PPoorrttss::AA--DDIINN:: DDNN6655 -- DDNN110000 MMRR --DDIINN:: DDNN2255 -- DDNN5500 MMRR--AANNSSII:: 11"" -- 22""AARR--DDIINN:: DDNN6655 -- DDNN115500 AARR--AANNSSII:: 22 11//22""-- 66""FFllaannggeess::DDIINN:: PPNN1166 -- PPNN4400 AANNSSII:: 115500 -- 330000 LLbbss FFllooaattiinngg TTrraannss ffllooww ""ddeessiiggnn"".. LLeeaakk--ffrreeee LLooww ttoorrqquuee ffoorr flanged ball valvesModels A, MR and ARModel MRModels A and ARGlobal Filtration TechnologyMBC 021 rev 13-03-04 DDeessccrriippttiioonn33--WWaayy ffllaannggeedd bbaallll vvaallvveessTransflow DesignParker Arlon ball valves are designed totransfer flow, without interruption orshutdown. Typical applications are:Lubrication Systems, Shaft-Sealing OilSystems, Fluid Power Filtration Systems -Fluid Power Heat Exchange Arlon s continuous - flow transfervalve design guarantees shock-freeuninterrupted flow while simultaneouslydivertering both inlet and outlet flowsfrom one component to its twin, withoutaltering the continuity of full flowthrough the valve.

Mounting and Maintenance 3-Way flanged ball valves Storage 1. During storage the ball valve should be sealed against the entry of contaminant, which may cause damage to the ball

Tags:

  Model, Valves, Ball, Flanged, Way flanged ball valves models a, Flanged ball valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 3-Way flanged ball valves Models A,MR and AR - …

1 PPoorrttss::AA--DDIINN:: DDNN6655 -- DDNN110000 MMRR --DDIINN:: DDNN2255 -- DDNN5500 MMRR--AANNSSII:: 11"" -- 22""AARR--DDIINN:: DDNN6655 -- DDNN115500 AARR--AANNSSII:: 22 11//22""-- 66""FFllaannggeess::DDIINN:: PPNN1166 -- PPNN4400 AANNSSII:: 115500 -- 330000 LLbbss FFllooaattiinngg TTrraannss ffllooww ""ddeessiiggnn"".. LLeeaakk--ffrreeee LLooww ttoorrqquuee ffoorr flanged ball valvesModels A, MR and ARModel MRModels A and ARGlobal Filtration TechnologyMBC 021 rev 13-03-04 DDeessccrriippttiioonn33--WWaayy ffllaannggeedd bbaallll vvaallvveessTransflow DesignParker Arlon ball valves are designed totransfer flow, without interruption orshutdown. Typical applications are:Lubrication Systems, Shaft-Sealing OilSystems, Fluid Power Filtration Systems -Fluid Power Heat Exchange Arlon s continuous - flow transfervalve design guarantees shock-freeuninterrupted flow while simultaneouslydivertering both inlet and outlet flowsfrom one component to its twin, withoutaltering the continuity of full flowthrough the valve.

2 A tight shut-off of theidle component is provided to allow foreasy maintenance. Parker Arlon ballvalves do a leak-free, efficient job in awide variety of applications for fluids, andprocess media. (fig. 1)MountingEnsure the balls are aligned in parallelwith the couplingshaft when the change-over lever is against the stop on thedetention plate. When fitting valves , careshould be taken to ensure they are notsubjected to any extreme loads appliedvia heat exchangers or associated valve connections should never beexposed to torsional stresses of any kind. Springloaded ball -Seat DesignThe absolute tightness of the Parker Arlon3-way 2-seat flanged ball valves isobtained by the floating ball designwhich gives an automatic, positive jacks or locking flanges are notnecessary. To guarantee leakfree functioning underthe most severe system-circumstances,the valves are provided with twospringloaded glass fibre reinforced PTFE ball seats one in port 'A' and one inport 'B', resulting in an extremely lowchange-over torque at equalizedpressure.

3 As there is no ball seat mounted on port'C' it is avoided that this port will be shutoff (see valve torque data). (fig. 2)Stem Seal DesignThe stem seal design consists of a radialand axial glass fibre reinforced PTFE bushing with a PTFE back-up ringprotected double "O"- ring sealingconstruction. (fig. 3)Equalizing LineBefore changing over, the pressure in thesystem has to be equalized to avoidpressure shocks and air locks. Ourthreeway ball valves offer the possibillityto mount an integrated pressureequalizing ball StandardsMax. working pressure A:- PN 1616 barDIN 2633 Max. working pressure MR/AR:- PN 1616 barDIN 2633- PN 4040 barDIN 2635-150 lbsANSI lbsANSI :- A: DN65 - DN100- MR: DN25 - DN50 1 - 2 - AR: DN65 - DN150 21/2 - 6 Maximum operating pressure accordingto the relevant "flange rating". Themaximum seal operating temperature isfor NBR : -40 C / +100 Cfor FPM : -20 C / +200 Cfor CR: -45 C / +100 CWhen operating temperatures below -10 C: Utilize stainless steel housings and leaktest according toAPI-598 or DIN 3230.

4 The transflowdesign and available materials complywith of ConstructionThe A model is available with:- Casted body and flanges - GGG50MR American standard:- Body:Moulded steel- Flanges: Moulded steel ASTM-A 105 grade BMR European standard:- Body:Moulded steel S355J2G3- Flanges: Specified in DIN normAR American standard:- Body:Cast steel ASTM-A 216 WCB- Flanges: Moulded steel ASTM-A 105 grade BAR European standard:- Body:Cast steel GS 45- Flanges: Specified in DIN normThe floatingball and stem are made ofStainless steel AISI-316 as a standard forall ball valve types. All pressure containing parts are coveredby certificates in accordance with:EN 10204 for valves type "A", EN 10204 for valves type "AR", EN 10204 for valves type "MR".Surface protectionAll ball valves are delivered from factoryprovided with a primer suitable for allgeneral paint systems.(fig. 1)(fig. 2)(fig. 3)2 Global Filtration TechnologyMMoouunnttiinngg aanndd MMaaiinntteennaannccee33--WWaayy ffllaannggeedd bbaallll vvaallvveessStorage1.

5 During storage the ball valve should besealed against the entry of contaminant,which may cause damage to the balland Ensure that the change-over lever isplaced against its stop on the detentionplate to protect the seals of Transfer ball Valveswith Flexible Coupling shaftEnsure the balls are aligned in parallel withthe couplingshaft when the change-overlever is against the stop on the detentionplate. When fitting valves , care should betaken to ensure they are not subjected toany extreme loads applied via heatexchangers or associated vessels. The valveconnections should never be exposed totorsional stresses of any kind. If operational pressures exceed 5 bar thevalves should be pressure equalized priorto change-over ( valves with integratedequalizing lines or separated equalizinglines between vessels should be used).Ensure flanges are square when of Transfer ball valves ,Single or Rigidly CoupledEnsure the balls are aligned in parallelwhen the change-over lever is against thestop on the detention plate.

6 When fittingvalves, care should be taken to ensure theyare not subjected to any extreme loadsapplied via heat exchangers or associatedvessels. The valve connections shouldnever be exposed to torsional stresses ofany kind. If operational pressures exceed 5bar the valves should be pressureequalized prior to change-over (valveswith integrated equalizing lines orseparated equalizing lines between vesselsshould be used). Ensure flanges are squarewhen operate change-over ball valves ,pressure must be equalized on both sidesof installation and all free air expelled fromsystems. This prevents excessive loadsbeing applied to change-over levers andairation of system fluid. Change-over iscarried out as follows:1. Open vent valve unit not in service;2. Open equalizing line;3. Close vent valve when all free air hasbeen expelled from system;4. When pressure has equalized, valve canbe changed over in one singlemovement of change-over lever (90 turn L-bore and 180 turn T-bore).

7 Extreme force should not be used;5. On completion of change-overequalizing line must be hrend der Lagerung und desTransports sollen die Anschl e derArmatur abgedichtet dein, damit keineunerw nschten Fremdk rper in dieAnschl e eindringen k nnen. Gleichzeitigmuss darauf geachtet werden, dass derSchathebel gegen Anschlag gesetzt der Doppeldreiwege-Wechselkugelh hne mit Kupplungs-gest nge und WellengelenkenDie Parker Arlon Wechselkugelh hnem ssen so montiert werden, dass dieAnschlagscheiben gegen bergestellt sindund mittels der Kupplungsgest ngesgesichert werden. Bei der Montage derWechselkugelh hne m ssenaussergew hnliche Spannungen auf dieArmatur vermieden werden. Die Anschl e d rfen auf keinen Fall aufTorsion belastet werden und die Flanschem ssen in gerader Linie stehen. DerSchalthebel soll immer gegen denAnschleg gestellt werden. Ist derArbeitsdruck h her als 5 bar, so muss - bevor eine Umschaltung erfolgen kann -ein Druckausgleich der Doppeldreiwege-(starrgekuppelt) und Einfachdreiwege-Wechselkugelh hneDiese m ssen so montiert werden, dassder Schalthebel die Anschlagscheibesichert.

8 Sonst wie oben ernante der Einfach- oder Doppeldreiwege-Wechselkugelh hn umgeschaltet werdenkann, muss die in Betrieb zu setzendeSystem-h lfte entl ftet uns ausgeglichenwerden, damit keine Luft in das Systemdringen kann. Der Umschaltvorgang sollwie folgt ausgef hrt werden:1. Die in Betrieb zu setzende System-H lfteentl ften;2. Die Ausgleichsleitung ffnen;3. Entl ftungshahn schliessen, nachdemdas System entl ftet ist;4. Den Wechselkugelhahn mit einerBewegung umschalten bis zumAnschlag (leichter Schlag 90 GradDrehung f r T-bore und 180 GradDrehung f r L-bore);5. Ausgleichsleitung nach cautions durant le stockageLes orifices entr e et sortie des vannesdoivent tre prot g s afin d viter que desimpuret s penetrent a l int rieur etendommagement la sph re et les faut veiller ce que le levier soitmaintenu en position but e contre l ergotd indexation afin de pr venir touted formation des des vannes cardansLes sph res doivent tre cal es etmaintenues en position parallele contre labut e par la barre d accouplement.

9 Lorsdu montage sur tuyauteries, les liasions nedoivent pas supporter le poids dur frigerant et ne subir aucune force la pression de travail exc de 5 bar, ilconvient d adapter s parement o sur lavanne elle-m me un syst med quipression qui quilibrera le syst meavant de pratiquer une op ration detransfert. Les brides doivent tre mont esen parfait des vannes transfertsimples o accoupl es rigideLes sph res doivent tre cal es etmaintenues en position parllele contre labut chaque manoeuvre, il faut quilibrerla pression et purger l autre partie dusyst me, ceci afin d viter l entr e d air. cetransfert s effect e de la facon suivante:1. Ouvrez le robinet de purge non enservice;2. Ouvrez le ligne d quilibrage;3. Fermez le robinet de purge quand lesyst me est vide d air;4. Apr s equilibrage de la pression, lesvannes peuvent tre commut es en une operation. (Tournez 90 L-bore et 180 T-bore). L operation doits effectuer normalement, sans effortimportant;5.

10 Apr s cette op ration, fermez la ligned Filtration TechnologyDDiimmeennssiioonnssMMooddeell AAThreeway transfer ball valveDouble threeway transfer ball valve rigidly coupledNm = change-over torque at equalized pressure. All sizes in mm. RS = Rigid Size (No other sizes available)4 Global Filtration TechnologyTypeDNLL1hRkgNmA31031035015515 5175158158170350350350373759151520658010 0A30030034578781273030403503503506580100 TypeDNRSkgNmRTypeDNFSkgNmRA4804805108080 1353030403503503506580100 Double threeway transfer ball valve flexibly coupledFS = Flexible Size (required sizes to be specified)SSppaarree ppaarrttssMMooddeell AA5 Global Filtration TechnologyPos1O-ringO-ringBall SeatO-ringBushingO-ringBack-up RingBushingNBR70 shoreNBR70 shorePTFENBR70 shorePTFENBR70 shorePTFEPTFE 79,5 x 3 104,5 x 3 91,5 x 80 123 x 105 124,5 x 3 152 x 3,53 35 x 30 x18 35 x 30 x18 29,2 x 3 29,2 x 3 35x 30 x1,5 35x 30 x1,5 40,5 x 13,5 40,5 x 13, 84,5 X 3 114.


Related search queries