Example: bachelor of science

450W, IPX4, Hmax 1.5 m, Hmin 0.19 m Max. Water …

104(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: X 09/18/2006 SAVE THESE INSTRUCTIONSPage 1 intex OWNER S MANUALK rystal Clean Poolwater SystemModel 8221 220 - 230 V~, 50 HzModel 8231 230 - 240 V~, 50 Hz450W, IPX4, Hmax m, Hmin mMax. Water Temperature 35 oCWarning2 Parts Reference3-4 Product Information and Specifications5 Set Up Instructions6-8 salt & Pool Water Volumes9 intex Pools salt Table10 intex Pools Operating Time Table11 Non intex Pools salt Table12 Non intex Pools Operating Time Table12 Operating Instructions13-15 Alarm Codes & LED Code Chart16-17 Stationary Mounting Option17 Maintenance18-20 Long Term Storage20 intex 3-Way Test Strips21 Pool Maintenance and Chemical Definitions 21 Trouble Shooting Guide22-24 General Aquatic Safety24 Limited Warranty25 intex Service Center Locations25 table OF CONTENTSIMPORTANT SAFETY RULEREAD.

Intex Pools Salt Table 10 Intex Pools Operating Time Table 11 Non Intex Pools Salt Table 12 Non Intex Pools Operating Time Table 12 Operating Instructions 13-15 Alarm Codes & LED Code Chart 16-17 Stationary Mounting Option 17 Maintenance 18-20 Long Term Storage 20 INTEX 3 …

Tags:

  Loops, Table, Salt, Intex, Intex pools salt table, Intex pools

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 450W, IPX4, Hmax 1.5 m, Hmin 0.19 m Max. Water …

1 104(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: X 09/18/2006 SAVE THESE INSTRUCTIONSPage 1 intex OWNER S MANUALK rystal Clean Poolwater SystemModel 8221 220 - 230 V~, 50 HzModel 8231 230 - 240 V~, 50 Hz450W, IPX4, Hmax m, Hmin mMax. Water Temperature 35 oCWarning2 Parts Reference3-4 Product Information and Specifications5 Set Up Instructions6-8 salt & Pool Water Volumes9 intex Pools salt Table10 intex Pools Operating Time Table11 Non intex Pools salt Table12 Non intex Pools Operating Time Table12 Operating Instructions13-15 Alarm Codes & LED Code Chart16-17 Stationary Mounting Option17 Maintenance18-20 Long Term Storage20 intex 3-Way Test Strips21 Pool Maintenance and Chemical Definitions 21 Trouble Shooting Guide22-24 General Aquatic Safety24 Limited Warranty25 intex Service Center Locations25 table OF CONTENTSIMPORTANT SAFETY RULEREAD.

2 UNDERSTAND AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLINGAND USING THIS in China 2006 intex Recreation Trading intex (HongKong) Trading O. Box nr. 1075-4700 BB Roosendaal104**-R0-0709104(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: X 09/18/2006 SAVE THESE INSTRUCTIONSPage 2 This Saltwater System/Filter Pump is intended to be used only for the purposes described in this manual. Failure to follow all product, package and package insert safety and installation instructionscould result in property damage, electric shock, entanglement or other serious injury or AND FOLLOW ALL INSTRUCTIONS To reduce the risk of injury, do not permit children to use this product. Always supervise children and those with disabilities.

3 Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a portable residual current device (PRCD). Do not bury electrical cord. Locate cord where it will not be damaged by lawn mowers, hedge trimmers, and other equipment. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or converter plugs to connect unit to electric supply; provide a properly located outlet.

4 Assembly and disassembly by adults only. Do not attempt to plug in or unplug this product while standing in Water or when your hands are wet. Children must stay away from this product and all electrical cords. Do not operate this product when pool is occupied. Always unplug this product from the electrical outlet before cleaning and servicing. This product is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. Keep this product more than 2m away from the pool. Keep this product more than away from the pool (for France only). Keep the plug of this product more than away from the pool.

5 The plug shall be accessible after product TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY DAMAGE, ELECTRICSHOCK, ENTANGLEMENT OR OTHER SERIOUS INJURY OR , Understand and Follow All Instructions Carefully Before Installing and Using this SAFETY RULEThe product warnings, instructions and safety rules provided with this product represent some of thecommon risks associated with Water recreation appliances and do not cover all instances of risk ordanger. Please use common sense and good judgement when enjoying any Water Portable, Above-The-Ground Pools OnlyREF. QTY. REMARK05CG-01 Electrolytic Cell (with Titanium Plates) 105CG-02O-Ring A (pre-installed in 05CG-01)105CG-03 Screw205CG-04 Flow Sensor105CG-05O-Ring B (pre-installed in 05CG-06) 105CG-06 Flow Sensor Conduit105CG-07O-Ring C (pre-installed in 05CG-06)105CG-08 Debris Screen105CG-14 Angle Joint105CG-15O-Ring D (pre-installed in 05CG-14)15F12 Air Release Valve/Sediment Release Valve25F13 Valve O-Ring26F14 Filter Housing Cover16F15 Filter Housing O-Ring16F16 Threaded Filter Housing Collar15NF32 Pump Hose with nuts259905 Filter Cartridge105F-37 Air Release Valve B (with o-ring)105F-38 Water Transfer Hose (with collar and 2 hose clamps)1104(104)

6 ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: X 09/18/2006 SAVE THESE INSTRUCTIONSPage 3 Before assembling your product, please take a few minutes to check the contents and become familiarwith all the REFERENCE5F1205F-3705CG-0305F-385NF3205C G-0205CG-0105CG-0505CG-0605CG-0805CG-14 CELL HOUSINGRECEPTACLEELECTROLYTIC CELLLINE CORDPOWER CORD5F136F165F1305CG-0405CG-1505CG-075F1 2 FLOW SENSORLINE CORD6F146F155NF32 Water FROMPOOLWATER TOPOOL59905104(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: X 09/18/2006 SAVE THESE INSTRUCTIONSPage 4 REF. QTY. REMARK5F01 Strainer Grid06NF-02 Threaded Strainer Connector5F03 Flat Strainer Rubber Washer5F04 Strainer Nut06NF-05 Step Washer5F11 Hose O-Ring06NF-30 Plunger Valve (06NF-05 & 5F11 included)25F31 Large Strainer (5F01/03/04 & 06NF-02)2 For 18 and above Pools05CG-12 Adaptor B2 For 16 and below PoolsF12 Strainer2 For 16 and below Pools5F11 LINER06NF-3006NF-055F0405CG-125F0306NF-0 25F01 PARTS REFERENCE (CONT.)

7 F12104(104) ENGLISH SALTWATER SYSTEM/FILTER PUMP MODEL8221/8231 SIZE: X 09/18/2006 SAVE THESE INSTRUCTIONSPage 5 Product Information and SpecificationsHow the Chlorine is GeneratedCommon salt (sodium chloride) is made up of two elements, sodium and chloride. During the installation ofyour Saltwater System/Filter Pump, a measured quantity of salt is dissolved in the pool Water to make itslightly salty. This pool Water is passed through the Saltwater System s electrolytic cell to produce chlorinewhich is dissolved instantly in the Water . The chlorine instantly starts to destroy bacteria, viruses, algae andoxidizes other organic Saltwater System Parts: Power SupplyThe power supply converts AC electrical current to a low voltage DC current.

8 This is required by the cell to perform the electrolysis that creates chlorine. Electrolytic Cell (with Titanium Plates)The electrolytic cell contains bipolar titanium electrodes which perform the electrolysis and produce liquidchlorine when energized with DC electricity. Chlorine is generated when pool Water containing salt passes through the cell. The chlorine production can be varied by changing the number of hours the Saltwater System is operating each day. The Saltwater System has a built-in self cleaning cycle that operates every two hours without interrupting chlorine production. Flow SensorThe flow sensor protects the electrolytic cell and ensures there is adequate Water flowing through the cell. When the Water flow drops below minimum flow rate, the electrolytic cell will automatically shut down to protect the titanium plates.

9 A safety buzzer will sound and the LED display panel will show a signal code (see LED Code Chart ) indicating the problem. Electronic Control StationThe electronic control station contains an LED display panel and a set of pushbuttons to program the Saltwater System operating hours. It also monitors the different parameters such as salt level, Water flow and the electrolytic cell activity. If any deviation from the norm occurs then a buzzer will sound and the LED display panel will show a signal code (see LED Code Chart ) indicating the SPECIFICATIONSW attage:450 WIdeal salt Level:3000 ppm (parts per million)Maximum Chlorine Output/hour:24 grams/hourLimited Warranty:1 Year (see Limited Warranty ) Water OutletWater InletFlow SensorElectronicControl StationElectrolytic Cell (with TitaniumPlates)IMPORTANT:The Saltwater System/Filter Pump must be installed as the last piece of pool equipment in the Water return line to the pool.

10 This location extends the life of the titanium & Plunger Valve Set Up (16 and below AGP)The Saltwater System/Filter Pump assembly includes two (2) strainer-control mechanisms that are tobe installed in the pool liner's two (2) protruding hose connections with adaptor B. The strainer gridprevents large objects from jamming and/or damaging the filter pump and the plunger valve assemblyprevents Water from flowing into the filter pump while the filter cartridge is being placed or the strainer and plunger valve before inflating the pool liner top Grasp the strainer and plunger valve In a counter-clockwise motion unscrew plunger valve union from the threaded strainer connector (06NF-02). Be careful not to lose the step rubber washer (06NF-05).