Example: tourism industry

3 Port Solenoid Valve - SMC (Thai

3 Port Solenoid ValveSeries VP300/500/700 rohs w Built-in full-wave rectifier (AC) Noise reductionNoize is considerably reduced by changing it to DC mode with a full-wave rectifier. Reduced apparent powerConventional: VA VA Longer life expectancy:50 million cycles or more (Conventional: 20 million cycles) Based on SMC test conditions Built-in strainer in the pilot Valve Unexpected troubles due to foreign matter can be prevented. Note) Be sure to mount an air filter on the inlet side. Rubber material: HNBRO zone-resistant specification The pilot Valve poppet is made of FKM. StrainerElectrical power waveform of energy saving typeApplied voltageStandardWith power saving circuit40 ms24 V0 W0 WEnergy savingEnergy savingReduced power consumption: w [With power saving circuit] w [Standard] (Conventional: W) With DC lightPower consumption is reduced by power saving consumption is decreased by approx.

3 Port Solenoid Valve Series VP300/500/700 RoHS compliant 0.55 w 1.55 w Built-in full-wave rectifier (AC) Noise reduction Noize is …

Tags:

  Series, Valves, Solenoid, Ports, Rohs, 3 port solenoid valve, 3 port solenoid valve series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 3 Port Solenoid Valve - SMC (Thai

1 3 Port Solenoid ValveSeries VP300/500/700 rohs w Built-in full-wave rectifier (AC) Noise reductionNoize is considerably reduced by changing it to DC mode with a full-wave rectifier. Reduced apparent powerConventional: VA VA Longer life expectancy:50 million cycles or more (Conventional: 20 million cycles) Based on SMC test conditions Built-in strainer in the pilot Valve Unexpected troubles due to foreign matter can be prevented. Note) Be sure to mount an air filter on the inlet side. Rubber material: HNBRO zone-resistant specification The pilot Valve poppet is made of FKM. StrainerElectrical power waveform of energy saving typeApplied voltageStandardWith power saving circuit40 ms24 V0 W0 WEnergy savingEnergy savingReduced power consumption: w [With power saving circuit] w [Standard] (Conventional: W) With DC lightPower consumption is reduced by power saving consumption is decreased by approx.

2 1/3 by reducing the wattage required to hold the Valve in an energized state. (Effective energizing time is over 40 ms at 24 VDC.) Refer to electrical power waveform as shown VP300 Air Operated ValveSeries VPA300/500 10:44 AM Page C11(P)3(R)(A)21(P)3(R)(A)21(P)3(R)(A)2X1 (P)3(R)(A)21(P)3(R)(A)21(P)3(R)(A)2X1(P) 3(R)(A)2 XBase mountedBody portedSolenoid valveSeriesSonic conductanceC [dm3/(s bar)]Type of actuationInternal push typePush-turn locking slotted typePush-turn locking lever typeL-type plug connectorM-type plug connectorDIN terminalDIN (EN175301-803) terminalConduit terminalInternal suppressorManualoverrideElectricalentryV P300VP500VP700VP300VP500VP70012 VDC24 VDC100 VAC200 VAC110 VAC220 VAC240 VACP. 1P. 81/81/41/43/83/81/21/81/41/43/83/81 VP300/500/700 Model Selection by Operating Conditions qSolenoid Valve : Single UnitDC With surge voltage suppressor With light/surge voltage suppressor With surge voltage suppressor (Non-polar) With light/surge voltage suppressor (Non-polar)AC With light/surge voltage suppressorFeatures 10.

3 44 AM Page F13(R) port1/43(R) port3/83(R) port1/23(R) port1/23(R) port1/42(A) port1/41(P) port1/42(A) port1/42(A) port3/82(A) port3/82(A) port1/22(A) port1/23(R) port3/81(P) port1/41(P) port3/81(P) port3/81(P) port1/21(P) port1/2 Base mountedSolenoid valveSeriesEXH porttype2 to 20stations2 to 20stations2 to 20stationsCommon EXHI ndividual EXHC ommon EXHI ndividual EXHC ommon EXHI ndividual EXHVV3P3-41VV3P3-42VV3P5-41VV3P5-42VV3P7 -41VV3P7-42 Manifoldbase modelVP300VP500VP700 Applicable stations Note)P. 15 Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or VP300/500/700 Model Selection by Operating Conditions wSolenoid Valve : ManifoldFeatures 10:45 AM Page F21(P)3(R)(A)2121(P)3(R)(A)2121(P)3(R)(A )2121(P)3(R)(A)21212(A)21(P)3(R)12(A)21( P)3(R)12(A)23(R)1(P)Air operated P.

4 25P. 301/81/41/43/83/81/21/81/41/43/83/81 VPA300/500/700 Model Selection by Operating Conditions eAir Operated Valve : Single UnitSeriesSonic conductanceC [dm3/(s bar)]Type of actuationPortsizeVoltageLight/surgevolta ge suppressorManualoverrideElectricalentryB ase mountedBody portedFeatures 10:45 AM Page F33(R) port1/43(R) port3/83(R) port1/23(R) port1/23(R) port1/42(A) port1/42(A) port1/42(A) port3/82(A) port3/82(A) port1/22(A) port1/23(R) port3/81(P) port1/41(P) port1/41(P) port3/81(P) port3/81(P) port1/21(P) port1/22 to 20stations2 to 20stations2 to 20stationsVV3PA3-41VV3PA3-42VV3PA5-41VV3 PA5-42VV3PA7-41VV3PA7-42 VPA300 VPA500 VPA700P. 35 Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or EXHI ndividual EXHC ommon EXHI ndividual EXHC ommon EXHI ndividual EXHEXH porttypeSeries VPA300/500/700 Model Selection by Operating Conditions rAir Operated Valve : ManifoldSeriesManifoldbase modelApplicable stations Note)Base mountedAir operated valveFeatures 10.

5 45 AM Page F4 How to OrderSeries VP300/500/700 Rubber Seal3 Port/Pilot Poppet TypeBody Ported/Single UnitVP3425G101 ASeries357VP300VP500VP7005624 VDC12 VDCP ilot typeNilRInternal pilotExternal pilotBracketNilFWithout bracketWith bracketThread typeNilFNTRcGNPTNPTFL ight/surge voltage suppressorDC ACNilSZRUW ithout light/surge voltage suppressorWith surge voltage suppressorWith light/surge voltage suppressorWith surge voltage suppressor (Non-polar)With light/surge voltage suppressor (Non-polar)Port size01020304 SymbolPort sizeVP3001/81/43/81/2VP500VP700 Manual overrideNil: Non-lockingpush typeD: Push-turn lockingslotted typeE: Push-turn lockinglever typePressure specificationNilKStandard ( MPa)High-pressure type ( MPa)Electrical entryGrommetConduitterminalL-type plugconnectorM-type plugconnectorDINterminalDIN(EN175301-803 )terminalG: Lead wirelength 300 mmH: Lead wirelength 600 mmL: With lead wire(length 300 mm)LN:Without lead wireLO:Without connectorM: With lead wire(length 300 mm)D: With connectorY: With connectorT: Conduit terminalDO:Without connectorYO:Without connectorMN:Without lead wireMO:Without connectorG: Lead wirelength 300 mmH.

6 Lead wirelength 600 mmDCWithout light/surge voltagesuppressorCoil specificationNilTStandardWith power saving circuit (DC only)Body portedNote) Be sure to select the power sav-ing circuit type when it is continu-ously energized for a long time.(Refer to back page 7 for details.) T type is only available for DC mode. When T is selected, only Z type of light/surge voltage suppressor is available.(Note that when the electrical entry of DIN terminal type without connector is selected, only DOS and YOS are available.)Note) There is no S option for AC mode, since a rectifier prevents surge voltage generation. In the DIN terminal type, since a light is installed in the connector, DOZ, DOU, YOZ, YOU are not voltageDC12347100 VAC200 VAC110 VAC [115 VAC]220 VAC [230 VAC]240 VACAC (50/60 Hz)When using the surge voltage suppressor type, residual voltage will remain.

7 Refer to back page 7 for details. Caution LN and MN types are with 2 sockets. Refer to back page 4 when different length of lead wire for L/M-type plug connector is required. Refer to back page 5 for details on the DIN (EN175301-803) terminal.[IP65 compatible] [IP65 compatible] [IP65 compatible]Type of (Normally closed) (Normally open)Made to OrderNilX500 Pilot exhaust port with piping thread (M3) specification (Refer to page 24). CEcompliantDCAC Note) Only DIN and conduit terminal types are available for AC to the electrical entry for ) 10:45 AM Page 1 Low power consumption W (DC)Possible to use as either a selector or divider valvePossible to change from to to use in vacuum applicationsUp to 100 kPaUse external pilot type in the following cases: For vacuum or for low pressure MPa or less Please consult with SMC for use in a vacuum hold application.

8 When having P port downsized in diameter When using A port as the atmospheric releasing port, air blowerExternal PilotSpecificationsSolenoid SpecificationsResponse TimeElectrical entryCoil rated voltage (V)Allowable voltage fluctuationPower consumption (W)Apparent power (VA) Surge voltage suppressorIndicator light24, 12100, 110, 200, 220, 240 10% of rated voltage Diode (Non-polar type: Varistor)LED (Neon bulb is used for AC mode of D, Y, T.) (With light: ) (With light only) (With light: ) (With light: ) (With light only) (With light: )Grommet (G), (H)L-type plug connector (L)M-type plug connector (M)DIN terminal (D)DIN (EN175301-803) terminal (Y)Conduit terminal (T)DCAC (50/60 Hz)StandardWith power saving circuit100 V110 V[115 V]200 V220 V[230 V]240 VG, H, L, MD, Y, T It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.

9 Allowable voltage fluctuation is 15% to +5% of the rated voltage for 115 VAC or 230 VAC. Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable voltage fluctuation should be within the following range. 24 VDC: 7% to +10%12 VDC: 4% to +10%FluidType of actuationInternal pilotOperating pressure range (MPa)External pilotOperating pressure range (MPa)Ambient and fluid temperature ( C)Max. operating frequency (Hz)Manual overridePilot exhaust typeLubricationMounting orientationImpact/Vibration resistance (m/s2) Note)EnclosureStandardHigh-pressure typeStandardHigh-pressure typePilot pressure rangeNote) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main Valve and armature in both energized and de-energized states every once for each condition.

10 (Values at the initial period)Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main Valve and armature. (Values at the initial period)VP342VP542VP742 Standard ( to )High-pressure type ( to )Standard ( to )High-pressure type ( to )Standard ( to )High-pressure type ( to )Response time ms (at MPa)13 or less17 or less14 or less18 or less19 or less22 or lessWithout light/surge voltage suppressorWith light/surge voltage suppressorS, Z type38 or less42 or less39 or less43 or less44 or less47 or lessR, U type16 or less20 or less17 or less21 or less22 or less25 or lessAC38 or less42 or less39 or less43 or less44 or less47 or lessNote) Based on dynamic performance test, JIS B 8375-1981.