44-WAY754-Way/2 and 3 Position ValvesFour-ported Valves are generally used to operate double-actingcylinders or actuators . They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder ports providing pressure to the double-acting cylinder or actuator. One or two outlets to exhaust pressure from the cylinder a de-energized Position , pressure is connected to one cylinderport; the other port is connected to the exhaust. In an energizedposition, pressure and exhaust are ports means less piping is required. With five ports, independent speed controls can be mounted in each Types of Constructions ApplySingle SolenoidWhen the solenoid is energized , the valve shifts, then returns to theoriginal Position when de-energized.

4 4-WAY 75 4-Way/2 and 3 Position Valves Four-ported valves are generally used to operate double-acting cylinders or actuators . They have four or five pipe connections, commonly called ports:

Tags:

  Position, Valves, 2 and 3 position valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 4 4-Way/2 and 3 Position Valves - Tri-State Tech

1 44-WAY754-Way/2 and 3 Position ValvesFour-ported Valves are generally used to operate double-actingcylinders or actuators . They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder ports providing pressure to the double-acting cylinder or actuator. One or two outlets to exhaust pressure from the cylinder a de-energized Position , pressure is connected to one cylinderport; the other port is connected to the exhaust. In an energizedposition, pressure and exhaust are ports means less piping is required. With five ports, independent speed controls can be mounted in each Types of Constructions ApplySingle SolenoidWhen the solenoid is energized , the valve shifts, then returns to theoriginal Position when de-energized.

2 Dual Solenoid When one solenoid is energized, the valve shifts, then returnswhen the other solenoid is energized. They may be energizedmomentarily or continu ously, but never concurrently. Somevalves, both single and dual solenoid, may change Position onloss of fluid Air Operator When the operator is pressurized, the valve shifts, then returnswhen the pressure is Engineering Section for further and Optional FeaturesSolenoid Valves are supplied, as listed, with either RedHat II moldedepoxy solenoids or RedHat solenoids with metal enclosures (exceptfor Series 8401). RedHat II Valves are identified by the letter G or H in their catalog numbers; , optional features may be added to your Valves ; , high-temperature ClassH molded coils and manual operators.

3 See the Optional Features Section for and 5-Ported Valves Flow DescriptionPipe Size (NPT)Page8340 Air Only1/4"778342 General Service1/4" and 3/8"818344 Piston/Poppet1/4" - 1"838345 General Service1/4"878401/8402 Slide Valve1/4"898551/8553 Inline Spool Valve1/4" and 1/2"938551/8553 RedHat II Spool Valve 1/4" and 1/2"95 Single SolenoidCyl. BCyl. BCyl. AExh. 2 Cyl. BCyl. AExh. 4 Press. Exh. 2 Cyl. BCyl. AExh. 2 Cyl. BCyl. AExh. 4 Press. Exh. ACyl. ACyl. ACyl. BCyl. ADual SolenoidSingle SolenoidDual SolenoidDe-EnergizedSolenoid A Last EnergizedDe-EnergizedSolenoid A Last EnergizedEnergizedSolenoid B Last EnergizedEnergizedSolenoid B Last EnergizedTypical 4 PortedTypical 5 PortedIndex44-WAY76 Because Time Today delivers the great products you need, when you need them.

4 You save time and money. Just place your order by 3:00 EST and ASCO ships today. Guaranteed same day shipment or ASCO pays the freight ASCO Today includes our most popular Valves , valve rebuild kits, and accessories Over 2000 of ASCO's most popular products qualify for ASCO Today's guarantee Solenoid Valves Miniature Valves Valve Monitoring Systems Pressure SwitchesAs part of our continued drive for customer service, we expanded the ASCO Today program with over 40,000 products that can be shipped within five business days. TMProducts may vary in Canada, please call 1-519-758-2700 to check availability of specific catalog Performance Matters ASCO is Committed to Technology, Leadership, and more information on how you can have the ASCO products you want when you want them, visit us online to see our complete listing of ASCO Today products or call Today is registered in the United ^ )

5 Features Air-only design for cylinder control Up to eight single and dual solenoid Valves , in any combination, can be manifolded Sub-base constructions have separate cylinder connections and common pressure and exhaust connections at each be assembled in the field by simply inserting tie rods through holes in base Group-mounted constructions have common pressure connections at each end and separate cylinder and exhaust connections Can be factory assembled or grouped in the field with strong snap-on clamps, suppliedDirect ActingAir-Only Solenoid ValvesAluminum Body In-Line, Sub-Base, and Group-Mounted1/4" NPTBEAPS olenoid EnclosuresElectricalNominal Ambient Temp. RangesAC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 77 F (0 C to 25 C)(104 F/40 C occasionally)Refer to Engineering Section for leakage rate of 2 SCFH is reducedto a very slight amount as the valve wears certified.

6 AC is UL listed as General PurposeValve. RedHat II meets applicable CE directives. Refer to Engineering Section for :RedHat II - Watertight, Types 1, 2, 3, 3S, 4, and 4X; RedHat - Type : RedHat II - Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9 (For 8340G001 and 8340G002 only); RedHat - Types 3, 4,4X, 7, and 9. (To order, add prefix EF to catalog number.)See Optional Features Section for other available Parts in Contact with Fluids Body Hard Anodized AluminumDiscPECore Tube305 Stainless SteelCore and Plugnut 430F Stainless SteelCore Spring 302 Stainless SteelShading Coil CopperSeals NBRM iscellaneousPA, CAStandardCoil andClass ofInsulationWatt Rating and PowerConsumptionSpare Coil Part NumberDCWattsAC General Purpose Voltages:24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).

7 6, 12, 24, 120, 240 volts DC. Must be specified when voltages available when (Metric units)Specifications (English units)PipeSize(ins.)OrificeSize(ins.)CvF lowFactorOperating PressureDifferential (psi)Max. FluidTemp. FAluminum BodyWatt Rating/Class of CoilInsulation Max. ACMax. DCAir-Inert GasAir-Inert GasACDCC atalog NumberACDCSINGLE VALVE CONSTRUCTION - Single Solenoid1/45 VALVE CONSTRUCTION - Dual Solenoid1/45 MOUNTED CONSTRUCTION - Single Solenoid1/45 MOUNTED CONSTRUCTION - Dual Solenoid1/45 95 MOUNTED CONSTRUCTION - Single Solenoid1/45 MOUNTED CONSTRUCTION - Dual Solenoid1/45 95 Rating shown for individual mounted Valves ; when group mounted, maximum UL allowable fluid and ambient temperature is 86 (ins.)OrificeSize(mm)Kv FlowFactor(m3/h)Operating PressureDifferential (bar)Max.

8 FluidTemp. CAluminum BodyWatt Rating/Class of CoilInsulation Max. ACMax. DCAir-Inert GasAir-Inert GasACDCC atalog NumberACDCSINGLE VALVE CONSTRUCTION - Single Solenoid1 VALVE CONSTRUCTION - Dual Solenoid1 MOUNTED CONSTRUCTION - Single Solenoid1 MOUNTED CONSTRUCTION - Dual Solenoid1 35 MOUNTED CONSTRUCTION - Single Solenoid1 MOUNTED CONSTRUCTION - Dual Solenoid1 35 Rating shown for individual mounted Valves ; when group mounted, maximum UL allowable fluid and ambient temperature is 30 : inches (mm)Single Valve Construction - Single And Dual SolenoidsSub-Base Mounted Single and Dual Solenoid CconstructionNote: Dual solenoid shown dotted : inches (mm) 80 Group-Mounted ConstructionSingle SolenoidGroup-Mounted Construction - Dual SolenoidSub-Base Mounted Construction(Shown As Group-Mounted)Mounting BracketsCatalog Number With General PurposeSolenoid EnclosureWhen ManualOperator is Used8340G001 Mounting Holes on BodyOrder Kit No.

9 206-7378340G002 StandardNA8340A003 Mounting Holes on BodyOrder Kit No. 206-5548340A004 Mounting Holes on BodyNA8340A005 Mounting Holes on BodyNA8340A008 Standard when factory assembled, but must order Kit No. 206-554 for Individual - Not Available8340R14/2 SERIES83424-WAY4% ^ )Features Direct acting operation and high flow construction Direct acting, high flow slide-style valve Optional flow control regulates cylinder speed independently, in either direction Mechanical detent on dual solenoids holds last Position ,even after loss of electric power, pneumatics or pressure No Minimum Operating Pressure Differential required to shift valve Dual solenoid operation: solenoid may be energized momentarily (1/10 second) or continuously Mountable in any positionDirect ActingGeneral Service Solenoid ValvesBrass or Stainless Steel Bodies1/4" and 3/8" NPTBEAPS olenoid EnclosuresNominal Ambient Temp.

10 RangesStandard Class F insulation: 32 F to 125 F (0 C to 52 C) Optional Class H insulation: 32 F to 140 F (0 C to 60 C)Refer to Engineering Section for certified. UL listed as General Purpose applicable CE directives. Refer to Engineering Section for : Watertight, Types 1, 2, 3, 3S, 4, and : Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9. (To order, add prefix EF to catalog number.)See Optional Features Section for other available Parts in Contact with Fluids Body Brass304 Stainless SteelSeals and DiscsNBR and FKMCore Tube 305 Stainless SteelCore and Plugnut430F Stainless SteelSprings 302 Stainless Steel / 17-7 PH Stainless SteelShading CoilCopperSleeve PASeatsGraphite-filled PTFES tandardCoil andClass ofInsulationWatt Rating and PowerConsumptionSpare Coil Part NumberACGeneral Voltages: 24, 120, 240, 480 volts AC, 60 Hz.