Example: barber

4C+E PVC Circular CABLE DESIGN - Prysmian …

CABLE CharacteristicsCable DesignPrysmian Australia Pty Ltd | Ph: 1300 300 304 | Fx: 1300 300 307 | E-mail: | New Zealand Ltd | Ph: (09) 827 3109 | Toll Free: 0800 492 225 | E-mail: | All rights reser ved by Pr ysmian Group 2016 | 09 All sizes and values without tolerances are reference values. Speci cations are for product as supplied by Pr ysmian Group: any modi cation or alteration afterwards of product may give di erent result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Pr ysmian Group. The information is believed to be correct at the time of issue. Pr ysmian Group reser ves the right to amend this speci cation without prior notice. This speci cation is not contractually valid unless speci cally authorised by Pr ysmian XLPE CABLES kVX-90 XLPE INSULATED LAID UP AND PVC SHEATHED CABLE TO AS/NZS For mains, submains and subcircuits unenclosed, in conduit, buried or in underground ducts for buildings and industrial plants where not subject to mechanical damage and where out of balance currents may require a neutral equal in size to the active.

Cable Characteristics Cable Design Prysmian Australia Pty Ltd | Ph: 1300 300 304 | Fx: 1300 300 307 | E-mail: sales.au@prysmiangroup.com | www.prysmiancable.com.au

Tags:

  Design, Cable, Circular, Prysmian, Pvc circular cable design, Cable design prysmian

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of 4C+E PVC Circular CABLE DESIGN - Prysmian …

1 CABLE CharacteristicsCable DesignPrysmian Australia Pty Ltd | Ph: 1300 300 304 | Fx: 1300 300 307 | E-mail: | New Zealand Ltd | Ph: (09) 827 3109 | Toll Free: 0800 492 225 | E-mail: | All rights reser ved by Pr ysmian Group 2016 | 09 All sizes and values without tolerances are reference values. Speci cations are for product as supplied by Pr ysmian Group: any modi cation or alteration afterwards of product may give di erent result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Pr ysmian Group. The information is believed to be correct at the time of issue. Pr ysmian Group reser ves the right to amend this speci cation without prior notice. This speci cation is not contractually valid unless speci cally authorised by Pr ysmian XLPE CABLES kVX-90 XLPE INSULATED LAID UP AND PVC SHEATHED CABLE TO AS/NZS For mains, submains and subcircuits unenclosed, in conduit, buried or in underground ducts for buildings and industrial plants where not subject to mechanical damage and where out of balance currents may require a neutral equal in size to the active.

2 Suitable where space is at a premium and/or where conditions of overload may Conditions4C+E XLPE CIRCULARCONDUCTOR:Plain annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 90 CINSULATION:X-90 XLPE Colours: Red, White, Blue, Black, GreenSHEATH:5V-90 PVC Colours: Orange+90 C-15 C1 GoodWaterDropsGoodC3 Semi-rigidOD 25 4 DOD>25 6D0 CINDUSTRIALEQUIPMENTINCONDUITMACHINESOD 25 6 DOD>25 9 DIN FREE AIRIN TRENCHIN GROUND WITH PROTECTIONIN DUCTEXTERNALBUILDING CONSTRUCTION PVC CABLES / 1 kV 4C+E PVC Circular PVC INSULATED LAID UP AND PVC SHEATHED CABLE TO AS/NZS CABLE CHARACTERISTICS Semi-rigidOD 25 4 DOD>25 6D1 WaterDropsGood+75 C -15 CC3 GoodFor mains, submains and subcircuits unenclosed, in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage and where out of balance currents may require a neutral equal in size to the active.

3 CABLE DESIGNCONDUCTOR:Plain annealed copper conductor to AS/NZS 1125 Maximum continuous operating temperature: 75 C Can also be operated at temperatures up to 90 C when not exposed to mechanical deformation (see AS/NZS 3008)INSULATION:V-90 PVCC olours: Red, White, Blue, Black, Green/YellowSHEATH:5V-90 PVCC olours: OrangeINSTALLATION CONDITIONSINDUSTRIALEQUIPMENTOD 25 6 DOD>25 9 DIN FREEAIRINCONDUITMACHINES0 CIN TRENCHIN GROUND WITHPROTECTIONIN DUCTEXTERNALBUILDINGS . Physical & Electrical CharacteristicsPrysmian Australia Pty Ltd | Ph: 1300 300 304 | Fx: 1300 300 307 | E-mail: | New Zealand Ltd | Ph: (09) 827 3109 | Toll Free: 0800 492 225 | E-mail: | All rights reser ved by Pr ysmian Group 2016 | 09 All sizes and values without tolerances are reference values.

4 Speci cations are for product as supplied by Pr ysmian Group: any modi cation or alteration afterwards of product may give di erent result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Pr ysmian Group. The information is believed to be correct at the time of issue. Pr ysmian Group reser ves the right to amend this speci cation without prior notice. This speci cation is not contractually valid unless speci cally authorised by Pr ysmian XLPE CABLES kV 4C+E XLPE CIRCULARP roduct codeConductorCableMin. installed bending Number anddiameter of wiresNo/mmNominaldiametermmNominalinsula tionthicknessmmOverall diameter mmApprox. mass kg/100 mMinimumMaximum254 CEXLP2519 7. 3328220954 CEXLP9519 7/ 7/ 2. 5 21 7. 7. Current rating (a)Electrical characteristicsUnenclosedspacedABurieddi rectAUndergroundin ductAMaximum at 20 C /kmReactance per core (a) Based on 90 C conductor temperature, 40 C ambient air temperature and where applicable, burial depth of m, soil temperature of 25 C and soil thermal resistivity of Refer to AS/NZS for other installation Australia Pty Ltd | Ph: 1300 300 304 | Fx: 1300 300 307 | E-mail: | New Zealand Ltd | Ph: (09) 827 3109 | Toll Free: 0800 492 225 | E-mail: | All rights reser ved by Pr ysmian Group 2016 | 09 All sizes and values without tolerances are reference values.

5 Speci cations are for product as supplied by Pr ysmian Group: any modi cation or alteration afterwards of product may give di erent result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Pr ysmian Group. The information is believed to be correct at the time of issue. Pr ysmian Group reser ves the right to amend this speci cation without prior notice. This speci cation is not contractually valid unless speci cally authorised by Pr ysmian Usage CharacteristicsCABLE HANDLINGL aying ConditionsMINIMUM BENDING RADIUS DURING INSTALLATIONMIN. INSTALLATIONTEMPERATUREINTERNALWIRINGIN FREE AIRINDUSTRIALEQUIPMENTIN GROUND WITH PROTECTIONEXTERNALBUILDINGIN TRENCHIN GROUNDIN DUCTDOMESTIC APPLIANCESMACHINESMOBILE EQUIPMENTIN CONDUITSUBMERGEDOUTDOORAPPLIANCESOVERHEA D AERIALFESTOONAMBIENT TEMPERATUREM aximum operating temperatureMinimum operating temperatureHALOGEN FREEAS/NZS 4507 MINIMUM BENDING RADIUSM inimum bending radius of installed cablesMECHANICAL IMPACT RESISTANCE1 Light Impact2 Moderate Impact3 Heavy Impact4 Very Heavy ImpactRESISTANCE TO SOLAR RADIATION AND WEATHERE xcellentPermanentVery GoodFrequentGoodOccasionalAcceptableAcci dentalPoorNoneFLEXIBILITYR igidFlexibleSemi-rigidVery flexibleLOW SMOKE EMISSIONAS/NZS 4507 CHEMICAL RESISTANCEE xcellentPermanentVery GoodFrequentGoodOccasionalAcceptableAcci dentalPoorNoneBEHAVIOUR IN FLAME AND FIRER eaction To FireResistant To FireC 1 Fire retardantLevel 1

6 Ultimate fire survivalC 2 Flame retardantLevel 2 Two hours fire survivalC 3 No fire performanceLevel 3 Restrained spread & self extinguishingRESISTANCE TO WATERN egligibleNo humidityWater DropsOccasional condensationSprayWater run offSplashesExposed to water splashesHeavy SeaExposed to wavesImmersionTemporarily covered by waterSubmersionPermanently covered by water