Example: air traffic controller

4 Optional Features - Lesman

4 OPTIONALFEATURESO ptional Features433EF HT 8210 G002 VMOE xplosionproof EnclosureClass H High-Temperature CoilSeries NumberDesign Change Letter SizeFKM ElastomerManual Operator The Design Change Letter indicates a major design change affecting spare parts kits,rebuild kits, and coils. The correct replacement parts for each change letter are shown in ASCO s Rebuild Kits and Coils to Select and SpecifyNot all Optional Features are appropriate or availablefor all 1 lists the Optional electrical feature prefixesavailable for each RedHat II solenoid and coil. Specifythese Features by adding the indicated prefixes to thevalve catalog those prefixes marked with a or for optionalRedHat electrical Features not covered here, contactyour local ASCO sales 2 lists the suffixes for Optional construction featuresavailable for each valve Series. Specify these Features byadding the indicated suffixes to the valve catalog 2:Suffixes for Optional Construction FeaturesTable 1: Optional RedHat II Electrical FeaturePrefixes (For RedHat Optional electrical Features , contact your local sales office.)

4 OPTIONAL FEATURES Optional Features Electrical 434 Optional Electrical Features Most optional electrical features shown here can be included on ASCO valves approved by UL, FM, and CSA.

Tags:

  Feature, Optional, 4 optional features, 4 optional features optional features

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 4 Optional Features - Lesman

1 4 OPTIONALFEATURESO ptional Features433EF HT 8210 G002 VMOE xplosionproof EnclosureClass H High-Temperature CoilSeries NumberDesign Change Letter SizeFKM ElastomerManual Operator The Design Change Letter indicates a major design change affecting spare parts kits,rebuild kits, and coils. The correct replacement parts for each change letter are shown in ASCO s Rebuild Kits and Coils to Select and SpecifyNot all Optional Features are appropriate or availablefor all 1 lists the Optional electrical feature prefixesavailable for each RedHat II solenoid and coil. Specifythese Features by adding the indicated prefixes to thevalve catalog those prefixes marked with a or for optionalRedHat electrical Features not covered here, contactyour local ASCO sales 2 lists the suffixes for Optional construction featuresavailable for each valve Series. Specify these Features byadding the indicated suffixes to the valve catalog 2:Suffixes for Optional Construction FeaturesTable 1: Optional RedHat II Electrical FeaturePrefixes (For RedHat Optional electrical Features , contact your local sales office.)

2 Electrical FeaturesBasicValveCatalogNumberConstruct ionFeaturesAn example of an ASCO valve catalog numberwith prefixes and suffixes:SUFFIX ISUFFIX IISUFFIX IIICodeSeat/Disc/Etc. MaterialCodeForm of FlowCodeFeatureEEPDM (Ethylene Propylene)F Normally ClosedHW Hot Water ConstructionJCR (Neoprene)G Normally OpenLT Low TemperatureK Air Operated, 3-30 psiU UniversalMMetering DeviceNOxygenMB Mounting BracketQ Long-Life ConstructionMOManual OperatorR ResilientMSScrew Type Manual OperatorTPTFE (Teflon )VH High VacuumVFKM (Viton )VM Medium Vacuum Covered on the pages of the Series in which it is and Viton are registered Trademarks of Dupont I, Division 1 ExplosionproofEVClass I, Division 1 Explosionproof with 316 Stainless Steel Hub and Stainless Steel Base PlateEEClass I, Division 2 General PurposeGPPanel Mount Type 1 General Purpose SolenoidJJunction BoxJPPanel Mount Junction BoxOFOpen Frame Spade and Screw Terminal SolenoidsOPPanel Mount Spade, Screw and DIN Terminal SolenoidsCodeCoilHBClass H - Intermediate Power HCClass H - Battery Charging CoilHTClass H - High TemperatureKBClass H - Intermediate Power - Screw Terminals KCClass H - Battery Charging Circuit - Screw TerminalsKFClass F - High Temperature - Screw TerminalsKHClass H - High Temperature - Screw TerminalsKPClass F - Intermediate Power - Screw TerminalsSCClass F - High Temperature - DIN ConnectionSDClass F - Intermediate Power - DIN ConnectionSFClass F - High Temperature - Spade TerminalsSPClass F - Intermediate Power - Spade Terminals SSClass H - Intermediate Power - Spade TerminalsSTClass H - High Temperature - Spade TerminalsSUClass H - High Temperature - DIN ConnectionSVClass H - Intermediate Power - DIN Connection SWClass H - Battery Charging Circuit - Spade TerminalsCode feature L72 continuous leads XOther special constructionsNote:See chart on next page for specific power and temperature ratings.

3 Optional FeaturesR24 OPTIONALFEATURESO ptional FeaturesElectrical434 Optional Electrical FeaturesMost Optional electrical Features shown here can beincluded on ASCO valves approved by UL, FM, and the options you want by adding the appropriateprefix to the catalog number of the valve you are determine the proper prefix, use the Valve SeriesSpecification Table for the valve you are ordering todetermine its watt rating/class of coil II Solenoid OptionsUsing Table 3, find the desired solenoid option in the leftcolumn and the watt rating/class of coil insulation in thenext column. The choice of prefixes is shown in the nexttwo columns on that line. The first column indicates theprefix if Class F temperature protection is sufficient foryour requirements. The second column provides thedesired solenoid option, plus the higher temperatureprotection of a Class H example, to select an 8262H002 valve with a Class HOpen Frame Spade Terminal Solenoid, assuming thevoltage to be 120 volts AC, 60 Hz: In the Specification Table for Series 8262, the Watt Rating/Class of Coil Insulation is for Catalog Number 8262H002.

4 Using Table 3, find the listing for Open FrameSolenoid with Spade Terminal Coil in the left column. Then, find under AC coils in the next column. Reading across the column headed Class H Coil, you ll find the prefix OFST. To order, specify Catalog Number OFST8262H002, 120/60.(Note:Always include the voltage and frequency.)Table 3: Solenoid Options for RedHat II ValvesSolenoidOption RequiredWatt Rating/Class of InsulationClass FCoilPrefixClass H CoilPrefixACDCG eneral Purpose Solenoid(Standard Valve Construction) Mount Type 1 General Purpose FrameSolenoid with Spade Terminal Mount Solenoid with Spade Terminal Frame Solenoid with Screw Terminal Mount Solenoid with Screw Terminal Box with Spade Terminal Mount Junction Box with Spade Terminal Box with Screw Terminal Mount Junction Box with Screw Terminal Connection Mount DIN Connection FeaturesR24 OPTIONALFEATURESO ptional FeaturesElectrical435 Important Note: One-piece molded epoxy RedHat II solenoids are aunique combination of coil and enclosure.

5 When ordering some RedHat IIoptions, it may be necessary to specify the appropriate catalog numberprefixes for both the enclosure and the 1 General Purpose Solenoids with Class F High-Temperature CoilsEnclosures: Also meet Type 2 Dripproof, Types 3 and 3S Raintight, and Types 4 and 4X Watertight requirements. Supplied standard with 1/2" threaded conduit hub and built-in strain relief for : Insulation system for coil temperatures up to 311 F (155 C). For ambient temperature requirement, refer to specific Series and charts in Engineering Information Section. Suitable for 50 and 60 Hz. Ordering Information:Supplied standard on all RedHat II 1 General Purpose Solenoids with Class H High-Temperature CoilsEnclosures: Same as Class F. Coils: Insulation system suitable for coil temperaturesup to 356 F (180 C). For ambient temperature requirements, refer tospecific Series and charts in Engineering Information Section. Suitable for 50 and 60 Hz.

6 Ordering Information: Depending on wattage, use catalog number prefix HT or HB ( , HT8210H002).Panel Mount Type 1 General Purpose Solenoids with Class F or H High-Temperature CoilsEnclosures: Same as above, but with provision for mounting on a panel (panel not included).Coils: Same as Class F or H Information:For Class F coil, use catalog number prefix GP ( , GP8210G2) and specifyvoltage. For Class H coil, depending onwattage, use catalog number prefix GPHT or GPHB ( , GPHT8210G002)and specify 7 (A, B, C, and D) Explosionproof Solenoids with Class F High-Temperature CoilsEnclosures: Also meets Types 3 and 3S Raintight, Types 4 and 4X Watertight, Types 6 and 6 PSubmersible, and Type 9 (E, F, and G) Dust Ignitionproof requirements. Refer to Engineering Information : Insulation systems suitable for coil temperatures up to 311 F (155 C). For ambient temperature requirements, refer to specific Series charts in Engineering Information Section.

7 Suitable for 50 and 60 Hz. Approvals:UL listed; CSA Information:Use catalog number prefix EF ( , EF8210G002) and specify voltage. UL limitations are 284 F (140 C) for Class F insulation systems and 320 F (160 C) for Class H insulation systems. Can be supplied for 50 Hz at a reduced voltage, which is standard throughout the world; , 120/60, 110 FeaturesR24 OPTIONALFEATURESO ptional FeaturesElectrical436 Type 7 (A, B, C, and D)Explosionproof Solenoids with Class H High-Temperature CoilsEnclosure: Same as Class F Explosionproof Coil: Insulation system suitable for coil temperatures up to 356 F (180 C). For ambient temperature requirements, refer to specific Series and charts in Engineering Information Section. Suitable for 50 and 60 Hz. Approvals:UL listed; CSA :Depending on wattage, usecatalog number prefix EFHT or EFHB ( , EFHT8210G002) and specify 7 (A,B, C, and D)Explosionproof Solenoids with Class F or H High-Temperature CoilsEnclosure: Same as above, but with 316 stainless steel conduit hub and stainless steel base plate.

8 Coils: Same as Class F or H Information:For Class F Coil, use catalog number prefix EV ( , EV8262H220) and specify Class H coil, depending on wattage, usecatalog number prefix EVHT or EVHB ( , EVHT8327G002) and specify 7 (A,B, C, and D)Low PowerSolenoids with Class F DC Surge Suppression CoilsEnclosure: Same as Class F Explosionproof : Built-in surge suppression diodes. Low power Watts. Class F insulation Information:For Surge Suppression coils, use catalognumber prefix EFMF or EVMF ( ,EFMF8314H300), and specify :Surge Suppression coils are onlyavailable for Explosionproof Low Frame Solenoids with Class F or H High-Temperature Spade Terminal Coils Valves with Open Frame solenoid construction are intended for use when a solenoid enclosure is not needed; , mounting in a control cabinet. Same as Class F or H above, but with 1/4" spade terminals. Suitable for 50 and 60 Hz. Ordering Information:For Class F coil, depending on wattage,use catalog number prefix OFSF or OFSP ( , OFSF8210G002) and specifyvoltage.

9 For Class H coil, depending onwattage, use catalog number prefix OFSS or OFST ( , OFST8210G002)and specify :Spade Terminal Coils are not availableabove 250 volts AC or Mount Solenoids with Class F or H High-TemperatureSpade Terminal CoilsSame as above, but with provision for mountingon a panel (panel not included). Ordering Information:For Class F coil, use catalog number prefix OPSF or OPSP ( , OPSF8210G002)and specify voltage. For Class H coil,depending on wattage, use catalog numberprefix OPSS or OPST ( ,OPST8210G002) and specify :Spade Terminal Coils are not availableabove 250 volts AC or DC. UL limitations are 284 F (140 C) for Class F insulation systems and 320 F (160 C) for Class H insulation systems. Can be supplied for 50 Hz at a reduced voltage, which is standard throughout the world; , 120/60, 110 FeaturesR24 OPTIONALFEATURESO ptional FeaturesElectrical437 Open Frame Solenoids with Class F or H High-TemperatureScrew Terminal Coils Valves with Open Frame solenoid construction are intended for use when a solenoid enclosure is not needed; , mounting in a control cabinet.

10 Same as Class F or H above, but with #8 screws terminals. Suitable for 50 and 60 Hz. Ordering Information:For Class F coil, depending on wattage,use catalog number prefix OFKF or OFKP ( , OFKF8210G002) and specifyvoltage. For Class H coil, depending onwattage, use catalog number prefix OFKH or OFKB ( , OFKH8210G002)and specify :Screw Terminal Coils are not availableabove 250 volts AC or Mount Solenoids with Class F or H High-TemperatureScrew Terminal CoilsCoils: Same as above, but with provision for mounting on a panel (panel not included). Ordering Information:For Class F coil, depending on wattage, usecatalog number prefix OPKF or OPKP ( , OPKP8210G002) and specify Class H coil, depending on wattage, usecatalog number prefix OPKH or OPKB ( , OPKH8210G002) and specify : Screw Terminal Coils are not availableabove 250 volts AC or replacementcoil, order coil and kit number Box Solenoids with Class F or H High-TemperatureSpade or Screw Terminal Coils Enclosures meet Type 1 General Purpose, Type 2 Dripproof, Types 3 and 3S Raintight, and Types 4 and 4X Watertight requirements.


Related search queries