Example: bachelor of science

4 Air and Water Solenoid Valves Brass Body • 3/8 …

43/2 SERIES83163-WAY49 AEPNCNOF eatures Diaphragm poppet Valves suitable for controlling air, inert gas, and liquids Internal piloting controls large orifices to provide high flows Can be used to pilot large actuators to provide quick closing of large control Valves Resilient seating for tight shutoff Mountable in any positionPilot OperatedAir and Water Solenoid ValvesBrass body 3/8" to 1" NPTS olenoid EnclosuresNominal Ambient Temp. RangesAC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 104 F (0 C to 40 C)Refer to Engineering Section for certified. Meets applicable CE directives. Refer to Engineering Section for minimum operating pressure differential must bemaintained between the pressure and exhaust and exhaust piping must be full area, flow controls and other similar components mustbe installed in the cylinder lines :Watertight, Types 1, 2, 3, 3S, 4, and :Explosionproof and Watertight, Types 3

4 3/2 SERIES 8316 3-WAY 49 A E P NC NO Features • Diaphragm poppet valves suitable for controlling air, inert gas, and liquids • Internal piloting controls large orifices to …

Tags:

  Water, Valves, Solenoid, Body, Brass, 1863, And water solenoid valves brass body

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 4 Air and Water Solenoid Valves Brass Body • 3/8 …

1 43/2 SERIES83163-WAY49 AEPNCNOF eatures Diaphragm poppet Valves suitable for controlling air, inert gas, and liquids Internal piloting controls large orifices to provide high flows Can be used to pilot large actuators to provide quick closing of large control Valves Resilient seating for tight shutoff Mountable in any positionPilot OperatedAir and Water Solenoid ValvesBrass body 3/8" to 1" NPTS olenoid EnclosuresNominal Ambient Temp. RangesAC: 32 F to 125 F (0 C to 52 C) DC: 32 F to 104 F (0 C to 40 C)Refer to Engineering Section for certified. Meets applicable CE directives. Refer to Engineering Section for minimum operating pressure differential must bemaintained between the pressure and exhaust and exhaust piping must be full area, flow controls and other similar components mustbe installed in the cylinder lines :Watertight, Types 1, 2, 3, 3S, 4, and :Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.

2 (To order, add prefix EF to catalog number.)See Optional Features Section for other available )Valve Parts in Contact with Fluids body Brass Seals and DiscNBRD iaphragm AssemblyNBRCore Tube 305 Stainless SteelCore and Plugnut 430F Stainless SteelCore Springs 302 Stainless Steel and 17-7PH Stainless SteelShading Coil CopperPilot Seat Cartridgeand Disc-Holder CAStandardCoil andClass ofInsulationWatt Rating and PowerConsumptionSpare Coil Part NumberDCWattsACWattsVAHoldingVAInrushGen eral Purpose 238710 238614 238714 Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).

3 6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages available when 8316R13/2 SERIES831643-WAY50 Specifications (Metric units)Specifications (English units)PipeSize(ins.)OrificeSize(ins.)CvF lowFactorOperating PressureDifferential (psi)Max. FluidTemp. FBrass Watt Rating/Class of CoilInsulation Min. Max. ACMax. DCCatalog NumberAir-InertGasWaterAir-InertGasWater ACDCACDCNORMALLY CLOSED (Closed when de-energized)3/85 OPEN (Open when de-energized)3/85 10 psi Minimum Operating Pressure Differential required. Valve vents to "zero" psi. On 50 hertz service, the watt rating for Solenoid is (ins.)

4 OrificeSize(mm)Kv FlowFactor(m3/h)Operating PressureDifferential (bar)Max. FluidTemp. CBrass Watt Rating/Class of CoilInsulation Min. Max. ACMax. DCCatalog NumberAir-InertGasWaterAir-InertGasWater ACDCACDCNORMALLY CLOSED (Closed when de-energized)3 OPEN (Open when de-energized)3 1 bar Minimum Operating Pressure Differential required. Valve vents to "zero" bar. On 50 hertz service, the watt rating for Solenoid is watts. 8316R13/2 SERIES831643-WAY51 Dimensions: inches (mm)Const. Ref. 1,2 8316R13/2 SERIES831643-WAY52 Normally ClosedNormally OpenDe-EnergizedDe-EnergizedEnergizedEne rgizedFLOW DIAGRAMSD imensions: inches (mm)Const.

5 Ref. 3, 4, 8316R1


Related search queries