZ1 NilAStandardLarge flow capacityBody option5624 VDC12 VDCR ated voltageEntry is the same as standard products.

10 How to OrderWorking PrincipleElectrical circuit (With energy-saving circuit)1: Starting current,2: Holding current<Energy-saving Type, Electrical Power Waveform for SY112 34 T> <Energy-saving Type, Electrical Power Waveform for SY112 34AT>2 Red(+)Black( )CoilApplied voltageStandardEnergy-saving type62 msApplied voltageHigh flow typeEnergy-saving type62 ms1 DiodeLEDT imer circuit124 V0 W0 W24 V0 W0 WBody portedBase mountedLow Wattage Specifications ( W)How to OrderSY1X200 Entry is the same as standard products. Power consumption is decreased by 1/3 by reducing the wattage required to hold the Valve in an energized state. (Effective energizing time is over 62 ms at 24 VDC.)The circuit shown below reduces current consumption at holding which reduces the overall power to electrical power waveform as shown